Long-term outcome of patients with drug-refractory atrial flutter and fibrillation after single- and dual-site right atrial pacing for arrhythmia prevention

被引:154
|
作者
Delfaut, P
Saksena, S
Prakash, A
Krol, RB
机构
[1] Atlantic Hlth Syst, Eastern Heart Inst, Arrhythmia & Pacemaker Serv, Passaic, NJ USA
[2] Electrophysiol Res Fdn, Millburn, NJ USA
关键词
D O I
10.1016/S0735-1097(98)00489-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. An initial crossover study comparing dual- and single-site right atrial pacing was performed followed by a long term efficacy and safety evaluation of dual site right atrial pacing in patients with drug-refractory atrial fibrillation (AF). Also examined was the efficacy of two single-site right atrial pacing modes (high right atrium and coronary sinus ostium) and the long term need for cardioversion, antithrombotic and antiarrhythmic drug therapies during dual-site atrial pacing. Methods. Thirty consecutive patients with drug refractory symptomatic AF and documented primary or drug-induced bra dycardia were implanted with a dual chamber rate-responsive pacemaker and two atrial leads. Single site atrial pacing was performed at the high right atrium or the coronary sinus ostium. Continuous atrial pacing was maintained. Results. Mean arrhythmia-free intervals increased from 9 +/- 10 days in the control period preceding implant to 143 +/- 110 days (p < 0.0001) in single-site right atrial pacing and 195 +/- 96 days in dual-site right atrial pacing (p < 0.005 versus single site pacing and p < 0.0001 versus control). Dual site sight atrial pacing significantly increased the proportion of patients free of AF recurrence (89%) as compared to single site right atrial pacing (62%, p = 0.02). High right atrial pacing and coronary sinus ostial pacing had similar efficacy for AF prevention. Effective rhythm control was achieved in 86% of patients during dual right atrial pacing. Seventy eight percent of patients at 1 year and 56% at 3 years remained free of symptomatic AF. The need for cardioversion was reduced after pacemaker implant (p < 0.05) and antithrombotic therapy was reduced (p < 0.06) without any thromboembolic event. Coronary sinus ostial lead dislodgement was not observed after discharge. Conclusions. Atrial pacing in combination with antiarrhythmic drugs eliminates or markedly reduces recurrent AF. Prevention of AF is enhanced by dual site right atrial pacing. High right atrial and coronary sinus ostial pacing do not differ in efficacy. Dual-site right atrial pacing is safe, achieves long term rhythm control in most patients, decreases the need for cardioversion, and antithrombotic therapy can be selectively reduced. (J Am Coll Cardiol 1998;32:1900-8) (C) 1998 by the American College of Cardiology.
引用
收藏
页码:1900 / 1908
页数:9
相关论文
共 50 条
  • [21] Drug-refractory atrial fibrillation associated with hyperthyroidism: its prevalence and long-term outcome after catheter ablation
    Machino, T.
    Tada, H.
    Sekiguchi, Y.
    Yamasaki, H.
    Kuroki, K.
    Igarashi, M.
    Yoshida, K.
    Aonuma, K.
    EUROPEAN HEART JOURNAL, 2012, 33 : 987 - 988
  • [22] Prevalence and Influence of Hyperthyroidism on the Long-Term Outcome of Catheter Ablation for Drug-Refractory Atrial Fibrillation
    Machino, Takeshi
    Tada, Hiroshi
    Sekiguchi, Yukio
    Yamasaki, Hiro
    Kuroki, Kenji
    Igarashi, Miyako
    Naruse, Yoshihisa
    Nakano, Emi
    Ito, Yoko
    Kaneshiro, Takashi
    Yoshida, Kentaro
    Aonuma, Kazutaka
    CIRCULATION JOURNAL, 2012, 76 (11) : 2546 - 2551
  • [23] Long-term outcome of atrial resynchronisation for treatment of drug refractory atrial fibrillation
    Sankaranarayanan, R.
    James, M. A.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2007, 18 (01) : 130 - 130
  • [24] Evaluation of bi-atrial pacing and single site right atrial pacing for the prevention of atrial fibrillation
    Enjoji, Y
    Sugi, K
    Noro, M
    Nakae, T
    Tezuka, N
    Takami, M
    Kawase, A
    Kumagai, K
    Sakai, T
    Ikeda, T
    Yamaguchi, T
    CIRCULATION JOURNAL, 2002, 66 (01) : 70 - 74
  • [25] BIATRIAL SYNCHRONOUS PACING - A NEW APPROACH FOR PREVENTION OF DRUG-REFRACTORY ATRIAL-FLUTTER
    DAUBERT, C
    GRAS, D
    LECLERCQ, C
    BAISSET, JM
    PAVIN, D
    MABO, P
    CIRCULATION, 1995, 92 (08) : 2539 - 2539
  • [26] Evaluation of biatrial pacing, right atrial pacing, and no pacing in patients with drug refractory atrial fibrillation
    Levy, T
    Walker, S
    Rochelle, J
    Paul, V
    AMERICAN JOURNAL OF CARDIOLOGY, 1999, 84 (04): : 426 - 429
  • [27] Resynchronization of atrial compartments after catheter maze with dual-site right atrial pacing
    Filipecki, A
    Saksena, S
    Prakash, A
    EUROPEAN HEART JOURNAL, 2002, 23 : 282 - 282
  • [28] Is dual site better than single site atrial pacing in the prevention of atrial fibrillation?
    Leclercq, JF
    De Sisti, A
    Fiorello, P
    Halimi, F
    Manot, S
    Attuel, P
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2000, 23 (12): : 2101 - 2107
  • [29] Dynamic and dual-site atrial pacing in the prevention of atrial fibrillation: The STimolazione atrial DInamica Multisito (STADIM) study
    De Simone, Antonio
    Senatore, Gaetano
    Donnici, Giovanni
    Turco, Pietro
    Romano, Enrico
    Gazzola, Carlo
    Stabile, G.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2007, 30 : S71 - S74
  • [30] A prospective, long-term, randomized, controlled study of alternate-site right atrial pacing for prevention of atrial fibrillation
    Leong, D.
    Leitch, J.
    O'donnell, D.
    Sanders, P.
    Young, G. D.
    EUROPEAN HEART JOURNAL, 2010, 31 : 414 - 415