Effects of Prosthesis Stem Materials on Stress Distribution of Total Hip Replacement

被引:2
|
作者
Abdullah, Abdul Halim [1 ]
Saman, Alias Mohd [1 ]
Nor, Mohd Asri Mohd [1 ]
Taib, Ishkrizat [2 ]
Tardan, Giha [3 ]
机构
[1] Univ Teknol MARA UiTM Malaysia, Fac Mech Engn, Shah Alam 40450, Selangor, Malaysia
[2] Univ Tun Hussien Onn Malaysia UTHM, Fac Mech & Mfg, Batu Pahat 86400, Johor, Malaysia
[3] Minist Higher Educ, Politekn Sultan Salahuddin Abdul Aziz Shah, Dept Mech Engn, Selangor 40150, Malaysia
关键词
Finite Element Method; Biomechanics; Total Hip Replacement; Prosthesis Stem Material; Stress Analysis;
D O I
10.4028/www.scientific.net/AMR.129-131.343
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Bone loss and bone thickening phenomenon occurred due to different stiffness of the implant and femur. Implant with stiffer materials than the bone carries majority of the load and it transferred down along the implant till the distal tip of the stem. Both phenomenons contribute to stress shielding and loosening of the prosthesis stem. In this study, the stress distributions in intact femur and THR femur are established using finite element method. The THR femur model consists of cemented hip Ti6AI4V and CoCrMo prosthesis stem implanted inside the femur bone. Effects of different material properties of the prosthesis stem on the resulting stress distributions are investigated. Results shows that the largest discrepancy in stress values between intact and THR femur is predicted along the middle region at both lateral and medial planes. The distal region shows that the calculated stress for both THR femur experienced higher stress magnitude than that of intact femur. The higher stress in THR femur leads to bone thickening at the particular region. The corresponding stress magnitude saturates at 25 MPa for THR femur while intact femur is slightly lower at 22 MPa.
引用
收藏
页码:343 / +
页数:2
相关论文
共 50 条
  • [21] THE USE OF THE LONG STEM FEMORAL PROSTHESIS IN PRIMARY AND REVISION TOTAL HIP-REPLACEMENT OPERATIONS
    DOOLEY, BJ
    CLINICAL AND INVESTIGATIVE MEDICINE-MEDECINE CLINIQUE ET EXPERIMENTALE, 1985, 8 (03): : A146 - A146
  • [22] Mechanical effects of stem cement interface characteristics in total hip replacement
    Verdonschot, N
    Huiskes, R
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1996, (329) : 326 - 336
  • [23] MECHANISM OF FRACTURE OF THE FEMORAL PROSTHESIS IN TOTAL HIP-REPLACEMENT
    WROBLEWSKI, BM
    INTERNATIONAL ORTHOPAEDICS, 1979, 3 (02) : 137 - 139
  • [24] PRIMARY RESULTS OF TOTAL HIP-REPLACEMENT WITH BRUNSWIK PROSTHESIS
    VISURI, T
    SALENIUS, P
    LAURENT, LE
    SCANDINAVIAN JOURNAL OF RHEUMATOLOGY, 1975, 4 : 2204 - 2204
  • [25] TOTAL HIP REPLACEMENT USING MCBRIDE CUP AND MOORE PROSTHESIS
    LUNCEFORD, EM
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1970, (72) : 201 - +
  • [26] TOTAL HIP PROSTHETIC REPLACEMENT WITH LONG-SHAFTED PROSTHESIS
    THON, K
    MAROSKE, D
    MONNICH, D
    LANGENBECKS ARCHIV FUR CHIRURGIE, 1981, 355 : 558 - 558
  • [27] Position of the prosthesis and the incidence of dislocation following total hip replacement
    He Rong-xin
    Yan Shi-gui
    Wu Li-dong
    Wang Xiang-hua
    Dai Xue-song
    CHINESE MEDICAL JOURNAL, 2007, 120 (13) : 1140 - 1144
  • [28] FATIGUE FRACTURES OF FEMORAL PROSTHESIS IN TOTAL HIP-REPLACEMENT
    CHARNLEY, J
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1976, 58 (03): : 390 - 390
  • [29] USE OF CERAMIC TOTAL PROSTHESIS FOR REPLACEMENT OF LOOSE HIP ENDOPROSTHESIS
    ROSSAK, K
    BRINKMANN, KE
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1979, 117 (04): : 485 - 488
  • [30] PROBLEMS AND THEIR POSSIBLE SOLUTION IN REPLACEMENT OF TOTAL HIP-PROSTHESIS
    HERMICHEN, HG
    HOLZ, U
    LANGENBECKS ARCHIV FUR CHIRURGIE, 1981, 355 : 558 - 558