Interatrial Septal Aneurysm and Patent Foramen Ovale Diagnosis and Dynamic Evaluation With Electrocardiogram-gated Multidetector-Row Computed Tomography Imaging

被引:1
|
作者
Ghersin, Eduard [1 ]
Ramos, Geraldo A. [2 ]
Soto, Victor [2 ]
Lopera, Gustavo [2 ]
Fishman, Joel E. [1 ]
Lessick, Jonathan [3 ]
机构
[1] Univ Miami, Dept Radiol, Leonard M Miller Sch Med, Miami, FL USA
[2] Univ Miami, Dept Cardiol, Leonard M Miller Sch Med, Miami, FL USA
[3] Technion Israel Inst Technol, Dept Cardiol, B Rappaport Sch Med, Haifa, Israel
关键词
electrocardiogram-gated multidetector-row computed tomography; echocardiography; patent foramen ovale; interatrial septal aneurysm; atrial fibrillation;
D O I
10.1097/RTI.0b013e3181fabc12
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We describe an elderly woman with paroxysmal atrial fibrillation who was evaluated by electrocardiogram-gated multidetector-row computed tomography (MDCT) prior to left atrial radiofrequency ablation therapy to rule out coronary artery disease and to obtain a 3-dimensional anatomical map of the left atrium and pulmonary veins. MDCT documented the dynamic bidirectional motion of an interatrial septal aneurysm associated with a patent foramen ovale. MDCT findings correlated well with transesophageal and intracardiac echocardiograms.
引用
收藏
页码:W143 / W145
页数:3
相关论文
共 25 条
  • [11] Multiple Giant Coronary Artery Aneurysms Due to Kawasaki Disease: Electrocardiogram-Gated 64-Slice Multidetector Row Computed Tomography Findings
    Kwon, Se Hwan
    Oh, Joo Hyeong
    Han, Mi-Young
    PEDIATRIC CARDIOLOGY, 2009, 30 (01) : 89 - 90
  • [12] Multiple Giant Coronary Artery Aneurysms Due to Kawasaki Disease: Electrocardiogram-Gated 64-Slice Multidetector Row Computed Tomography Findings
    Se Hwan Kwon
    Joo Hyeong Oh
    Mi-Young Han
    Pediatric Cardiology, 2009, 30 : 89 - 90
  • [13] Evaluation of Prosthetic Valve Obstruction on Electrocardiographically Gated Multidetector-Row Computed Tomography - Identification of Subprosthetic Pannus in the Aortic Position
    Ueda, Tomohiro
    Teshima, Hideki
    Fukunaga, Shuji
    Aoyagi, Shigeaki
    Tanaka, Hiroyuki
    CIRCULATION JOURNAL, 2013, 77 (02) : 418 - 423
  • [14] A prospective comparison between multidetector-row computed tomography and magnetic resonance imaging in the preoperative evaluation of rectal carcinoma
    Matsuoka, H
    Nakamura, A
    Masaki, T
    Sugiyama, M
    Takahara, T
    Hachiya, J
    Atomi, Y
    AMERICAN JOURNAL OF SURGERY, 2003, 185 (06): : 556 - 559
  • [15] Evaluation of aortic non-involvement of esophageal squamous cell cancer by electrocardiogram-gated 320-row area detector computed tomography
    Shuto, K.
    Yamazaki, M.
    Kosugi, T.
    Koda, K.
    Matsubara, H.
    EUROPEAN JOURNAL OF CANCER, 2013, 49 : S609 - S609
  • [16] Multidetector-Row Computed Tomography Angiography in Abdominal Aortic Aneurysm Treated With Endovascular Repair: Evaluation of Optimal Timing of Delayed Phase Imaging for the Detection of Low-Flow Endoleaks
    Iezzi, Roberto
    Cotroneo, Antonio Raffaele
    Filippone, Antonella
    Santoro, Marco
    Basilico, Raffaella
    Storto, Maria Luigia
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2008, 32 (04) : 609 - 615
  • [17] A Comprehensive Electrocardiogram-Gated 64-Slice Multidetector Computed Tomography Imaging Protocol to Visualize the Coronary Arteries, Thoracic Aorta, and Pulmonary Vasculature in a Single Breath Hold
    Shapiro, Michael D.
    Dodd, Jonathan D.
    Kalva, Sanjeeva
    Wittram, Conrad
    Hsu, Joe
    Nasir, Khurram
    Liu, Bob
    Nagurney, John T.
    Kalra, Mannudeep K.
    Nichols, John H.
    Cury, Ricardo C.
    Abbara, Suhny
    Tawakol, Ahmed
    Brady, Thomas J.
    Hoffman, Udo
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2009, 33 (02) : 225 - 232
  • [18] Quantitative assessment of arterial stiffness by multiphase analysis in retrospectively electrocardiogram-gated multidetector row computed tomography - Comparison between patients under chronic hemodialysis and age-matched controls
    Nagatani, Yukihiro
    Takahashi, Masashi
    Nitta, Norihisa
    Takazakura, Ryutaro
    Asai, Toru
    Ushio, Noritoshi
    Otani, Hideji
    Murakami, Yoko
    Murata, Kiyoshi
    INVESTIGATIVE RADIOLOGY, 2008, 43 (03) : 195 - 201
  • [19] Evaluation of Electrocardiogram-Gated Computed Tomography Angiography to Quantify Changes in Geometry and Dynamic Behavior during the Cardiac Cycle of the Nellix Endovascular Sealing System
    van den Ham, Leo H.
    Lazarian, Talar
    Jebbink, Erik Groot
    Lardenoije, Jan-Willem
    Zeebregts, Clark J.
    Reijnen, Michel M. P. J.
    RADIOLOGY RESEARCH AND PRACTICE, 2023, 2023
  • [20] Imaging aid for thoracic surgery: multidetector-row computed tomography evaluation of the tracheobronchial structure and bronchial tube selection for one-lung anesthesia
    Okuda, Itsuko
    Yamase, Hiromi
    Ogawa, Shigeru
    Udagawa, Harushi
    Kohno, Tadasu
    GENERAL THORACIC AND CARDIOVASCULAR SURGERY, 2009, 57 (07) : 369 - 375