Evaluation of a New Automated Routine Measurement for Serum Adjusted Ionized Calcium (at pH 7.4) in Patients Suspected of Calcium Metabolic Disease

被引:3
|
作者
Kur, Dar K. [1 ]
Hillig, Thore [1 ]
Hansen, Steen, I [1 ]
Goharian, Tina [1 ]
Witte, Majbritt L. [1 ]
Thode, Jorgen [1 ]
机构
[1] Univ Copenhagen, North Zealand Hosp Hilleroed, Dept Clin Biochem, Copenhagen, Denmark
来源
关键词
POINT-OF-CARE; BLOOD-GAS; ALBUMIN; ELECTROLYTE; PLASMA; INTERVALS; ANALYZER; PROTEIN; STORAGE;
D O I
10.1093/jalm/jfaa006
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Total calcium is a less accurate test in predicting ionized calcium (Ca2+) in patients suspected of calcium metabolic disease. Nevertheless, total calcium continues to be used as routine measurement instead of adjusted Ca2+ (at pH 7.4). In the current study we evaluate a new multichannel instrument, the ISE Module E1200 for adjusted Ca2+ (at pH 7.4), containing three different ion-selective electrode (ISE) units. Methods: Serum from 1350 patients was compared to the ABL835 flex and KoneLab. Total calcium was also evaluated on the Dimension Vista 1500 system. Correlations between instruments were assessed by Deming regression and degree of agreement by Cohen's kappa (kappa). Results: Analytical imprecisions for the three ISE units for adjusted Ca2+ (at pH 7.4) was between 0.36% and 2.52%, and for pH between 0.32% and 3.24%. Results were comparable for each ISE unit (r = 0.797-0.917; all P <0.0001) and in high-throughput settings (r= 0.871; P <0.0001). The degree of agreement between instruments was moderate to good (kappa = 0.52-0.77). In contrast, there was a very poor agreement (kappa = -0.14) for total calcium with discrepancy in 53.4% of the samples. Conclusions: The new ISE Module E1200 is comparable with the ABL835 flex and KoneLab 30i and therefore may be used for routine analysis of serum adjusted Ca2+ (at pH 7.4). The measured adjusted Ca2+ (at pH 7.4) was less comparable with very poor agreement to total calcium measured on the Dimension Vista 1500 system.
引用
收藏
页码:704 / 715
页数:12
相关论文
共 50 条
  • [1] ACTUAL IONIZED CALCIUM (AT ACTUAL PH) VS ADJUSTED IONIZED CALCIUM (AT PH 7.4) IN HEMODIALYZED PATIENTS
    RUDNICKI, M
    FROLICH, A
    HAABER, A
    THODE, J
    CLINICAL CHEMISTRY, 1992, 38 (07) : 1384 - 1384
  • [2] ADJUSTED IONIZED CALCIUM (8PH 7.4) COMPARED WITH ACTUAL IONIZED CALCIUM (8ACTUAL PH) IN CAPILLARY BLOOD FOR CLINICAL-EVALUATION OF PATIENTS WITH CALCIUM METABOLIC DISORDERS
    THODE, J
    HOLMEGAARD, SN
    TRANSBOL, I
    FOGHANDERSEN, N
    SIGGAARDANDERSEN, O
    CLINICAL CHEMISTRY, 1990, 36 (06) : 1070 - 1070
  • [3] ADJUSTED IONIZED CALCIUM (AT PH 7.4) AND ACTUAL IONIZED CALCIUM (AT ACTUAL PH) IN CAPILLARY BLOOD COMPARED FOR CLINICAL-EVALUATION OF PATIENTS WITH DISORDERS OF CALCIUM-METABOLISM
    THODE, J
    HOLMEGAARD, SN
    TRANSBOL, I
    FOGHANDERSEN, N
    SIGGAARDANDERSEN, O
    CLINICAL CHEMISTRY, 1990, 36 (03) : 541 - 544
  • [4] SERUM ACTUAL IONIZED CALCIUM COMPARED WITH PH-7.40-ADJUSTED IONIZED CALCIUM
    LARSSON, L
    OHMAN, S
    CLINICAL CHEMISTRY, 1990, 36 (06) : 1063 - 1064
  • [5] IS THE ROUTINE MEASUREMENT OF IONIZED CALCIUM WORTHWHILE IN PATIENTS WITH CANCER
    RIANCHO, JA
    ARJONA, R
    SANZ, J
    OLMOS, JM
    VALLE, R
    BARCELO, JR
    GONZALEZMACIAS, J
    POSTGRADUATE MEDICAL JOURNAL, 1991, 67 (786) : 350 - 353
  • [6] LABORATORY EVALUATION OF NOVA - 2 - A NEW INSTRUMENT FOR THE ROUTINE MEASUREMENT OF IONIZED CALCIUM
    FUCHS, C
    CLINICAL CHEMISTRY, 1980, 26 (07) : 1011 - 1011
  • [7] EVALUATION OF A NEW SEMIAUTOMATIC ELECTRODE SYSTEM FOR SIMULTANEOUS MEASUREMENT OF IONIZED CALCIUM AND PH
    THODE, J
    WANDRUP, J
    AAS, F
    SIGGAARDANDERSEN, O
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1982, 42 (05): : 407 - 415
  • [8] EVALUATION OF MEASUREMENT OF SERUM IONIZED CALCIUM IN UROLOGICAL DISEASES WITH ABNORMAL METABOLISM OF CALCIUM
    YACHIKU, S
    IGUCHI, M
    KURITA, T
    ITATANI, H
    TAKEMOTO, M
    KINOSHITA, K
    JAPANESE JOURNAL OF UROLOGY, 1978, 69 (02): : 165 - 171
  • [9] EVALUATION OF ROUTINE IONIZED CALCIUM DETERMINATION IN CANCER-PATIENTS
    SHEMERDIAK, WP
    KUKREJA, SC
    LAD, TE
    YORK, PAJ
    HENDERSON, WJ
    CLINICAL CHEMISTRY, 1981, 27 (09) : 1621 - 1622
  • [10] COMPARISON OF SERUM TOTAL CALCIUM, ALBUMIN-CORRECTED TOTAL CALCIUM, AND IONIZED CALCIUM IN 1213 PATIENTS WITH SUSPECTED CALCIUM DISORDERS
    THODE, J
    JUULJORGENSEN, B
    BHATIA, HM
    KJAERULFNIELSEN, M
    BARTELS, PD
    FOGHANDERSEN, N
    SIGGAARDANDERSEN, O
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1989, 49 (03): : 217 - 223