Multidetector computed tomography study to measure thoracic aorta diameters in Egyptian population

被引:0
|
作者
Ismail, Ahmed Shehata Mohamed [1 ]
Al-Suraimi, Shareefa Ali Mohammad [1 ]
El Hossary, Hossam El Din Ghanem [1 ]
Salem, Mohamed Ali [1 ]
Kandil, Hossam Ibrahim Hamed [1 ]
机构
[1] Cairo Univ, Giza, Egypt
来源
EGYPTIAN HEART JOURNAL | 2021年 / 73卷 / 01期
关键词
Thoracic aortic diameter; MSCT aortography; Aorta; Multi-slice CT; Aortography; REFERENCE VALUES;
D O I
10.1186/s43044-021-00216-y
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The aorta is the largest and strongest artery in the body that plays an important role in the control of systemic vascular resistance and heart rate. Aortic diseases contribute to the wide spectrum of arterial diseases that may be diagnosed after a long period of subclinical development. Multidetector computed tomographic scanners (>= 64 detector rows) for aortic imaging remain one of the most preferred imaging techniques for diagnosis and follow-up of aortic conditions in acute as well as chronic presentations. The aim of this study is to establish a normal reference values for aortic diameters among Egyptian population and to find which of the cardiovascular risk factors could be an independent determinant of the aortic diameters. Results: Five hundred and sixteen Egyptian individuals were enrolled in our study, the mean age was 53.5 +/- 10.9, and males comprised 61.4% of the study population. Aortic root diameters measured at the annulus, sinus and STJ were 23.09 +/- 2.55 mm, 33.75 +/- 3.93 mm and 26.13 +/- 3.05 mm, respectively. The BSA-indexed diameters were 11.70 +/- 1.39, 17.10 +/- 2.10 and 13.25 +/- 1.65, respectively. The diameter of the tubular part of ascending aorta was 30.97 +/- 4.16 mm, and the BSA-indexed diameter was 15.71 +/- 2.28. The aortic diameters measured at the level of the pulmonary bifurcation were 24.56 +/- 2.95 mm and 23.79 +/- 2.96 mm at systolic and diastolic phases, respectively. The BSA-indexed diameters were 12.44 +/- 1.52 and 12.05 +/- 1.52 at systolic and diastolic phases, respectively. At the diaphragmatic level, the mean diameters were 22.39 +/- 2.72 mm and 21.49 +/- 2.79 mm at systolic and diastolic phases, respectively. The BSA-indexed diameters were 11.34 +/- 1.43 and 10.98 +/- 1.48 at systolic and diastolic phases, respectively. Age, gender, BSA, BMI and hypertension were statistically significant independent predictors of ascending and descending aortic diameters. Conclusions: Our study established a normal reference value for thoracic aortic diameters among Egyptians using contrast enhanced MSCT aortography. Age, Gender, BSA, BMI and hypertension are the major determinants of aortic diameters.
引用
收藏
页数:19
相关论文
共 50 条
  • [31] DISSECTING ANEURYSM OF THE THORACIC AORTA - VALUE OF COMPUTED-TOMOGRAPHY
    SCHURAWITZKI, H
    IMHOF, H
    GRITZMANN, N
    DIGITALE BILDDIAGNOSTIK, 1986, 6 (02): : 77 - 80
  • [32] Anatomical References to Evaluate Thoracic Aorta Calcium by Computed Tomography
    Jesiana Ferreira Pedrosa
    Sandhi Maria Barreto
    Márcio Sommer Bittencourt
    Antonio Luiz Pinho Ribeiro
    Current Atherosclerosis Reports, 2019, 21
  • [33] DIAGNOSIS OF DISSECTING ANEURYSM OF THORACIC AORTA BY COMPUTED-TOMOGRAPHY
    DOBBELSTEIN, D
    KUCKEIN, D
    HERZ KREISLAUF, 1980, 12 (09): : 387 - 390
  • [34] Automatic segmentation of the thoracic aorta in cardiac computed tomography images
    Vera, Miguel
    Huerfano, Yoleidy
    Contreras, Julio
    Vera, Maria
    Del Mar, Atilio
    Chacon, Jose
    Wilches-Duran, Sandra
    Graterol-Rivas, Modesto
    Riano-Wilches, Daniela
    Rojas, Joselyn
    Bermudez, Valmore
    REVISTA LATINOAMERICANA DE HIPERTENSION, 2016, 11 (04): : 110 - 116
  • [35] COMPUTED-TOMOGRAPHY IN THE DIAGNOSIS OF TRAUMATIC RUPTURE OF THE THORACIC AORTA
    BROOKS, AP
    OLSON, LK
    SHACKFORD, SR
    CLINICAL RADIOLOGY, 1989, 40 (02) : 133 - 138
  • [36] Anatomical References to Evaluate Thoracic Aorta Calcium by Computed Tomography
    Pedrosa, Jesiana Ferreira
    Barreto, Sandhi Maria
    Bittencourt, Marcio Sommer
    Pinho Ribeiro, Antonio Luiz
    CURRENT ATHEROSCLEROSIS REPORTS, 2019, 21 (12)
  • [37] Refined computed tomography of the thoracic aorta: the impact of electrocardiographic assistance
    Morgan-Hughes, GJ
    Marshall, AJ
    Roobottom, CA
    CLINICAL RADIOLOGY, 2003, 58 (08) : 581 - 588
  • [38] AGE-RELATED CHANGE IN CALCIFICATIONS IN THE THORACIC AORTA - A STUDY WITH COMPUTED-TOMOGRAPHY
    TAKEDA, S
    WATANABE, H
    MATSUZAWA, T
    TOHOKU JOURNAL OF EXPERIMENTAL MEDICINE, 1986, 149 (01): : 73 - 78
  • [39] Progression and regression of intramural hematoma of the ascending thoracic aorta: A study by serial computed tomography
    Kaji, S
    Akasaka, T
    Hozumi, T
    Takagi, T
    CIRCULATION, 1998, 98 (17) : 338 - 338
  • [40] Stenotic lesions of aorta: Imaging evaluation using multidetector computed tomography angiography
    Sharma, Arun
    Ojha, Vineeta
    Pandey, Niraj N.
    Sinha, Mumun
    Malhi, Amarinder S.
    Chandrashekhara, S. H.
    Kumar, Sanjeev
    Sharma, Gautam
    ASIAN CARDIOVASCULAR & THORACIC ANNALS, 2021, 29 (09): : 884 - 892