Intermittent-contact scanning capacitance microscopy imaging and modeling for overlay metrology

被引:0
|
作者
Mayo, S [1 ]
Kopanski, JJ [1 ]
Guthrie, WF [1 ]
机构
[1] NIST, Div Semicond Elect, Gaithersburg, MD 20899 USA
关键词
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Overlay measurements of the relative alignment between sequential layers are one of the most critical issues for integrated circuit (IC) lithography. We have implemented on an AFM platform a new intermittent-contact scanning capacitance microscopy (IC-SCM) mode that is sensitive to the tip proximity to an IC interconnect, thus making it possible to image conductive structures buried under planarized dielectric layers. Such measurements can be used to measure IC metal-to-resist lithography overlay. The AFM conductive cantilever probe oscillating in a vertical plane was driven at frequency omega, below resonance. By measuring the tip-to-sample capacitance, the SCM signal is obtained as the difference in capacitance, Delta C(omega), at the amplitude extremes. Imaging of metallization structures was obtained with a bars-in-bars aluminum structure embedded in a planarized dielectric layer 1 mu m thick. We have also modeled, with a two-dimensional (2D) electrostatic field simulator, IC-SCM overlay data of a metallization structure buried under a planarized dielectric having a patterned photoresist layer deposited on it. This structure, which simulates the metal-to-resist overlay between sequential IC levels, allows characterization of the technique sensitivity. The capacitance profile across identical size electrically isolated or grounded metal lines embedded in a dielectric was shown to be different. The floating line shows capacitance enhancement at the line edges, with a minimum at the line center. The grounded line shows a single capacitance maximum located at the line center, with no edge enhancement. For identical line dimensions, the capacitance is significantly larger for grounded lines making them easier to image. A nonlinear regression algorithm was developed to extract line center and overlay parameters with approximately 3 nm resolution at the 95% confidence level, showing the potential of this technique for sub-micrometer critical dimension metrology. Symmetric test structures contribute to facilitate overlay data extraction.
引用
收藏
页码:567 / 572
页数:6
相关论文
共 50 条
  • [21] Measuring average tip-sample forces in intermittent-contact (tapping) force microscopy in air
    Fain, SC
    Barry, KA
    Bush, MG
    Pittenger, B
    Louie, RN
    APPLIED PHYSICS LETTERS, 2000, 76 (07) : 930 - 932
  • [22] Nanoscale intermittent contact-scanning electrochemical microscopy
    Lazenby, Robert A.
    McKelvey, Kim
    Peruffo, Massimo
    Baghdadi, Marc
    Unwin, Patrick R.
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2013, 17 (12) : 2979 - 2987
  • [23] Nanoscale intermittent contact-scanning electrochemical microscopy
    Robert A. Lazenby
    Kim McKelvey
    Massimo Peruffo
    Marc Baghdadi
    Patrick R. Unwin
    Journal of Solid State Electrochemistry, 2013, 17 : 2979 - 2987
  • [24] Analysis of dopant metrology using Scanning Capacitance Microscopy and Transmission Electron Microscopy as complementary techniques
    Natarajan, M
    Sheng, TT
    Pey, KL
    Lee, YP
    Radhakrishnan, MK
    PROCEEDINGS OF THE 1997 6TH INTERNATIONAL SYMPOSIUM ON THE PHYSICAL & FAILURE ANALYSIS OF INTEGRATED CIRCUITS, 1997, : 86 - 91
  • [25] Current measurements in the intermittent-contact mode of atomic force microscopy using the Fourier method: a feasibility analysis
    Uluutku, Berkin
    Solares, Santiago D.
    BEILSTEIN JOURNAL OF NANOTECHNOLOGY, 2020, 11 : 453 - 465
  • [26] Intermittent contact scanning force microscopy: The role of the liquid necks
    Luna, M
    Colchero, J
    Baro, AM
    APPLIED PHYSICS LETTERS, 1998, 72 (26) : 3461 - 3463
  • [27] Intermittent-contact capacitance spectroscopy - A new method for determining C(V) curves with sub-micron lateral resolution
    Biberger, Roland
    Benstetter, Guenther
    Goebel, Holger
    Hofer, Alexander
    MICROELECTRONICS RELIABILITY, 2010, 50 (9-11) : 1511 - 1513
  • [28] Scanning capacitance microscopy imaging of state-of-the-art MOSFETs
    Kleiman, RN
    O'Malley, ML
    Baumann, FH
    Garno, JP
    Timp, GL
    MICROSCOPY OF SEMICONDUCTING MATERIALS 1999, PROCEEDINGS, 1999, (164): : 615 - 624
  • [29] Scanning capacitance microscopy measurements and modeling for dopant profiling of silicon
    Kopanski, JJ
    Marchiando, JF
    Lowney, JR
    SEMICONDUCTOR CHARACTERIZATION: PRESENT STATUS AND FUTURE NEEDS, 1996, : 308 - 312
  • [30] Experimental aspects and modeling for quantitative measurements in scanning capacitance microscopy
    Giannazzo, F
    Goghero, D
    Raineri, V
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 2004, 22 (05): : 2391 - 2397