A numerical investigation of the compressible flow in the ejector of a vapour ejector refrigeration system

被引:4
|
作者
Megalingam, A. [1 ]
Babu, V. [1 ]
机构
[1] Indian Inst Technol Madras, Dept Mech Engn, Chennai 600036, Tamil Nadu, India
来源
关键词
numerical simulation; ejector; real gas effects; solar refrigeration; PERFORMANCE; PARAMETERS; DESIGN;
D O I
10.1504/PCFD.2020.104704
中图分类号
O414.1 [热力学];
学科分类号
摘要
Numerical simulations of the flow in a vapour ejector have been carried out. Real gas effects are accounted for in the calculations. Ejection as well as flow-through studies have been performed. Effects of the generator and evaporator temperatures and position of the primary nozzle have been investigated. Predicted values of the suction pressure and COP have been compared with experimental values reported in the literature. In addition, secondary flow area has also been evaluated and correlated with the COP. By tracking the sonic line and the edge of the primary stream and flow separation, insights on the gas dynamic and fluid dynamic aspects of the flow field and how they influence the entrainment of the secondary stream and consequently the COP are brought out. The study reveals that, in addition to the choking of the secondary stream, the expansion of the primary stream and the area available for the secondary stream also plays a key role in affecting the performance of the vapour ejector.
引用
收藏
页码:29 / 39
页数:11
相关论文
共 50 条
  • [31] Performance Analysis on a Power and Ejector-Refrigeration System and the Involved Ejector
    Zhang, Xiaolin
    Deng, Shuai
    Zhao, Li
    Su, Wen
    Xu, Weicong
    FRONTIERS IN ENERGY RESEARCH, 2019, 7
  • [32] Experimental Investigation on HFC134a Ejector Refrigeration System
    Zheng Hui-fan
    Fan Xiao-wei
    Li An-gui
    ICIEA: 2009 4TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOLS 1-6, 2009, : 2159 - +
  • [33] Experimental Investigation on Liquid-ring Ejector Refrigeration System
    Huang, Bi-Han
    Tang, Jian-Bo
    Zhou, Yuan
    Wang, Jun-Jie
    Ji, Wei
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2018, 39 (08): : 1643 - 1648
  • [34] Experimental Investigation of the Ejector Refrigeration Cycle for Cascade System Application
    Xinyue Hao
    Neng Gao
    Guangming Chen
    Oleksii Volovyk
    Xuehui Wang
    Yongmei Xuan
    Journal of Thermal Science, 2022, 31 : 1476 - 1486
  • [35] The Influence of Ejector's Structure Parameters on the Performance of Ejector Refrigeration System
    Hu, Wenju
    Wang, Meng-yuan
    Nie, Jin-zhe
    Gao, Yan
    Zhang, Qun-li
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 2683 - 2690
  • [36] Investigation on vapor ejector refrigeration system driven by capillary force
    Shi, Ming-Heng
    Cai, Hui
    Wang, Xing-Chun
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2004, 25 (05): : 745 - 748
  • [37] An experimental investigation of ejector performance characteristics in a jet refrigeration system
    Huang, MC
    Chen, SL
    JOURNAL OF THE CHINESE INSTITUTE OF CHEMICAL ENGINEERS, 1996, 27 (02): : 91 - 100
  • [38] An experimental investigation on exergy analysis of an ejector expansion refrigeration system
    Sag, Nagihan Bilir
    Ersoy, Halil Kursad
    Hepbasli, Arif
    INTERNATIONAL JOURNAL OF EXERGY, 2017, 24 (2-4) : 201 - 215
  • [39] An experimental investigation of a R-134a ejector refrigeration system
    Garcia del Valle, J.
    Saiz Jabardo, J. M.
    Castro Ruiz, F.
    San Jose Alonso, J. F.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2014, 46 : 105 - 113
  • [40] Experimental investigation on two-phase driven ejector performance in a novel ejector enhanced refrigeration system
    Wang, Xiao
    Yu, Jianlin
    ENERGY CONVERSION AND MANAGEMENT, 2016, 111 : 391 - 400