Electrocoagulation/electroflotation in an external-loop airlift reactor - Application to the decolorization of textile dye wastewater: A case study

被引:120
|
作者
Essadki, A. H. [1 ]
Bennajah, M. [1 ]
Gourich, B.
Vial, Ch. [2 ]
Azzi, M. [3 ]
Delmas, H. [4 ]
机构
[1] Ecole Super Technol Casablanca, Oasis Casablanca, Morocco
[2] LGCB UBP ENSCCF, Lab Gen Chim & Biochim, F-63174 Aubiere, France
[3] Fac Sci Ain Chock, Lab Electrochim & Chim Environ, Casablanca, Morocco
[4] ENSIACET INPT, Lab Gin Chim, F-31106 Toulouse, France
关键词
electrocoagulation; electroflotation; external-loop airlift reactor; COD removal; decolorization;
D O I
10.1016/j.cep.2007.03.013
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A 20 L extemal-loop airlift reactor was used as an electrochemical cell in order to carry out water depollution using batch electrocoagulation (EC) without mechanical agitation, pumping requirements or air injection. Mixing and complete flotation of the pollutants were achieved using only the overall liquid recirculation induced by H-2 microbubbles generated by water electrolysis. A red dye from the Moroccan textile industry was used in a case study to validate this innovative application of airlift reactors. Experimental results showed that the axial position of the Al electrodes and the residence time in the separator section were the key parameters to achieve good mixing conditions, to avoid bubbles/particles recirculation in the downcomer and to prevent floc break-up/erosion by hydrodynamic shear forces. Such optimum conditions corresponded to an optimum liquid overall recirculation velocity that was correlated to current, electrode position and dispersion height. Operation time required to achieve 80% COD and 80% color removal efficiencies was modeled as a function of current density. Similarly, specific energy and electrode consumptions were correlated to current, electrode gap and conductivity, which provided the necessary tools for scale-up and process optimization. Operation time and removal efficiencies were similar to those reported in conventional EC cells, but specific energy and electrode consumptions were even smaller without the need for mechanical agitation, pumping requirements and air injection, which could not be achieved in other kinds of conventional gas-liquid contacting devices. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:1211 / 1223
页数:13
相关论文
共 50 条
  • [21] Experimental and Numerical Study of Gas-Liquid Flow in a Sectionalized External-Loop Airlift Reactor
    Teli, Shivanand M.
    Mathpati, Channamallikarjun S.
    CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2021, 32 : 39 - 60
  • [22] Experimental and Numerical Study of Gas-Liquid Flow in a Sectionalized External-Loop Airlift Reactor
    Shivanand M.Teli
    Channamallikarjun S.Mathpati
    Chinese Journal of Chemical Engineering, 2021, 32 (04) : 39 - 60
  • [23] Experimental study on the local hydrodynamic behavior of a three-phase external-loop airlift reactor
    Jing, L
    Han, MH
    Wang, TF
    Zhang, TW
    Wang, JF
    Yong, J
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2004, 43 (18) : 5432 - 5437
  • [24] TURN-AROUND ENERGY-LOSSES IN AN EXTERNAL-LOOP AIRLIFT REACTOR
    AKITA, K
    NAKANISHI, O
    TSUCHIYA, K
    CHEMICAL ENGINEERING SCIENCE, 1994, 49 (15) : 2521 - 2533
  • [25] Effect of unaerated liquid height on hydrodynamic characteristics of an external-loop airlift reactor
    Choi, KH
    CHEMICAL ENGINEERING COMMUNICATIONS, 2002, 189 (01) : 23 - 39
  • [26] EFFECT OF LIQUID VISCOSITY ON HYDRODYNAMICS AND BUBBLE BEHAVIOUR OF AN EXTERNAL-LOOP AIRLIFT REACTOR
    Wu, Qian
    Wang, Xuekui
    Wang, Tiefeng
    Han, Mei
    Sha, Zuoliang
    Wang, Jinfu
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 2013, 91 (12): : 1957 - 1963
  • [27] Liquid circulation and mass transfer in an external-loop airlift reactor with partitioning plates
    Tsuge, H
    Otatsume, S
    Kobayashi, K
    Terasaka, K
    Hayasaki, M
    Kobayashi, H
    JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 2004, 37 (08) : 941 - 946
  • [28] STUDY OF THE LIQUID CIRCULATION VELOCITY IN EXTERNAL-LOOP AIRLIFT BIOREACTORS
    GAVRILESCU, M
    TUDOSE, RZ
    BIOPROCESS ENGINEERING, 1995, 14 (01): : 33 - 39
  • [29] LIQUID-PHASE PROPERTIES AND SPARGER DESIGN EFFECTS IN AN EXTERNAL-LOOP AIRLIFT REACTOR
    SNAPE, JB
    ZAHRADNIK, J
    FIALOVA, M
    THOMAS, NH
    CHEMICAL ENGINEERING SCIENCE, 1995, 50 (20) : 3175 - 3186
  • [30] Influence of the Sparger Type and Added Alcohol on the Gas Holdup of an External-Loop Airlift Reactor
    Kojic, Predrag S.
    Tokic, Milenko S.
    Sijacki, Ivana M.
    Lukic, Natasa Lj.
    Petrovic, Dragan Lj.
    Jovicevic, Dragica Z.
    Popovic, Svetlana S.
    CHEMICAL ENGINEERING & TECHNOLOGY, 2015, 38 (04) : 701 - 708