Flexible Palladium-silver Nanowire Electrode for Non-enzymatic Glucose Detection

被引:0
|
作者
Meng, Wei-Chen [1 ]
Wang, Qing-Xiang [1 ]
Li, Yan-Zhao [2 ]
Feng, Ling-Zhu [1 ]
Lang, Ming-Fei [3 ]
Chen, Hong-Shen [2 ]
Sun, Jing [1 ]
机构
[1] Dalian Univ, Coll Environm & Chem Engn, Dalian 116622, Peoples R China
[2] Dalian Univ, Affiliated Zhongshan Hosp, Dalian 116622, Peoples R China
[3] Dalian Univ, Coll Med, Dalian 116622, Peoples R China
基金
中国国家自然科学基金;
关键词
Flexible electrode; Enzyme-free biosensors; Silver nanowire; Glucose; ELECTROCHEMICAL DETECTION; NANOCOMPOSITE; SENSOR;
D O I
10.19756/j.issn.0253-3820.191672
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Diabetes has become a prominent issue that threatens human's health. Minimally invasive blood glucose testing may cause inconvenience and pain to patients. Wearable non-invasive blood glucose testing is becoming a hot topic in the scientific and medical field. In this study, novel palladium. silver nanowires (Pd. AgNWs) flexible electrodes were prepared by electrochemical deposition of Pd nanoparticles on the electrode with polydimethylsiloxane (PDMS) as the substrate and AgNWs as the conductive layer. The nanoparticles were uniformly deposited on AgNWs and different Pd. AgNWs electrodes were made by changing Pd deposition cycles. By using them as the working electrodes, glucose was detected by cyclic voltammetry. It was found that the Pd-AgNWs electrode deposited with 25 cycles of palladium had the best results in the detection of glucose. The experimental conditions of glucose detection were optimized. The linear ranges of glucose were 0.02-0.5 mmol/L and 1-4 mmol/L when detecting glucose by current.time method. The detection limit was 1 mu mol/L and the response sensitivity was 33.18 mu A/(cm(2)(mmol/L)) (S/N = 3). This electrode exhibited good reproducibility, stability, selectivity, as well as good response in detection of salivary glucose.
引用
收藏
页码:363 / 370
页数:8
相关论文
共 27 条
  • [11] In situ synthesis of palladium nanoparticle-graphene nanohybrids and their application in nonenzymatic glucose biosensors
    Lu, Li-Min
    Li, Hong-Bo
    Qu, Fengli
    Zhang, Xiao-Bing
    Shen, Guo-Li
    Yu, Ru-Qin
    [J]. BIOSENSORS & BIOELECTRONICS, 2011, 26 (08): : 3500 - 3504
  • [12] DECREASED SALIVARY GLUCOSE SECRETORY RATE - USEFULNESS FOR DETECTION OF DIABETIC-PATIENTS WITH AUTONOMIC NEUROPATHY
    MARCHETTI, P
    TOGNARELLI, M
    GIANNARELLI, R
    GROSSI, C
    PICARO, L
    DICARLO, A
    BENZI, L
    CICCARONE, A
    NAVALESI, R
    [J]. DIABETES RESEARCH AND CLINICAL PRACTICE, 1989, 7 (03) : 181 - 186
  • [13] PAROTID-GLAND BASEMENT-MEMBRANE VARIATION IN DIABETES-MELLITUS
    MURRAH, VA
    CROSSON, JT
    SAUK, JJ
    [J]. JOURNAL OF ORAL PATHOLOGY & MEDICINE, 1985, 14 (03) : 236 - 246
  • [14] Nonenzymatic electrochemical glucose sensor based on novel Pt-Pd nanoflakes
    Niu, Xiangheng
    Lan, Minbo
    Chen, Chen
    Zhao, Hongli
    [J]. TALANTA, 2012, 99 : 1062 - 1067
  • [15] Highly Stretchable and Sensitive Unidirectional Strain Sensor via Laser Carbonization
    Rahimi, Rahim
    Ochoa, Manuel
    Yu, Wuyang
    Ziaie, Babak
    [J]. ACS APPLIED MATERIALS & INTERFACES, 2015, 7 (08) : 4463 - 4470
  • [16] Nonenzymatic glucose sensor based on over-oxidized polypyrrole modified Pd/Si microchannel plate electrode
    Shi, Jing
    Ci, Pengliang
    Wang, Fei
    Peng, Hui
    Yang, Pingxiong
    Wang, Lianwei
    Ge, Shuli
    Wang, Qingjiang
    Chu, Paul K.
    [J]. BIOSENSORS & BIOELECTRONICS, 2011, 26 (05): : 2579 - 2584
  • [17] Home monitoring of sleep with a temporary-tattoo EEG, EOG and EMG electrode array:a feasibility study
    Shustak, Shiran
    Inzelberg, Lilah
    Steinberg, Stanislav
    Rand, David
    Pur, Moshe David
    Hillel, Inbar
    Katzav, Shlomit
    Fahoum, Firas
    De Vos, Maarten
    Mirelman, Anat
    Hanein, Yael
    [J]. JOURNAL OF NEURAL ENGINEERING, 2019, 16 (02)
  • [18] Ecoflex-Passivated Graphene-Yarn Composite for a Highly Conductive and Stretchable Strain Sensor
    Son, Wonkyeong
    Kim, Kyu-Beom
    Lee, Sangmin
    Hyeon, Gibaek
    Hwang, Kyung-Gyun
    Park, Wanjun
    [J]. JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2019, 19 (10) : 6690 - 6695
  • [19] [孙慧斌 Sun Huibin], 2002, [实用口腔医学杂志, Journal of Practical Stomatology], V18, P344
  • [20] Implantable and Flexible Electronics for in Vivo Brain Activity Recordings
    Wang Jin-Fen
    Tian Hui-Hui
    Fang Ying
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2019, 47 (10) : 1549 - 1558