Glucose levels between the anterior chamber of the eye and blood are correlated based on blood glucose dynamics

被引:4
|
作者
Kurihara, Toshihide [1 ,2 ]
Lee, Deokho [1 ,2 ]
Shinojima, Ari [1 ,2 ]
Kinoshita, Taku [3 ,4 ]
Nishizaki, Saori [3 ]
Arita, Yoko [1 ]
Hidaka, Yuki [2 ]
Nishi, Yasuyo [2 ]
Shirakawa, Yoshinori [3 ]
Kimura, Sho [3 ]
Tsuneyoshi, Yukari [2 ]
Torii, Hidemasa [2 ]
Tsubota, Kazuo [2 ,5 ]
Negishi, Kazuno [2 ]
机构
[1] Keio Univ, Lab Photobiol, Sch Med, Tokyo, Japan
[2] Keio Univ, Dept Ophthalmol, Sch Med, Tokyo, Japan
[3] Fuji Xerox Co Ltd, Tokyo, Japan
[4] SEED Co Ltd, Tokyo, Japan
[5] Tsubota Lab Inc, Tokyo, Japan
来源
PLOS ONE | 2021年 / 16卷 / 09期
关键词
AQUEOUS-HUMOR;
D O I
10.1371/journal.pone.0256986
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Glycemic control is essential to manage metabolic diseases such as diabetes. Frequent measurements of systemic glucose levels with prompt managements can prevent organ damages. The eye is a glucose highly demanding organ in our body, and the anterior chamber (AC) in the eye has been suggested for a noninvasive blood glucose monitoring site. However, calculating blood glucose levels from measuring glucose levels in AC has been difficult and unclear. In this study, we aimed to examine glucose levels from AC and find a correlation with blood glucose levels. A total of 30 patients with cataracts (men and women, study 1; 7 and 3, study 2; 9 and 11) who visited Keio University Hospital from 2015 to 2018 and agreed to participate in this study were recruited. Glucose levels from AC and the blood were examined by a UV-hexokinase or H2O2-electrode method before/during the cataract surgery. These values were analyzed with regression analyses depending on the groups (blood glucose-ascending and descending groups). In the blood glucose-descending group, glucose levels from AC were strongly correlated with blood glucose levels (a high R-2 value, 0.8636). However, the relatively moderate correlation was seen in the blood glucose-ascending group (a low R-2 value, 0.5228). Taken together, we showed different correlation ratios on glucose levels between AC and the blood, based on blood glucose dynamics. Stacking data regarding this issue would enable establishing noninvasive blood glucose monitoring from measuring glucose levels in AC more correctly, which will be helpful for proper and prompt managements for glucose-mediated complications.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] BLOOD-GLUCOSE LEVELS AND PROTEINURIA
    SILVA, FG
    WEBER, CJ
    PIRANI, CL
    HARDY, MA
    REEMTSMA, K
    NEW ENGLAND JOURNAL OF MEDICINE, 1979, 301 (03): : 160 - 160
  • [42] MEASURING BLOOD-GLUCOSE LEVELS
    ISLES, TE
    LANCET, 1967, 2 (7524): : 1043 - &
  • [43] MEASUREMENT OF BLOOD-GLUCOSE LEVELS
    JACOBS, P
    DAGNALL, P
    FACKEREL.R
    WESTON, P
    LANCET, 1968, 1 (7547): : 860 - +
  • [44] Blood glucose levels and problem behavior
    Valdovinos, MG
    Weyand, D
    RESEARCH IN DEVELOPMENTAL DISABILITIES, 2006, 27 (02) : 227 - 231
  • [45] Are blood glucose levels affected by menopause?
    Freeman, Ruth
    MENOPAUSE-THE JOURNAL OF THE NORTH AMERICAN MENOPAUSE SOCIETY, 2007, 14 (03): : 350 - 351
  • [46] MEASUREMENT OF BLOOD-GLUCOSE LEVELS
    SACRE, M
    WALKER, G
    LANCET, 1968, 1 (7550): : 1034 - +
  • [47] MEASUREMENT OF BLOOD-GLUCOSE LEVELS
    COX, MH
    LANCET, 1968, 1 (7544): : 692 - &
  • [48] MEASUREMENT OF BLOOD-GLUCOSE LEVELS
    不详
    LANCET, 1968, 1 (7539): : 405 - +
  • [49] NUTRITIONAL MANAGEMENT OF BLOOD GLUCOSE LEVELS
    Russell, W.
    Baka, A.
    Bjorck, I.
    Delzenne, N.
    Gao, D.
    Griffiths, H.
    Hadjilucas, E.
    Juvonen, K.
    Lahtinen, S.
    Lansink, M.
    van Loon, L.
    Mykkanen, H.
    Ostman, E.
    Riccardi, G.
    Vinoy, S.
    Weickert, M.
    ANNALS OF NUTRITION AND METABOLISM, 2013, 63 : 1339 - 1340
  • [50] BLOOD GLUCOSE LEVELS IN NORMAL DOG
    KIDDER, DE
    ROUSE, BT
    VETERINARY RECORD, 1966, 79 (03) : 87 - &