Female and male serum reference intervals for challenging sex and precursor steroids by liquid chromatography - tandem mass spectrometry

被引:30
|
作者
Mezzullo, Marco
Pelusi, Carla
Fazzini, Alessia
Repaci, Andrea
Di Dalmazi, Guido
Gambineri, Alessandra
Pagotto, Uberto
Fanelli, Flaminia
机构
[1] Univ Bologna, S Orsola Policlin, Dept Med & Surg Sci, Endocrinol Unit, Via Massarenti 9, I-40138 Bologna, Italy
[2] Univ Bologna, S Orsola Policlin, Dept Med & Surg Sci, Ctr Appl Biomed Res, Via Massarenti 9, I-40138 Bologna, Italy
关键词
estrogen; dihydrotestosterone; 17-hydroxypregnenolone; LC-MS/MS; immunoassays; reference intervals; LC-MS/MS; POSTMENOPAUSAL WOMEN; ESTRONE LEVELS; HUMAN PLASMA; ESTRADIOL; TESTOSTERONE; ASSAY; DIHYDROTESTOSTERONE; DERIVATIZATION; MEN;
D O I
10.1016/j.jsbmb.2019.105538
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Measuring some sex and precursor steroids is still challenging even by liquid chromatography - tandem mass spectrometry (LC-MS/MS), and few normal values are available. We developed a LC-MS/MS method for estradiol, estrone, dihydrotestosterone and 17-hydroxypregnenolone measurement, compared it with direct immunoassays, and generated sex, age, menopausal and menstrual status specific reference intervals. Liquid-liquid extraction was optimized on 300 mu L serum spiked with isotopic internal standards. A 2D-LC system allowed online purification and separation in 11 min run. Electrospray ionization was enhanced by ammonium fluoride. MS-detection was obtained by multiple reaction monitoring. Direct ECLIA for estradiol (n = 80) and RIA for estrone (n = 41) were compared with LC-MS/MS. Reference values were estimated in healthy, lean women in reproductive age (n = 118), menopausal women (n = 33) and men (n = 159). The assay showed satisfying imprecision, trueness, recovery and selectivity. Adequate functional sensitivity was achieved for measuring estrone (18.1 pmol/L) and 17-hydroxypregnenolone (117 pmol/L) in all subjects, and estradiol (35.9 pmol/L) and dihydrotestosterone (134 pmol/L) in women in reproductive age and men, but not in menopausal women. Compared with LC-MS/MS, immunoassays showed good agreement for estradiol but severe disagreement for estrone. Estrogens exhibited sex, menopausal and menstrual variations. Dihydrotestosterone and 17-hydroxypregnenolone depended on sex and menopause, the latter also declining with age in men. Strictly defined reference intervals in the adult female and male population were generated for challenging steroids such as estrogens, dihydrotestosterone and 17-hydroxypregnenolone by a novel LC-MS/MS method. Our achievement can be used to deepen the comprehension of several endocrine diseases.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Age and seasonal variation and establishment of reference intervals for water-soluble vitamins determined by liquid chromatography tandem mass spectrometry
    Tong, Wei-Wei
    Tong, Guang-Hui
    Yang, Meng-Han
    Qin, Xiao-Song
    NUTRITION, 2022, 95
  • [42] Direct measurement of free estradiol in human serum by equilibrium dialysis-liquid chromatography-tandem mass spectrometry and reference intervals of free estradiol in women
    Ray, Julie A.
    Kushnir, Mark M.
    Bunker, Ashley
    Rockwood, Alan L.
    Meikle, A. Wayne
    CLINICA CHIMICA ACTA, 2012, 413 (11-12) : 1008 - 1014
  • [43] Implementation of a Liquid Chromatography Tandem Mass Spectrometry Assay for Eight Adrenal C-21 Steroids and Pediatric Reference Data
    Kulle, Alexandra E.
    Welzel, Maik
    Holterhus, Paul-Martin
    Riepe, Felix G.
    HORMONE RESEARCH IN PAEDIATRICS, 2013, 79 (01): : 22 - 31
  • [44] Liquid chromatography-tandem mass spectrometry for the quantification of total testosterone in serum
    Shi, H.
    Carlow, D.
    CLINICAL CHEMISTRY, 2008, 54 (06) : A15 - A16
  • [45] Analysis of thyroid hormones in serum by liquid chromatography-tandem mass spectrometry
    Wang, Dongli
    Stapleton, Heather M.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 397 (05) : 1831 - 1839
  • [46] Determination of ribavirin in human serum using liquid chromatography tandem mass spectrometry
    van der Lijke, Henk
    Alffenaar, Jan-Willem C.
    Kok, Wim Th.
    Greijdanus, Ben
    Uges, Donald R. A.
    TALANTA, 2012, 88 : 385 - 390
  • [47] Determination of Lamotrigine in Human Serum By Liquid Chromatography-Tandem Mass Spectrometry
    Lee, W.
    Yoon, S.
    Park, Y.
    Suh, B.
    Kwon, O. H.
    CLINICAL CHEMISTRY, 2009, 55 (06) : A261 - A261
  • [48] Serum cholesterol measured by isotope dilution liquid chromatography tandem mass spectrometry
    Zhou, Weiyan
    Li, Hongxia
    Dong, Jun
    Wang, Shu
    Yang, Ruiyue
    Zhang, Chuanbao
    Chen, Wenxiang
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 (04) : 669 - 676
  • [49] Determination of olanzapine in human plasma and serum by liquid chromatography tandem mass spectrometry
    Berna, M
    Shugert, R
    Mullen, J
    JOURNAL OF MASS SPECTROMETRY, 1998, 33 (10): : 1003 - 1008
  • [50] Analysis of thyroid hormones in serum by liquid chromatography-tandem mass spectrometry
    Dongli Wang
    Heather M. Stapleton
    Analytical and Bioanalytical Chemistry, 2010, 397 : 1831 - 1839