Electrocoagulation/electroflotation in an external-loop airlift reactor - Application to the decolorization of textile dye wastewater: A case study

被引:120
|
作者
Essadki, A. H. [1 ]
Bennajah, M. [1 ]
Gourich, B.
Vial, Ch. [2 ]
Azzi, M. [3 ]
Delmas, H. [4 ]
机构
[1] Ecole Super Technol Casablanca, Oasis Casablanca, Morocco
[2] LGCB UBP ENSCCF, Lab Gen Chim & Biochim, F-63174 Aubiere, France
[3] Fac Sci Ain Chock, Lab Electrochim & Chim Environ, Casablanca, Morocco
[4] ENSIACET INPT, Lab Gin Chim, F-31106 Toulouse, France
关键词
electrocoagulation; electroflotation; external-loop airlift reactor; COD removal; decolorization;
D O I
10.1016/j.cep.2007.03.013
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A 20 L extemal-loop airlift reactor was used as an electrochemical cell in order to carry out water depollution using batch electrocoagulation (EC) without mechanical agitation, pumping requirements or air injection. Mixing and complete flotation of the pollutants were achieved using only the overall liquid recirculation induced by H-2 microbubbles generated by water electrolysis. A red dye from the Moroccan textile industry was used in a case study to validate this innovative application of airlift reactors. Experimental results showed that the axial position of the Al electrodes and the residence time in the separator section were the key parameters to achieve good mixing conditions, to avoid bubbles/particles recirculation in the downcomer and to prevent floc break-up/erosion by hydrodynamic shear forces. Such optimum conditions corresponded to an optimum liquid overall recirculation velocity that was correlated to current, electrode position and dispersion height. Operation time required to achieve 80% COD and 80% color removal efficiencies was modeled as a function of current density. Similarly, specific energy and electrode consumptions were correlated to current, electrode gap and conductivity, which provided the necessary tools for scale-up and process optimization. Operation time and removal efficiencies were similar to those reported in conventional EC cells, but specific energy and electrode consumptions were even smaller without the need for mechanical agitation, pumping requirements and air injection, which could not be achieved in other kinds of conventional gas-liquid contacting devices. (c) 2007 Elsevier B.V. All rights reserved.
引用
下载
收藏
页码:1211 / 1223
页数:13
相关论文
共 50 条
  • [1] Electrocoagulation/electroflotation of reactive, disperse and mixture dyes in an external-loop airlift reactor
    Balla, Wafaa
    Essadki, A. H.
    Gourich, B.
    Dassaa, A.
    Chenik, H.
    Azzi, M.
    JOURNAL OF HAZARDOUS MATERIALS, 2010, 184 (1-3) : 710 - 716
  • [2] Kinetic study of defluoridation of drinking water by electrocoagulation/electroflotation in a stirred tank reactor and in an external-loop airlift reactor
    Essadki, A. H.
    Gourich, B.
    Azzi, M.
    Vial, Ch.
    Delmas, H.
    CHEMICAL ENGINEERING JOURNAL, 2010, 164 (01) : 106 - 114
  • [3] Defluoridation of drinking water by electrocoagulation/electroflotation in a stirred tank reactor with a comparative performance to an external-loop airlift reactor
    Essadki, A. H.
    Gourich, B.
    Vial, Ch.
    Delmas, H.
    Bennajah, M.
    JOURNAL OF HAZARDOUS MATERIALS, 2009, 168 (2-3) : 1325 - 1333
  • [4] Photovoltaic electrocoagulation treatment of olive mill wastewater using an external-loop airlift reactor
    Elkacmi, Reda
    Boudouch, Otmane
    Hasib, Aziz
    Bouzaid, Mustapha
    Bennajah, Mounir
    SUSTAINABLE CHEMISTRY AND PHARMACY, 2020, 17
  • [5] Electrocoagulation/Electroflotation of real textile effluent: Improvement of the process in non-conventional pilot external loop airlift reactor
    Elhafdi, Mohammed
    Benchikhi, Mohamed
    Dassa, Aabderrahim
    Chenik, Hachemi
    Essadki, Aabdelhafid
    Azzi, Mohamed
    MOROCCAN JOURNAL OF CHEMISTRY, 2020, 8 (03): : 718 - 731
  • [6] Defluoridation of Morocco drinking water by electrocoagulation/electroflottation in an electrochemical external-loop airlift reactor
    Bennajah, M.
    Gourich, B.
    Essadki, A. H.
    Vial, Ch.
    Delmas, H.
    CHEMICAL ENGINEERING JOURNAL, 2009, 148 (01) : 122 - 131
  • [7] Ozone assisted electrocoagulation in a rectangular internal-loop airlift reactor: Application to decolorization of acid dye
    Behin, Jamshid
    Farhadian, Negin
    Ahmadi, Mojtaba
    Parvizi, Mehdi
    JOURNAL OF WATER PROCESS ENGINEERING, 2015, 8 : 171 - 178
  • [8] Flow Characteristics in an External-Loop Airlift Slurry Reactor
    Tang Xiaojin
    CHINA PETROLEUM PROCESSING & PETROCHEMICAL TECHNOLOGY, 2012, 14 (01) : 46 - 49
  • [9] Flow Characteristics in an External-Loop Airlift Slurry Reactor
    Tang Xiaojin(Research Institute of Petroleum Processing
    China Petroleum Processing & Petrochemical Technology, 2012, 14 (01) : 46 - 49
  • [10] HYDRODYNAMICS OF AN EXTERNAL-LOOP AIRLIFT REACTOR WITH INSERTED MEMBRANE
    Kojic, P. S.
    Popovic, S. S.
    Tokic, M. S.
    Sijacki, I. M.
    Lukic, N. Lj.
    Jovicevic, D. Z.
    Petrovic, D. Lj.
    BRAZILIAN JOURNAL OF CHEMICAL ENGINEERING, 2017, 34 (02) : 493 - 505