摘要
An optimization of the undulator layout of X-ray free-electron-laser (FEL) facilities based on placing small chicanes between the undulator modules is presented. The installation of magnetic chicanes offers the following benefits with respect to state-of-the-art FEL facilities: reduction of the required undulator length to achieve FEL saturation, improvement of the longitudinal coherence of the FEL pulses, and the ability to produce shorter FEL pulses with higher power levels. Numerical simulations performed for the soft X-ray beamline of the SwissFEL facility show that optimizing the advantages of the layout requires shorter undulator modules than the standard ones. This proposal allows a very compact undulator beamline that produces fully coherent FEL pulses and it makes possible new kinds of experiments that require very short and high-power FEL pulses.
引用
收藏
页码:861 / 868
页数:8
相关论文
共 50 条
  • [31] Status and future of the soft X-ray free-electron laser beamline at the SHINE
    Liu, Tao
    Huang, Nanshun
    Yang, Hanxiang
    Qi, Zheng
    Zhang, Kaiqing
    Gao, Zhangfeng
    Chen, Si
    Feng, Chao
    Zhang, Wei
    Luo, Hang
    Fu, Xiaoxi
    Liu, He
    Faatz, Bart
    Deng, Haixiao
    Liu, Bo
    Wang, Dong
    Zhao, Zhentang
    FRONTIERS IN PHYSICS, 2023, 11
  • [32] Analysis of the X-ray Free-electron Laser Parameter and Determination of the Optimal Electron Energy and Undulator
    Lee, Tae-Yeon
    Lee, Hee Seock
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2013, 63 (09) : 1728 - 1730
  • [33] Analysis of the X-ray free-electron laser parameter and determination of the optimal electron energy and undulator
    Tae-Yeon Lee
    Hee Seock Lee
    Journal of the Korean Physical Society, 2013, 63 : 1728 - 1730
  • [34] Simple Method to Generate Terawatt-Attosecond X-Ray Free-Electron-Laser Pulses
    Prat, Eduard
    Reiche, Sven
    PHYSICAL REVIEW LETTERS, 2015, 114 (24)
  • [35] Hydrodynamics and detailed atomic physics treatment of x-ray free-electron-laser interaction with matter
    Peyrusse, O.
    DAMAGE TO VUV, EUV, AND X-RAY OPTICS IV; AND EUV AND X-RAY OPTICS: SYNERGY BETWEEN LABORATORY AND SPACE III, 2013, 8777
  • [36] Soft-x-ray free-electron-laser interaction with materials
    Hau-Riege, Stefan P.
    London, Richard A.
    Chapman, Henry N.
    Bergh, Magnus
    PHYSICAL REVIEW E, 2007, 76 (04):
  • [37] Determining electronic damage to biomolecular structures in x-ray free-electron-laser imaging experiments
    Curwood, E. K.
    Quiney, H. M.
    Nugent, K. A.
    PHYSICAL REVIEW A, 2013, 87 (05)
  • [38] X-ray focusing test and x-ray imaging test by a microcapillary x-ray lens at an undulator beamline
    Kohmura, Y
    Awaji, M
    Suzuki, Y
    Ishikawa, T
    Dudchik, YI
    Kolchevsky, NN
    Komarov, FF
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (11): : 4161 - 4167
  • [39] SOFT-X-RAY FREE-ELECTRON LASER WITH A LASER UNDULATOR
    GEABANACLOCHE, J
    MOORE, GT
    SCHLICHER, RR
    SCULLY, MO
    WALTHER, H
    IEEE JOURNAL OF QUANTUM ELECTRONICS, 1987, 23 (09) : 1558 - 1570
  • [40] UNDULATOR SOURCE BEAMLINE FOR SOFT X-RAY IMAGING.
    Rarback, H.
    Krinsky, S.
    Mortazavi, P.
    Shu, D.
    Kirz, J.
    Jacobsen, C.
    Howells, M.
    Nuclear instruments and methods in physics research, 1985, A246 (1-3): : 159 - 162