Study on analogy principle of overall cooling effectiveness for composite cooling structures with impingement and effusion

被引:49
|
作者
Liu, Cun-liang [1 ,2 ]
Xie, Gang [1 ]
Wang, Rui [1 ]
Ye, Lin [1 ]
机构
[1] Northwestern Polytech Univ, Sch Power & Energy, Xian 710072, Shaanxi, Peoples R China
[2] Shaanxi Key Lab Thermal Sci Aeroengine Syst, Xian 710129, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Conjugate heat transfer; Analogy theory; Impingement/effusion plate; Numerical simulation; DENSITY RATIO; PERFORMANCE; FLOW;
D O I
10.1016/j.ijheatmasstransfer.2018.07.085
中图分类号
O414.1 [热力学];
学科分类号
摘要
The overall cooling effectiveness, which represents the distribution of dimensionless temperature on gas turbines surface, is an important parameter for conjugate heat transfer analysis of gas turbines. Generally, it is difficult to measure the overall cooling effectiveness in engine condition. However, the overall cooling effectiveness can be measured in the laboratory by matching the appropriate parameters to those in engine condition. Thus, it is important to evaluate the key parameters of matching methods. In this paper, the effects of adiabatic film effectiveness and Biot number on the overall cooling effectiveness were investigated with an impingement/effusion model by numerical simulation, in which 3-D steady RANS approached with the k-co SST turbulence model was used. The tested plate had 8 cylinder hole rows with 30 degree inclined angle, and the internal cooling employed staggered array jet impingements. The matching performance was evaluated by comparing the results in typical engine condition and laboratory condition. The analogy principles were discussed in detail. The results show that the overall cooling effectiveness can be matched by using suitable matching principle in different lab conditions. The theoretical analysis was verified by numerical results. The distributions and values of overall cooling effectiveness can be matched well between engine condition and lab condition by matching temperature ratio, mainstream side Biot number and blowing ratio. If the temperature ratio is mismatched, the momentum flux ratio will be an important parameter for overall cooling effectiveness, because matching momentum flux ratio can reduce the difference of the adiabatic cooling effectiveness and the heat transfer coefficient ratio between engine condition and laboratory condition. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:639 / 650
页数:12
相关论文
共 50 条
  • [1] EXPERIMENTAL STUDY ON ANALOGY PRINCIPLE OF OVERALL COOLING EFFECTIVENESS FOR COMPOSITE COOLING STRUCTURES WITH BOTH INTERNAL COOLING AND FILM COOLING
    Xie, Gang
    Liu, Cun-liang
    Wang, Rui
    Ye, Lin
    Niu, Jiajia
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, 2019, VOL 5A, 2019,
  • [2] Effects of impingement gap and hole arrangement on overall cooling effectiveness for impingement/effusion cooling
    Xie, Gang
    Liu, Cun-liang
    Ye, Lin
    Wang, Rui
    Niu, Jiajia
    Zhai, Yingni
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 152
  • [3] Experimental investigation on analogy principle of conjugate heat transfer for effusion/impingement cooling
    Xie, Gang
    Liu, Cun-liang
    Niu, Jiajia
    Ye, Lin
    Wang, Rui
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 147
  • [4] NUMERICAL STUDY ON ANALOGY PRINCIPLE OF OVERALL COOLING EFFECTIVENESS IN ENGINE AND LABORATORY CONDITION
    Xie, Gang
    Liu, Cun-liang
    Ye, Lin
    Wang, Rui
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, 2018, VOL 5A, 2018,
  • [5] Experimental Study on the Overall Cooling Effectiveness of Effusion-Cooling Ceramic Matrix Composite Platform
    Du, Kun
    Chen, Qihao
    Huang, Xiaoyang
    Liang, Tingrui
    Liu, Cunliang
    JOURNAL OF THERMAL SCIENCE, 2023, 32 (03) : 1034 - 1048
  • [6] Experimental Study on the Overall Cooling Effectiveness of Effusion-Cooling Ceramic Matrix Composite Platform
    DU Kun
    CHEN Qihao
    HUANG Xiaoyang
    LIANG Tingrui
    LIU Cunliang
    Journal of Thermal Science, 2023, 32 (03) : 1034 - 1048
  • [7] Experimental Study on the Overall Cooling Effectiveness of Effusion-Cooling Ceramic Matrix Composite Platform
    Kun Du
    Qihao Chen
    Xiaoyang Huang
    Tingrui Liang
    Cunliang Liu
    Journal of Thermal Science, 2023, 32 : 1034 - 1048
  • [8] Numerical Study on the Analogy Principle of the Overall Cooling Effectiveness for the Hot Components With Large Curvature
    Du, Kun
    Liang, Tingtui
    Song, Hui
    Liu, Cunliang
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2024, 45 (05): : 1332 - 1340
  • [9] Numerical analysis on multiple parameters for overall cooling effectiveness of impingement effusion cooling with low Reynolds number
    Zhang, Dingcheng
    Liu, Haibin
    Chen, Pingting
    Mao, Junkui
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2024, 153