Comparison of in vivo polyethylene wear particles between mobile- and fixed-bearing TKA in the same patients

被引:8
|
作者
Minoda, Yukihide [1 ]
Hata, Kanako [1 ]
Ikebuchi, Mitsuhiko [1 ]
Mizokawa, Shigekazu [1 ]
Ohta, Yoichi [1 ]
Nakamura, Hiroaki [1 ]
机构
[1] Osaka City Univ, Grad Sch Med, Dept Orthopaed Surg, Abeno Ku, 1-4-3 Asahi Machi, Osaka 5458585, Japan
关键词
Total knee arthroplasty; Polyethylene wear particle; Mobile-bearing prosthesis; Fixed-bearing prosthesis; TOTAL KNEE ARTHROPLASTY; CROSS-LINKED POLYETHYLENE; SYNOVIAL-FLUID; TOTAL JOINT; REPLACEMENT; PROSTHESES; SYSTEM;
D O I
10.1007/s00167-016-4027-z
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Polyethylene wear particle generation is one of the most important factors that affects the mid- to long-term results of total knee arthroplasties (TKA). Mobile-bearing total knee prostheses were developed to reduce polyethylene wear generation. However, whether mobile-bearing prostheses actually generate fewer polyethylene wear particles than fixed-bearing prostheses remains controversial. The aim of this study was to compare, within individual patients, the in vivo polyethylene wear particles created by a newly introduced mobile-bearing prosthesis in one knee and a conventional fixed-bearing prosthesis in other knee. Eighteen patients receiving bilateral TKAs to treat osteoarthritis were included. The synovial fluid was obtained from 36 knees at an average of 3.5 years after the operation. The in vivo polyethylene wear particles were isolated from the synovial fluid using a previously validated method and examined using a scanning electron microscope and an image analyser. The size and shape of the polyethylene wear particles from the mobile-bearing prostheses were similar to those from the conventional fixed-bearing prostheses. Although the number of wear particles from the mobile-bearing prosthesis (1.63 x 10(7) counts/knee) appeared smaller than that from the fixed-bearing prosthesis (2.16 x 10(7) counts/knee), the difference was not statistically significant. The current in vivo study shows that no statistically significant differences were found between the polyethylene wear particles generated by a newly introduced mobile-bearing PS prosthesis and a conventional fixed-bearing PS prosthesis during the early clinical stage after implantation. Therapeutic study, Level III.
引用
收藏
页码:2887 / 2893
页数:7
相关论文
共 50 条
  • [41] Comparison of ultra-congruent mobile- and fixed-bearing navigation-assisted total knee arthroplasty with minimum 5-year follow-up
    Seong Hwan Kim
    Jung-Won Lim
    Young-Bong Ko
    Min-Gu Song
    Han-Jun Lee
    Knee Surgery, Sports Traumatology, Arthroscopy, 2016, 24 : 3466 - 3473
  • [42] Letter to the Editor: Early Outcome of TKA with a Medial Pivot Fixed-bearing Prosthesis Is Worse Than With a PFC Mobile-bearing Prosthesis
    Pritchett, James W.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (01) : 303 - 303
  • [43] In Vivo Determination of Cam-Post Engagement in Fixed and Mobile-bearing TKA
    Zingde, Sumesh M.
    Leszko, Filip
    Sharma, Adrija
    Mahfouz, Mohamed R.
    Komistek, Richard D.
    Dennis, Douglas A.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2014, 472 (01) : 254 - 262
  • [44] Letter to the Editor: Early Outcome of TKA with a Medial Pivot Fixed-bearing Prosthesis is Worse than with a PFC Mobile-bearing Prosthesis
    Scott, Gareth
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (03) : 855 - 856
  • [45] Comparison of survival rate and risk of revision for mobile-bearing and fixed-bearing total knee replacements
    Lacko, Marek
    Schreierova, Daniela
    EKLEM HASTALIKLARI VE CERRAHISI-JOINT DISEASES AND RELATED SURGERY, 2019, 30 (02): : 70 - 78
  • [46] Fixed-Bearing versus Mobile-Bearing Unicondylar Knee Arthroplasty: Comparison of Patients with Similar Component and Mechanical Axis Alignment
    Saylik, Murat
    Ergun, Selim
    Gunes, Taner
    DUZCE MEDICAL JOURNAL, 2022, 24 (03) : 293 - 298
  • [47] Comparison of fixed-bearing and mobile-bearing total knee arthroplasty after high tibial osteotomy
    Philippe Hernigou
    Maxime Huys
    Jacques Pariat
    François Roubineau
    Charles Henri Flouzat Lachaniette
    Arnaud Dubory
    International Orthopaedics, 2018, 42 : 317 - 322
  • [48] Comparison of fixed-bearing and mobile-bearing total knee arthroplasty after high tibial osteotomy
    Hernigou, Philippe
    Huys, Maxime
    Pariat, Jacques
    Roubineau, Francois
    Lachaniette, Charles Henri Flouzat
    Dubory, Arnaud
    INTERNATIONAL ORTHOPAEDICS, 2018, 42 (02) : 317 - 322
  • [49] Long-Term Comparison of Mobile-Bearing vs Fixed-Bearing Total Knee Arthroplasty
    Woolson, Steven T.
    Epstein, Noah J.
    Huddleston, James I.
    JOURNAL OF ARTHROPLASTY, 2011, 26 (08): : 1219 - 1223
  • [50] Wear-pattern analysis in retrieved tibial inserts of mobile-bearing and fixed-bearing total knee prostheses
    Lu, Y. -C.
    Huang, C. -H.
    Chang, T. -K.
    Ho, F. -Y.
    Cheng, C. -K.
    Huang, C. -H.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2010, 92B (04): : 500 - 507