Dose Reduction and Image Quality in Photon-counting Detector High-resolution Computed Tomography of the Chest Routine Clinical Data

被引:46
|
作者
Graafen, Dirk [1 ]
Emrich, Tilman [3 ,4 ]
Halfmann, Moritz C. [1 ,3 ]
Mildenberger, Peter [1 ]
Dueber, Christoph [1 ]
Yang, Yang [1 ]
Othman, Ahmed E. [2 ]
O' Doherty, Jim [5 ]
Mueller, Lukas [1 ]
Kloeckner, Roman [1 ]
机构
[1] Johannes Gutenberg Univ Mainz, Univ Med Ctr, Dept Diagnost & Intervent Radiol, Langenbeckst 1, D-55131 Mainz, Germany
[2] Johannes Gutenberg Univ Mainz, Univ Med Ctr, Dept Neuroradiol, Mainz, Germany
[3] German Ctr Cardiovasc Res DZHK, Partner Site Rhine Main, Mainz, Germany
[4] Med Univ South Carolina, Div Cardiovasc Imaging, Dept Radiol & Radiol Sci, Charleston, SC 29425 USA
[5] Siemens Med Solut, Malvern, PA USA
关键词
high-resolution computed tomography; photon-counting detector; tin filtration; dose reduction; CT; FEASIBILITY;
D O I
10.1097/RTI.0000000000000661
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Photon-counting detector computed tomography (PCD-CT) has the potential to significantly improve CT imaging in many ways including, but not limited to, low-dose high-resolution CT (HRCT) of the lung. The aim of this study was to perform an intrapatient comparison of the radiation dose and image quality of PCD-CT compared with conventional energy-integrating detector CT (EID-CT). Methods: A total of 32 consecutive patients with available PCD-CT and EID-CT HRCT scans were included in the final analysis. The CT dose index (CTDIvol) was extracted from patient dose reports. Qualitative image analysis comprised the lung parenchyma and mediastinal structures and was assessed by 3 readers using a 5-point Likert scale. Quantitative image analysis included assessment of noise and signal-to-noise ratio in the lung parenchyma, trachea, aorta, muscle, and background. Results: The mean CTDIvol was 2.0 times higher in the conventional EID-CT scans (1.8 +/- 0.5 mGy) compared with PCD-CT (0.9 +/- 0.5 mGy, P<0.001). The overall image quality was rated significantly better by all 3 raters (P<0.001) in the PCD-CT relative to the EID-CT. Quantitative analysis showed no significant differences in noise and signal-to-noise ratio in the lung parenchyma between PCD-CT and EID-CT. Conclusion: Compared with conventional EID-CT scans, PCD-CT demonstrated similar or better objective and subjective image quality at significantly reduced dose levels in an intrapatient comparison. These results and their effect on clinical decision-making should be further investigated in prospective studies.
引用
收藏
页码:315 / 322
页数:8
相关论文
共 50 条
  • [41] Investigating the Effects of Reconstruction Conditions on Image Quality and Radiomic Analysis in Photon-counting Computed Tomography
    Ohata, Miyu
    Fukui, Ryohei
    Morimitsu, Yusuke
    Kobayashi, Daichi
    Yamauchi, Takatsugu
    Akagi, Noriaki
    Honda, Mitsugi
    Hayashi, Aiko
    Hasegawa, Koshi
    Kida, Katsuhiro
    Goto, Sachiko
    Hiraki, Takao
    JOURNAL OF MEDICAL PHYSICS, 2025, 50 (01) : 100 - 107
  • [42] Photon-counting detector computed tomography Paradigm shift in cardiac CT imaging
    Kravchenko, Dmitrij
    Layer, Yannik Christian
    Vecsey-Nagy, Milan
    Tremamunno, Giuseppe
    Varga-Szemes, Akos
    Schlett, Christopher L.
    Bamberg, Fabian
    Emrich, Tilman
    Hagar, Muhammad Taha
    RADIOLOGIE, 2024, 64 (12): : 928 - 934
  • [43] Accuracy of photon-counting computed tomography for the measurement of bone quality in the knee
    Azari, Fahimeh
    Uniyal, Piyush
    Soete, Jeroen
    Coudyzer, Walter
    Wyers, Caroline E.
    Quintiens, Jilmen
    van den Bergh, Joop P.
    van Lenthe, Harry
    BONE, 2024, 181
  • [44] Lung Cancer Screening Using Clinical Photon-Counting Detector Computed Tomography and Energy-Integrating-Detector Computed Tomography: A Prospective Patient Study
    Inoue, Akitoshi
    Johnson, Tucker F.
    Walkoff, Lara A.
    Levin, David L.
    Hartman, Thomas E.
    Burke, Kristin A.
    Rajendran, Kishore
    Yu, Lifeng
    McCollough, Cynthia H.
    Fletcher, Joel G.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2023, 47 (02) : 229 - 235
  • [45] Photon-Counting Detector Computed Tomography Versus Energy-Integrating Detector Computed Tomography for Coronary Artery Calcium Quantitation
    McCollough, Cynthia H.
    Winfree, Tim N.
    Melka, Elnata F.
    Rajendran, Kishore
    Carter, Rickey E.
    Leng, Shuai
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2024, 48 (02) : 212 - 216
  • [46] Influence of Threshold Calibration On CT Image Quality of a Photon-Counting Detector
    Rodesch, P.
    Richtsmeier, D.
    Zalavari, L.
    Bazalova-Carter, M.
    MEDICAL PHYSICS, 2022, 49 (06) : E174 - E174
  • [47] Low-dose high-resolution chest CT in adults with cystic fibrosis: intraindividual comparison between photon-counting and energy-integrating detector CT
    Frings, Marko
    Welsner, Matthias
    Mousa, Christin
    Zensen, Sebastian
    Salhoefer, Luca
    Meetschen, Mathias
    Beck, Nikolas
    Bos, Denise
    Westhoelter, Dirk
    Wienker, Johannes
    Taube, Christian
    Umutlu, Lale
    Schaarschmidt, Benedikt M.
    Forsting, Michael
    Haubold, Johannes
    Sutharsan, Sivagurunathan
    Opitz, Marcel
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2024, 8 (01)
  • [48] Innovative advances in pediatric radiology: computed tomography reconstruction techniques, photon-counting detector computed tomography, and beyond
    Mese, Ismail
    Mese, Ceren Altintas
    Demirsoy, Ugur
    Anik, Yonca
    PEDIATRIC RADIOLOGY, 2024, 54 (01) : 1 - 11
  • [49] Comparison of cone-beam computed tomography with photon-counting detector computed tomography for dental implant surgery
    Husain, Adib Al-Haj
    Mergen, Victor
    Valdec, Silvio
    Husain, Nadin Al-Haj
    Stadlinger, Bernd
    Essig, Harald
    Frauenfelder, Thomas
    Kessler, Peter
    Lie, Suen An Nynke
    Alkadhi, Hatem
    Winklhofer, Sebastian
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2025, 11 (01)
  • [50] Innovative advances in pediatric radiology: computed tomography reconstruction techniques, photon-counting detector computed tomography, and beyond
    Ismail Mese
    Ceren Altintas Mese
    Ugur Demirsoy
    Yonca Anik
    Pediatric Radiology, 2024, 54 : 1 - 11