Female and male serum reference intervals for challenging sex and precursor steroids by liquid chromatography - tandem mass spectrometry

被引:30
|
作者
Mezzullo, Marco
Pelusi, Carla
Fazzini, Alessia
Repaci, Andrea
Di Dalmazi, Guido
Gambineri, Alessandra
Pagotto, Uberto
Fanelli, Flaminia
机构
[1] Univ Bologna, S Orsola Policlin, Dept Med & Surg Sci, Endocrinol Unit, Via Massarenti 9, I-40138 Bologna, Italy
[2] Univ Bologna, S Orsola Policlin, Dept Med & Surg Sci, Ctr Appl Biomed Res, Via Massarenti 9, I-40138 Bologna, Italy
关键词
estrogen; dihydrotestosterone; 17-hydroxypregnenolone; LC-MS/MS; immunoassays; reference intervals; LC-MS/MS; POSTMENOPAUSAL WOMEN; ESTRONE LEVELS; HUMAN PLASMA; ESTRADIOL; TESTOSTERONE; ASSAY; DIHYDROTESTOSTERONE; DERIVATIZATION; MEN;
D O I
10.1016/j.jsbmb.2019.105538
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Measuring some sex and precursor steroids is still challenging even by liquid chromatography - tandem mass spectrometry (LC-MS/MS), and few normal values are available. We developed a LC-MS/MS method for estradiol, estrone, dihydrotestosterone and 17-hydroxypregnenolone measurement, compared it with direct immunoassays, and generated sex, age, menopausal and menstrual status specific reference intervals. Liquid-liquid extraction was optimized on 300 mu L serum spiked with isotopic internal standards. A 2D-LC system allowed online purification and separation in 11 min run. Electrospray ionization was enhanced by ammonium fluoride. MS-detection was obtained by multiple reaction monitoring. Direct ECLIA for estradiol (n = 80) and RIA for estrone (n = 41) were compared with LC-MS/MS. Reference values were estimated in healthy, lean women in reproductive age (n = 118), menopausal women (n = 33) and men (n = 159). The assay showed satisfying imprecision, trueness, recovery and selectivity. Adequate functional sensitivity was achieved for measuring estrone (18.1 pmol/L) and 17-hydroxypregnenolone (117 pmol/L) in all subjects, and estradiol (35.9 pmol/L) and dihydrotestosterone (134 pmol/L) in women in reproductive age and men, but not in menopausal women. Compared with LC-MS/MS, immunoassays showed good agreement for estradiol but severe disagreement for estrone. Estrogens exhibited sex, menopausal and menstrual variations. Dihydrotestosterone and 17-hydroxypregnenolone depended on sex and menopause, the latter also declining with age in men. Strictly defined reference intervals in the adult female and male population were generated for challenging steroids such as estrogens, dihydrotestosterone and 17-hydroxypregnenolone by a novel LC-MS/MS method. Our achievement can be used to deepen the comprehension of several endocrine diseases.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Determination of anabolic steroids in bovine serum by liquid chromatography-tandem mass spectrometry
    Kaklamanos, George
    Theodoridis, Georgios A.
    Dabalis, Themistoldis
    Papadoyannis, Ioannis
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (02): : 225 - 229
  • [3] Liquid chromatography tandem mass spectrometry for analysis of steroids in clinical laboratories
    Kushnir, Mark M.
    Rockwood, Alan L.
    Roberts, William L.
    Yue, Bingfang
    Bergquist, Jonas
    Meikle, A. Wayne
    CLINICAL BIOCHEMISTRY, 2011, 44 (01) : 77 - 88
  • [4] Liquid chromatography-tandem mass spectrometry of some anabolic steroids
    Joos, PE
    Van Ryckeghem, M
    ANALYTICAL CHEMISTRY, 1999, 71 (20) : 4701 - 4710
  • [5] Measurement of sex steroids in murine blood and reproductive tissues by liquid chromatography-tandem mass spectrometry
    McNamara, K. M.
    Harwood, D. T.
    Simanainen, U.
    Walters, K. A.
    Jimenez, M.
    Handelsman, D. J.
    JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 2010, 121 (3-5): : 611 - 618
  • [6] Serum testosterone in females by liquid chromatography tandem mass spectrometry
    Boyder, C.
    Joseph, J.
    Lim, E. M.
    Tanner, M.
    CLINICA CHIMICA ACTA, 2010, 411 (11-12) : 902 - 902
  • [7] Quantification of serum caspofungin by liquid chromatography tandem mass spectrometry
    Streit, F
    Cremer, S
    Schüttrumpf, S
    Ohmstede, B
    Binder, C
    Oellerich, M
    Binder, L
    THERAPEUTIC DRUG MONITORING, 2005, 27 (02) : 255 - 255
  • [8] Liquid Chromatography-Tandem Mass Spectrometry Assay for Androstenedione, Dehydroepiandrosterone, and Testosterone with Pediatric and Adult Reference Intervals
    Kushnir, Mark M.
    Blamires, Takara
    Rockwood, Alan L.
    Roberts, William L.
    Yue, Bingfang
    Erdogan, Evrim
    Bunker, Ashley M.
    Meikle, A. Wayne
    CLINICAL CHEMISTRY, 2010, 56 (07) : 1138 - 1147
  • [9] Determination of endogenous steroids in urine by liquid chromatography-tandem mass spectrometry
    Wang Mengye
    Xiang Ping
    Yan Hui
    Shen Baohua
    Shen Min
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2008, 26 (01) : 10 - 14
  • [10] High-performance liquid chromatography - Tandem mass spectrometry of cardiac steroids
    Higashi, T
    Nakayama, N
    Shimada, K
    Kasai, H
    Nakazawa, H
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1999, 22 (15) : 2283 - 2296