Investigation of cross-coupling in 1-3 piezocomposite arrays

被引:31
|
作者
Certon, D
Felix, N
Lacaze, E
Teston, F
Patat, F
机构
[1] Fac Med Tours, GIP Ultrasons, Lussi, F-37032 Tours, France
[2] Vermon SA, F-37038 Tours, France
关键词
D O I
10.1109/58.895913
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Plate waves inside the piezoelectric layer are much involved in the elements cross-coupling in transducer arrays for medical imaging. In this work, such waves are analyzed in 1-3 piezocomposite materials on the basis of conventional guided modes formalism in which the piezocomposite is considered as a homogeneous medium. Cross-coupling measurements have been made on two different transducer arrays using network analyzer and a laser interferometric probe. It is shown how the analysis in terms of symmetrical Lamb waves gives an interesting qualitative interpretation, explaining most of the cross-coupling amplitude variations with frequency. Results show that the 0th and 3rd symmetrical Lamb waves are mainly involved in coupling inside composite plates. The So mode is responsible for the inter-element coupling, whereas the Ss mode widens the effective width of the excited element.
引用
收藏
页码:85 / 92
页数:8
相关论文
共 50 条
  • [31] Microfabrication of Pb-free piezoceramic microrod arrays and 1-3 type ceramic/polymer piezocomposite films
    Xu, Ying
    Li, Jing-Feng
    MATERIALS LETTERS, 2009, 63 (24-25) : 2119 - 2122
  • [32] 1-3 piezocomposite smart panels for active surface control
    Gentilman, R
    Fiore, D
    PhamNguyen, H
    Serwatka, W
    Pazol, B
    Near, C
    McGuire, P
    Bowen, L
    INDUSTRIAL AND COMMERCIAL APPLICATIONS OF SMART STRUCTURES TECHNOLOGIES - SMART STRUCTURES AND MATERIALS 1996, 1996, 2721 : 234 - 239
  • [33] Experimental and theoretical determination of 1-3 piezocomposite electroacoustic tensor
    Ferin, Guillaume
    Certon, Dominique
    Felix, Nicolas
    Patat, Frederic
    ULTRASONICS, 2006, 44 : E763 - E772
  • [34] Research on Properties of Cymbal Transducer Based on 1-3 Piezocomposite
    Liang, Shuang
    Li, Denghua
    Gao, Xiangyu
    ITESS: 2008 PROCEEDINGS OF INFORMATION TECHNOLOGY AND ENVIRONMENTAL SYSTEM SCIENCES, PT 1, 2008, : 433 - 437
  • [35] CROSS-COUPLING COMPENSATION IN ACOUSTIC ARRAYS BY LATERAL DECONVOLUTION
    JACOVITTI, G
    NERI, A
    PAPPALARDO, M
    IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1983, 30 (03): : 195 - 196
  • [36] Cross-coupling in sealed cMUT arrays for immersion applications
    Campbell, E.
    Davis, L. A. J.
    Hayward, G.
    Hutchins, D.
    2007 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1-6, 2007, : 2135 - +
  • [37] Numerical technique to reduce cross-coupling in acoustical arrays
    Cugnet, B
    Hladky, AC
    Assaad, J
    ULTRASONICS, 2002, 40 (1-8) : 503 - 506
  • [38] The theoretical model of 1-3 piezocomposite transducer with matching layer
    Chao, Zhong
    Wang, Likun
    Lei, Qin
    Sun, Shaoping
    Xing, Li
    FERROELECTRICS, 2020, 554 (01) : 97 - 103
  • [39] Cubane Cross-Coupling and Cubane-Porphyrin Arrays
    Bernhard, Stefan S. R.
    Locke, Gemma M.
    Plunkett, Shane
    Meindl, Alina
    Flanagan, Keith J.
    Senge, Mathias O.
    CHEMISTRY-A EUROPEAN JOURNAL, 2018, 24 (05) : 1026 - 1030
  • [40] A new navy calibration standard transducer using 1-3 piezocomposite
    Benjamin, KC
    Petrie, S
    OCEANS 2000 MTS/IEEE - WHERE MARINE SCIENCE AND TECHNOLOGY MEET, VOLS 1-3, CONFERENCE PROCEEDINGS, 2000, : 1299 - 1304