Evaluation of a New Automated Routine Measurement for Serum Adjusted Ionized Calcium (at pH 7.4) in Patients Suspected of Calcium Metabolic Disease

被引:3
|
作者
Kur, Dar K. [1 ]
Hillig, Thore [1 ]
Hansen, Steen, I [1 ]
Goharian, Tina [1 ]
Witte, Majbritt L. [1 ]
Thode, Jorgen [1 ]
机构
[1] Univ Copenhagen, North Zealand Hosp Hilleroed, Dept Clin Biochem, Copenhagen, Denmark
来源
关键词
POINT-OF-CARE; BLOOD-GAS; ALBUMIN; ELECTROLYTE; PLASMA; INTERVALS; ANALYZER; PROTEIN; STORAGE;
D O I
10.1093/jalm/jfaa006
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Total calcium is a less accurate test in predicting ionized calcium (Ca2+) in patients suspected of calcium metabolic disease. Nevertheless, total calcium continues to be used as routine measurement instead of adjusted Ca2+ (at pH 7.4). In the current study we evaluate a new multichannel instrument, the ISE Module E1200 for adjusted Ca2+ (at pH 7.4), containing three different ion-selective electrode (ISE) units. Methods: Serum from 1350 patients was compared to the ABL835 flex and KoneLab. Total calcium was also evaluated on the Dimension Vista 1500 system. Correlations between instruments were assessed by Deming regression and degree of agreement by Cohen's kappa (kappa). Results: Analytical imprecisions for the three ISE units for adjusted Ca2+ (at pH 7.4) was between 0.36% and 2.52%, and for pH between 0.32% and 3.24%. Results were comparable for each ISE unit (r = 0.797-0.917; all P <0.0001) and in high-throughput settings (r= 0.871; P <0.0001). The degree of agreement between instruments was moderate to good (kappa = 0.52-0.77). In contrast, there was a very poor agreement (kappa = -0.14) for total calcium with discrepancy in 53.4% of the samples. Conclusions: The new ISE Module E1200 is comparable with the ABL835 flex and KoneLab 30i and therefore may be used for routine analysis of serum adjusted Ca2+ (at pH 7.4). The measured adjusted Ca2+ (at pH 7.4) was less comparable with very poor agreement to total calcium measured on the Dimension Vista 1500 system.
引用
收藏
页码:704 / 715
页数:12
相关论文
共 50 条
  • [31] NEW TECHNIQUES FOR ION-SELECTIVE MEASUREMENTS OF IONIZED CALCIUM IN SERUM AFTER PH ADJUSTMENT OF AEROBICALLY HANDLED SERA
    SCHWARTZ, HD
    CLINICAL CHEMISTRY, 1976, 22 (04) : 461 - 467
  • [32] Correlation of serum-adjusted calcium with ionized calcium over a 24-h period in patients with adult growth hormone deficiency before and after growth hormone replacement
    White, Helen D.
    Joshi, A. A.
    Ahmad, A. M.
    Durham, B. H.
    Vora, J. P.
    Fraser, W. D.
    ANNALS OF CLINICAL BIOCHEMISTRY, 2010, 47 : 212 - 216
  • [34] Evaluation of the precision and accuracy of an automated sample introduction accessory for the flame atomic absorption spectrometric measurement of calcium in serum
    Epstein, MS
    Buehler, B
    Bullard, MF
    TALANTA, 1998, 47 (01) : 95 - 102
  • [35] Evaluation of Vitamin D (25OHD), Bone Alkaline Phosphatase (BALP), Serum Calcium, Serum Phosphorus, Ionized Calcium in Patients with Mandibular Third Molar Impaction. An Observational Study
    Crincoli, Vito
    Cazzolla, Angela Pia
    Di Comite, Mariasevera
    Lo Muzio, Lorenzo
    Ciavarella, Domenico
    Dioguardi, Mario
    Bizzoca, Maria Eleonora
    Palmieri, Giuseppe
    Fontana, Antonietta
    Giustino, Arcangela
    Di Cosola, Michele
    Vincenzo, Brescia
    Lovero, Roberto
    Di Serio, Francesca
    NUTRIENTS, 2021, 13 (06)
  • [36] The coronary calcium treadmill test: A new approach to the initial workup of patients with suspected coronary artery disease
    Alan Rozanski
    Randy Cohen
    Seth Uretsky
    Journal of Nuclear Cardiology, 2013, 20 : 719 - 730
  • [37] The coronary calcium treadmill test: A new approach to the initial workup of patients with suspected coronary artery disease
    Rozanski, Alan
    Cohen, Randy
    Uretsky, Seth
    JOURNAL OF NUCLEAR CARDIOLOGY, 2013, 20 (05) : 719 - 730
  • [38] EVALUATION OF RADIOMETER ICAL AS A ROUTINE INSTRUMENT FOR SERUM IONIZED CALCIUM AND ITS APPLICATION FOR WHOLE-BLOOD CAPILLARY SAMPLES FROM NEWBORN-INFANTS
    LARSSON, L
    FINNSTROM, O
    NILSSON, B
    OHMAN, S
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1983, 43 : 21 - 26
  • [39] Coronary artery calcium score as a gatekeeper in the non-invasive evaluation of suspected coronary artery disease in symptomatic patients
    Elsemiek M. Engbers
    Jorik R. Timmer
    Jan Paul Ottervanger
    Journal of Nuclear Cardiology, 2017, 24 : 826 - 831
  • [40] Coronary artery calcium score as a gatekeeper in the non-invasive evaluation of suspected coronary artery disease in symptomatic patients
    Engbers, Elsemiek M.
    Timmer, Jorik R.
    Ottervanger, Jan Paul
    JOURNAL OF NUCLEAR CARDIOLOGY, 2017, 24 (03) : 826 - 831