摘要
Background: Cardiovascular implantable electronic device (CIED) therapy can reduce morbidity and mortality, but this benefit can be diminished by CIED infection. Currently, there are limited published data on the mortality and cost associated with CIED infection. Methods: We analyzed the risk-adjusted total and incremental admission mortality, long-term mortality, admission length of stay (LOS), and admission cost associated with infection in a retrospective cohort of 200 219 Medicare fee-for-service patients admitted for CIED generator implantation, replacement, or revision between January 1, 2007, and December 31, 2007. Results: There were a total of 5817 admissions with infection. Infection was associated with significant increases in adjusted admission mortality (rate ratios, 4.8-7.7; standardized rates, 4.6%-11.3%) and long-term mortality (rate ratios, 1.6-2.1; standardized rates, 26.5%-35.1%), depending on CIED type. Importantly, approximately half of the incremental long-term mortality occurred after discharge. The adjusted LOS was significantly longer with infection (length of stay mean ratios, 2.5-4.0; standardized length of stay, 15.5-24.3 days), depending on CIED type. The standardized adjusted incremental and total admission costs with infection were $14 360 to $16 498 and $28 676 to $53 349, respectively, depending on CIED type. The largest incremental cost with infection was intensive care, which accounted for more than 40% of the difference. Adjusted long-term mortality rate and cost ratios with infection were significantly greater for pacemakers than for implantable cardioverter/defibrillators or cardiac resynchronization therapy/defibrillator devices. Conclusions: Infection associated with CIED procedures resulted in substantial incremental admission mortality and long-term mortality that varied with the CIED type and occurred, in part, after discharge. Almost half of the incremental admission cost was for intensive care.
引用
收藏
页码:1821 / 1828
页数:8
相关论文
共 50 条
  • [41] Clinical Features and Outcomes of Cardiovascular Implantable Electronic Device Infections Due to Staphylococcal Species
    Le, Katherine Y.
    Sohail, Muhammad R.
    Friedman, Paul A.
    Uslan, Daniel Z.
    Cha, Stephen S.
    Hayes, David L.
    Wilson, Walter R.
    Steckelberg, James M.
    Baddour, Larry M.
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2012, 110 (08): : 1143 - 1149
  • [42] Cardiovascular Implantable Electronic Device Replacement Infections and Prevention: Results from the REPLACE Registry
    Uslan, Daniel Z.
    Gleva, Marye J.
    Warren, David K.
    Mela, Theofanie
    Chung, Mina K.
    Gottipaty, Venkateshwar
    Borge, Richard
    Dan, Dan
    Shinn, Timothy
    Mitchell, Kevin
    Holcomb, Richard G.
    Poole, Jeanne E.
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2012, 35 (01): : 81 - 87
  • [43] Preventing cardiac implantable electronic device infections
    Padfield, Gareth J.
    Steinberg, Christian
    Bennett, Matthew T.
    Chakrabarti, Santabhanu
    Deyell, Marc W.
    Bashir, Jamil
    Krahn, Andrew D.
    [J]. HEART RHYTHM, 2015, 12 (11) : 2344 - 2356
  • [44] Impact of prior aspirin therapy on clinical manifestations of cardiovascular implantable electronic device infections
    Habib, Ammar
    Irfan, Muna
    Baddour, Larry M.
    Le, Katherine Y.
    Anavekar, Nandan S.
    Lohse, Christine M.
    Friedman, Paul A.
    Hayes, David L.
    Wilson, Walter R.
    Steckelberg, James M.
    Sohail, M. Rizwan
    [J]. EUROPACE, 2013, 15 (02): : 227 - 235
  • [45] Cardiac Implantable Electronic Device Removal in Patients with Left Ventricular Assist Device Associated Infections
    Krishnamoorthy, Arun
    Pokorney, Sean D.
    Lewis, Robert K.
    Daubert, James P.
    Greenfield, Ruth A.
    Hegland, Donald D.
    Milano, Carmelo A.
    Rogers, Joseph G.
    Schroder, Jacob N.
    Patel, Chetan B.
    Piccini, Jonathan P.
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2014, 25 (11) : 1199 - 1205
  • [46] Cardiovascular implantable electronic device infective endocarditis
    Scarano, M.
    Pezzuoli, F.
    Torrisi, G.
    Calvagna, G. M.
    Patane, S.
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2014, 173 (03) : E38 - E39
  • [47] The role of intravenous catheters in cardiovascular implantable electronic device infections: Identifying potential targets for prevention
    Othman, Hussein
    Fishbain, Joel T.
    Khatib, Riad
    [J]. AMERICAN JOURNAL OF INFECTION CONTROL, 2013, 41 (04) : 376 - 377
  • [48] Retrospective comparative analysis of cardiovascular implantable electronic device infections with and without the use of antibacterial envelopes
    Hassoun, A.
    Thottacherry, E. D.
    Raja, M.
    Scully, M.
    Azarbal, A.
    [J]. JOURNAL OF HOSPITAL INFECTION, 2017, 95 (03) : 286 - 291
  • [49] Variability in Clinical Features of Early Versus Late Cardiovascular Implantable Electronic Device Pocket Infections
    Welch, Mariko
    Uslan, Daniel Z.
    Greenspon, Arnold J.
    Sohail, Muhammad R.
    Baddour, Larry M.
    Blank, Elisabeth
    Carrillo, Roger G.
    Danik, Stephan B.
    Del Rio, Ana
    Hellinger, Walter
    Le, Katherine Y.
    Miro, Jose M.
    Naber, Christoph
    Peacock, James E.
    Vikram, Holenarasipur R.
    Tseng, Chi-Hong
    Prutkin, Jordan M.
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2014, 37 (08): : 955 - 962
  • [50] Detection of Cardiovascular Implantable Electronic Device Infections with Sonication Following Lead Extraction and Generator Change
    Nguyen, B. L.
    Oliva, A.
    Di Giamberardino, A. L.
    Mascellino, M. T.
    Cipolla, A.
    Alessandri, N.
    Gaudio, C.
    Ciccaglioni, A.
    Mastroianni, C. M.
    Vullo, V.
    [J]. EUROPEAN HEART JOURNAL, 2015, 36 : 401 - 401