Study on analogy principle of overall cooling effectiveness for composite cooling structures with impingement and effusion

被引:49
|
作者
Liu, Cun-liang [1 ,2 ]
Xie, Gang [1 ]
Wang, Rui [1 ]
Ye, Lin [1 ]
机构
[1] Northwestern Polytech Univ, Sch Power & Energy, Xian 710072, Shaanxi, Peoples R China
[2] Shaanxi Key Lab Thermal Sci Aeroengine Syst, Xian 710129, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Conjugate heat transfer; Analogy theory; Impingement/effusion plate; Numerical simulation; DENSITY RATIO; PERFORMANCE; FLOW;
D O I
10.1016/j.ijheatmasstransfer.2018.07.085
中图分类号
O414.1 [热力学];
学科分类号
摘要
The overall cooling effectiveness, which represents the distribution of dimensionless temperature on gas turbines surface, is an important parameter for conjugate heat transfer analysis of gas turbines. Generally, it is difficult to measure the overall cooling effectiveness in engine condition. However, the overall cooling effectiveness can be measured in the laboratory by matching the appropriate parameters to those in engine condition. Thus, it is important to evaluate the key parameters of matching methods. In this paper, the effects of adiabatic film effectiveness and Biot number on the overall cooling effectiveness were investigated with an impingement/effusion model by numerical simulation, in which 3-D steady RANS approached with the k-co SST turbulence model was used. The tested plate had 8 cylinder hole rows with 30 degree inclined angle, and the internal cooling employed staggered array jet impingements. The matching performance was evaluated by comparing the results in typical engine condition and laboratory condition. The analogy principles were discussed in detail. The results show that the overall cooling effectiveness can be matched by using suitable matching principle in different lab conditions. The theoretical analysis was verified by numerical results. The distributions and values of overall cooling effectiveness can be matched well between engine condition and lab condition by matching temperature ratio, mainstream side Biot number and blowing ratio. If the temperature ratio is mismatched, the momentum flux ratio will be an important parameter for overall cooling effectiveness, because matching momentum flux ratio can reduce the difference of the adiabatic cooling effectiveness and the heat transfer coefficient ratio between engine condition and laboratory condition. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:639 / 650
页数:12
相关论文
共 50 条
  • [41] Experimental Study on Impingement and Film Overall Cooling Characteristics of Turbine Shroud
    Li, Ziqiang
    Wang, Longfei
    Mao, Junkui
    Bi, Shuai
    Wang, Feilong
    JOURNAL OF THERMAL SCIENCE, 2022, 31 (01) : 239 - 250
  • [42] Experimental Study on Impingement and Film Overall Cooling Characteristics of Turbine Shroud
    LI Ziqiang
    WANG Longfei
    MAO Junkui
    BI Shuai
    WANG Feilong
    Journal of Thermal Science, 2022, (01) : 239 - 250
  • [43] Experimental Study on Impingement and Film Overall Cooling Characteristics of Turbine Shroud
    Ziqiang Li
    Longfei Wang
    Junkui Mao
    Shuai Bi
    Feilong Wang
    Journal of Thermal Science, 2022, 31 : 239 - 250
  • [44] EXPERIMENTAL INVESTIGATION OF OVERALL COOLING EFFECTIVENESS ON COMBUSTION CHAMBER LINER WITH AND WITHOUT IMPINGEMENT HOLES
    Jesuraj, Felix
    Rajendran, Raghavan
    Narayanappa, Kumar Gottekre
    Yepuri, Giridhara Babu
    Sasikumar, Vivek
    Poozhiyil, Sinith
    PROCEEDINGS OF THE ASME GAS TURBINE INDIA CONFERENCE, 2015, 2016,
  • [45] Parametric Studies of Laminated Cooling Configurations: Overall Cooling Effectiveness
    Wang, Chen
    Wang, Chunhua
    Zhang, Jingzhou
    INTERNATIONAL JOURNAL OF AEROSPACE ENGINEERING, 2021, 2021
  • [46] Overall cooling effectiveness of effusion cooled annular combustor liner at reacting flow conditions
    Ji, Yongbin
    Ge, Bing
    Chi, Zhongran
    Zang, Shusheng
    APPLIED THERMAL ENGINEERING, 2018, 130 : 877 - 888
  • [47] Numerical decoupling of the effect of internal cooling and external film cooling on overall cooling effectiveness
    Liu, Runzhou
    Li, Haiwang
    You, Ruquan
    Tao, Zhi
    Huang, Yi
    APPLIED THERMAL ENGINEERING, 2023, 222
  • [48] Study of the effusion wall film heat transfer coefficients of impingement/effusion double wall cooling method
    Xu, Quan-Hong
    Lin, Yu-Zhen
    Liu, Gao-En
    Hangkong Dongli Xuebao/Journal of Aerospace Power, 2004, 19 (02): : 213 - 218
  • [49] DOUBLE WALL COOLING OF A FULL COVERAGE EFFUSION PLATE, INCLUDING INTERNAL IMPINGEMENT ARRAY COOLING
    Ligrani, Phil
    Ren, Zhong
    Liberatore, Federico
    Patel, Rajeshriben
    Srinivasan, Ram
    Ho, Yin-hsiang
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2017 VOL 8, 2018,
  • [50] Local cooling effectiveness distribution of an integrated impingement and pin fin cooling configuration
    Nakamata, Chiyuki
    Mimura, Fujio
    Matsushita, Masahiro
    Yamane, Takashi
    Fukuyama, Yoshitaka
    Yoshida, Toyoaki
    PROCEEDINGS OF THE ASME TURBO EXPO 2007, VOL 4, PTS A AND B, 2007, : 23 - 34