Relation Between the Characteristic X-Ray Intensity and Incident Electron Energy Using the Monte Carlo Method and Measurements

被引:2
|
作者
Gu, Runqiu [1 ]
Cheng, Jianfeng [1 ]
Lai, Wanchang [1 ]
Liao, Xianli [1 ]
Wang, Guangxi [1 ]
Zhai, Juan [1 ]
Zeng, Chenhao [1 ]
Wu, Jinfei [1 ]
Sun, Xiaochuan [1 ]
机构
[1] Chengdu Univ Technol, Coll Nucl Technol & Automat Engn, Chengdu 610059, Peoples R China
关键词
X-ray tube; Monte Carlo; Si-PIN; characteristic X-ray; spectrum; TUBE SPECTRA; FLUORESCENCE; ALGORITHM; EMISSION; YIELDS; LINES; MODEL;
D O I
10.1080/00295450.2021.1957661
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The characteristic X-ray of a target is of considerable significance in industrial applications and medical diagnosis and treatment, and its intensity is closely related to the incident electron energy. At a high energy, it is not easy to determine the relation between characteristic X-rays and the incident electron energy through measurements, but the Monte Carlo method has a wide energy calculation range. In this study, the X-ray energy spectra of six target materials (Cu, Mo, Rh, Ag, W, and Pt) were simulated at various incident electron energies (<3 MeV) using the Monte Carlo code MCNP5 and the relation curve between the characteristic X-ray intensity of each of the target materials, and the incident electron energy was obtained through a simulation. A Si-PIN detector was used to measure the low-energy output energy spectra of two X-ray tubes (Ag and W targets). The relation curve between the X-ray tube excitation voltage and the characteristic X-ray intensity was obtained by fitting the measured data to a linear function. The simulation fitting curve and measurement fitting curve agreed well in the low-energy range. Comparisons of the calculated and measured values revealed that most of the deviations for the Ag target were less than 5%, and those for the W target were less than 6%.
引用
收藏
页码:912 / 921
页数:10
相关论文
共 50 条
  • [21] X-RAY COLLIMATOR DESIGN USING MONTE CARLO SIMULATIONS
    Han, Eun Young
    Clarkson, Richard
    Sharma, Sunil
    Corry, Peter M.
    Moros, Eduardo G.
    Ratanatharathorn, Vaneerat
    BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2013, 25 (06):
  • [22] Diagnostic x-ray dosimetry using Monte Carlo simulation
    Ioppolo, JL
    Price, RI
    Tuchyna, T
    Buckley, CE
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (10): : 1707 - 1720
  • [23] Measurements of inner-shell characteristic X-ray yields of thick W, Mo and Zr targets by low-energy electron impact and comparison with Monte Carlo simulations
    Li, X. L.
    Zhao, J. L.
    Tian, L. X.
    An, Z.
    Zhu, J. J.
    Liu, M. T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2014, 333 : 106 - 112
  • [24] Monte Carlo polarimetric simulations of a hard X-ray energy telescope
    da Silva, RMC
    Caroli, E
    Stephen, JB
    Siffert, P
    X-RAY AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY XII, 2002, 4497 : 70 - 78
  • [25] Monte Carlo simulations of dual energy X-ray inspection systems
    Department of Engineering Physics, Tsinghua University, Beijing 100084, China
    Qinghua Daxue Xuebao, 2006, 6 (813-816):
  • [26] The relation between X-ray intensity and ion energy of laser triggered ion acceleration
    Takano, K.
    Nayuki, T.
    Oishi, Y.
    Fujii, T.
    Takizawa, Y.
    Nemoto, K.
    Soda, K.
    Takashima, R.
    Hasegawa, S.
    Horioka, K.
    Hotta, E.
    JOURNAL DE PHYSIQUE IV, 2006, 133 : 1135 - 1138
  • [27] A Simulation Method for X-ray Pulsar Signal Based on Monte Carlo
    Jin, Jing
    Liu, Yixiao
    Li, Xiaoyu
    Shen, Yi
    Huang, Liangwei
    2016 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, 2016, : 1937 - 1942
  • [28] A MONTE CARLO CALCULATION OF SPATIAL DISTRIBUTION OF CHARACTERISTIC X-RAY PRODUCTION IN A SOLID TARGET
    GREEN, M
    PROCEEDINGS OF THE PHYSICAL SOCIETY OF LONDON, 1963, 82 (526): : 204 - +
  • [29] Characterization of target material for x-ray generator by Monte Carlo method
    Stankovic, S. J.
    llic, R. D.
    Ciraj-Bjelac, O.
    Kovacevic, M.
    Davidovic, D.
    RESEARCH TRENDS IN CONTEMPORARY MATERIALS SCIENCE, 2007, 555 : 137 - +
  • [30] CALCULATION OF X-RAY-EMISSION INTENSITY IN MULTILAYER FILMS USING MONTE-CARLO METHOD
    HE, YC
    CHEN, JG
    WANG, XL
    SCIENCE IN CHINA SERIES A-MATHEMATICS PHYSICS ASTRONOMY, 1989, 32 (12): : 1491 - 1498