Subjective scaling of hand-arm vibration

被引:1
|
作者
Maeda, Setsuo [1 ]
Shibata, Nobuyuki [1 ]
机构
[1] NIOSH, Measurment & Control Work Environm Res Grp, Tama Ku, Kawasaki, Kanagawa 2148585, Japan
关键词
subjective comfort; hand-arm vibration; category judgment method; ISO; 5349-1; frequency-weighting;
D O I
10.2486/indhealth.46.118
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The purpose of this research was to establish a scale for comfort with regard to handarm vibration using the category judgment method and to validate the frequency-weighting method of the ISO 5349-1 standard. Experiments were conducted using random signals as stimuli. These stimuli consisted of three types of signal, namely designated stimulus F, with flat power spectrum density (PSD) ranging from I to 1,000 Hz, stimulus H with PSD which became 20 dB higher at 1,000 Hz than at I Hz, and stimulus L that had a PSD 20 dB lower at 1,000 Hz. These stimuli were selected from the specific spectrum patterns of hand-held vibration tools. These signals were modified by the Wh frequency weighting in accordance with ISO 5349-1, and the R.M.S. values were adjusted to be equal. In addition, the signal levels were varied over a range of five steps to create 15 kinds of individual stimuli. The subjects sat in front of a vibrator and grasped the mounted handle which exposed them to vertical vibrations after which they were asked to choose a numerical category to best indicate their perceived level of comfort (or otherwise) during each stimulus. From the experimental results of the category judgment method, the relationship between the psychological values and the frequency-weighted R.M.S. acceleration according to the ISO 5349-1 standard was obtained. It was found that the subjective response scaling of hand-arm vibration can be used for design-objective values of hand-held tool vibration.
引用
收藏
页码:118 / 124
页数:7
相关论文
共 50 条
  • [31] Characteristics of vibration transmission in the hand-arm system and subjective response during field operation of a hand tractor
    Dewanyan, K. N.
    Tewari, V. K.
    BIOSYSTEMS ENGINEERING, 2008, 100 (04) : 535 - 546
  • [32] Cold intolerance and hand-arm vibration syndrome
    Cooke, Roger Anthony
    Lawson, Ian James
    OCCUPATIONAL MEDICINE-OXFORD, 2022, 72 (03): : 152 - 153
  • [33] The simulation of vibration attenuation in the hand-arm sistem
    1600, Politechnica University of Bucharest (75):
  • [34] Exposure to Hand-Arm Vibration in the Australian Workforce
    Lewkowski, Kate
    Ytterstad, Elinor
    Pugliese, Matthew J.
    McCausland, Kahlia
    Heyworth, Jane S.
    Li, Ian W.
    Pettersson, Hans
    Williams, Warwick
    Fritschi, Lin
    ANNALS OF WORK EXPOSURES AND HEALTH, 2021, 65 (06) : 659 - 667
  • [35] SENSORINEURAL STAGES OF THE HAND-ARM VIBRATION SYNDROME
    BRAMMER, AJ
    TAYLOR, W
    LUNDBORG, G
    SCANDINAVIAN JOURNAL OF WORK ENVIRONMENT & HEALTH, 1987, 13 (04) : 279 - 283
  • [36] PATHOPHYSIOLOGICAL AND HYGIENIC ASPECTS OF HAND-ARM VIBRATION
    PYYKKO, I
    STARCK, J
    SCANDINAVIAN JOURNAL OF WORK ENVIRONMENT & HEALTH, 1986, 12 (04) : 237 - 241
  • [37] Hand-arm vibration measurements: Why bother?
    Wray, Steve
    Acoustics Bulletin, 2006, 31 (05): : 29 - 31
  • [38] EFFECTS OF IMPULSE VIBRATION ON THE HAND-ARM SYSTEM
    DUPUIS, H
    SCHAFER, N
    SCANDINAVIAN JOURNAL OF WORK ENVIRONMENT & HEALTH, 1986, 12 (04) : 320 - 322
  • [39] A mouse model for hand-arm vibration syndrome
    Lindsley, WG
    Jensen, N
    Kommineni, C
    SECOND JOINT EMBS-BMES CONFERENCE 2002, VOLS 1-3, CONFERENCE PROCEEDINGS: BIOENGINEERING - INTEGRATIVE METHODOLOGIES, NEW TECHNOLOGIES, 2002, : 448 - 449
  • [40] The clinical assessment of hand-arm vibration syndrome
    Pelmear, PL
    OCCUPATIONAL MEDICINE-OXFORD, 2003, 53 (05): : 337 - 341