The Influence of Cochlear Implant Electrode Position on Performance

被引:50
|
作者
van der Marel, Kim S. [1 ]
Briaire, Jeroen J. [1 ]
Verbist, Berit M. [2 ,3 ]
Muurling, Tjeerd J. [1 ]
Frijns, Johan H. M. [1 ]
机构
[1] Leiden Univ, Med Ctr, Dept Otorhinolaryngol, NL-2300 RC Leiden, Netherlands
[2] Leiden Univ, Med Ctr, Dept Radiol, NL-2300 RC Leiden, Netherlands
[3] Radboud Univ Nijmegen, Med Ctr, Dept Radiol, NL-6525 ED Nijmegen, Netherlands
关键词
Cochlear implantation; Electrode position; Insertion depth; Modiolus proximity; Performance scores; Phoneme scores; Word scores; SPEECH-PERCEPTION; INSERTION DEPTH; DEEP INSERTION; ADULTS; MORPHOLOGY; HEARING; ARRAY; DEAFNESS; OUTCOMES; CII;
D O I
10.1159/000377616
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Objectives: To study the relation between variables related to cochlear implant electrode position and speech perception performance scores in a large patient population. Design: The study sample consisted of 203 patients implanted with a CII or HiRes90K implant with a HiFocus 1 or 1J electrode of Advanced Bionics. Phoneme and word score averages for the 1- and 2-year follow-up were calculated for 41 prelingually deaf and 162 postlingually deaf patients. Analyses to reveal correlations between these performance outcomes and 6 position-related variables (angle of most basal electrode contact, surgical insertion angle, surgical insertion, wrapping factor, angular insertion depth, linear insertion depth) were executed. The scalar location, as an indication for the presence of intracochlear trauma, and modiolus proximity beyond the basal turn were not evaluated in this study. In addition, different patient-specific variables (age at implantation, age at onset of hearing loss, duration of deafness, preoperative phoneme and word scores) were tested for correlation with performance. Results: The performance scores of prelingual patients were correlated with age at onset of hearing loss, duration of deafness and preoperative scores. For the postlingual patients, performance showed correlations with all 5 patient-specific variables. None of the 6 position-related variables influenced speech perception in cochlear implant patients. Conclusions: Although several patient-specific variables showed correlations with speech perception outcomes, not one of the studied angular and linear position-related variables turned out to have a demonstrable influence on performance. (C) 2015 S. Karger AG, Basel
引用
收藏
页码:202 / 211
页数:10
相关论文
共 50 条
  • [21] How Cochlear Implant Position and Perilymph Composition affect Stimulation Electrode Impedance
    Sehlmeyer, Merle
    Biebighaeuser, Julian
    Klinger, Britta
    Bhaysar, Mit B.
    Maier, Hannes
    Zimmermann, Stefan
    2024 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS, MEMEA 2024, 2024,
  • [22] The influence of age at implantation on performance with a cochlear implant in children
    Kileny, PR
    Zwolan, TA
    Ashbaugh, C
    OTOLOGY & NEUROTOLOGY, 2001, 22 (01) : 42 - 46
  • [23] Influence of the Cochlear Implant Electrode Array Placement on the Current Spread in the Cochlea
    Schaefer, Friederike
    Enke, Joerg
    Boehnke, Frank
    Hemmert, Werner
    Bai, Siwei
    2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 6145 - 6148
  • [24] Intra-Cochlear Electrode Position Impacts the Preservation of Residual Hearing in an Animal Model of Cochlear Implant Surgery
    Meuser, Max
    Schwitzer, Susanne
    Thiele, Mario
    Boyle, Patrick
    Ernst, Arne
    Basta, Dietmar
    AUDIOLOGY AND NEUROTOLOGY, 2025, 30 (01) : 34 - 44
  • [25] Factors that influence performance in pediatric cochlear implant recipients with cochlear nerve deficiency
    Thompson, Nicholas J.
    Park, Lisa R.
    O'Connell, Brendan P.
    Zdanski, Carlton J.
    Brown, Kevin D.
    Anderson, Melissa R.
    COCHLEAR IMPLANTS INTERNATIONAL, 2024, 25 (03) : 191 - 196
  • [26] The Summating Potential Is a Reliable Marker of Electrode Position in Electrocochleography: Cochlear Implant as a Theragnostic Probe
    Helmstaedter, Victor
    Lenarz, Thomas
    Erfurt, Peter
    Kral, Andrej
    Baumhoff, Peter
    EAR AND HEARING, 2018, 39 (04): : 687 - 700
  • [27] Evaluation of cochlear implant electrode scalar position by 3 Tesla magnet resonance imaging
    C. Riemann
    L. U. Scholtz
    H. B. Gehl
    M. Schürmann
    H. Sudhoff
    I. Todt
    Scientific Reports, 11
  • [28] Evaluation of cochlear implant electrode scalar position by 3 Tesla magnet resonance imaging
    Riemann, C.
    Scholtz, L. U.
    Gehl, H. B.
    Schuermann, M.
    Sudhoff, H.
    Todt, I.
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [29] Pulse rate matching by cochlear implant patients: Effects of loudness randomization and electrode position
    Pijl, S
    EAR AND HEARING, 1997, 18 (04): : 316 - 325
  • [30] In situ measurement of cochlear implant electrode position with spiral CT image unwrapping and deblurring
    Wang, G
    Vannier, MW
    Skinner, MW
    Harding, GW
    RADIOLOGY, 1996, 201 : 239 - 239