Energy-filtering transmission electron microscopy (EFTEM) in the elemental analysis of pseudoexfoliative material

被引:22
|
作者
Schlötzer-Schrehardt, U
Kortje, KH
Erb, C
机构
[1] Univ Erlangen Nurnberg, Dept Ophthalmol, D-91054 Erlangen, Germany
[2] Univ Hohenheim, Inst Zool, D-7000 Stuttgart, Germany
[3] Hannover Med Sch, Hannover, Germany
关键词
energy filtering transmission electron microscopy (EFTEM); electron spectroscopic imaging (ESI); electron energy loss spectroscopy (EELS); pseudoexfoliation syndrome; elemental analysis;
D O I
10.1076/ceyr.22.2.154.5522
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To obtain more information on the basic nature of the pathological matrix product accumulating in pseudoexfoliation (PEX) syndrome by analyzing its elemental composition at the subcellular level. Methods. Energy-filtering transmission electron microscopy (EFTEM), combining the two microanalytical techniques of electron spectroscopic imaging (ESI) and energy-loss spectroscopy (EELS), were performed on ultrathin sections of lens specimens with PEX syndrome using a transmission electron microscope equipped with an integrated electron energy filter. EFTEM is based on inner shell ionization of elements present in the sample giving rise to characteristic signals in well-defined energy-loss regions. The EEL-spectra, demonstrating the presence of a particular element by its specific electron energy-loss edge, were recorded with an integrated scintillator-photomultiplier-system. ESI generated graphic images of elemental localization in the sections after a process of background correction with an IBAS image analysis program. Energy-dispersive X-ray (EDX) analysis of PEX deposits on hydrated lenses was conducted by variable pressure scanning electron microscopy. Results. The ESI element distribution images of both intracapsular and supracapsular PEX material displayed high signals for nitrogen, sulfur, calcium, chlorine, and zinc in clear association with the PEX fibrils. The corresponding EEL-spectra confirmed the data obtained by ESI and showed the presence of the element-specific energy-loss edges. The presence of these elements in PEX fibrils was further confirmed by EDX analysis. No specific signals were obtained for phosphorus, oxygen, or aluminum. Conclusions. This study demonstrates the presence of nitrogen, sulfur, chlorine, zinc, and calcium both in mature and in aggregating PEX fibrils of the lens capsule. EFTEM proved to be a highly sensitive method for the microanalytical study of biological material with unknown composition, such as PEX material, at the subcellular level.
引用
收藏
页码:154 / 162
页数:9
相关论文
共 50 条
  • [41] Mass determination in an energy-filtering transmission electron microscope
    Feja, B
    Durrenberger, M
    Muller, S
    Reichelt, R
    Aebi, U
    EUROPEAN JOURNAL OF CELL BIOLOGY, 1997, 74 : 94 - 94
  • [42] High-Energy Electron Scattering in Thick Samples Evaluated by Bright-Field Transmission Electron Microscopy, Energy-Filtering Transmission Electron Microscopy, and Electron Tomography
    Hayashida, Misa
    Malac, Marek
    MICROSCOPY AND MICROANALYSIS, 2022, 28 (03) : 659 - 671
  • [43] Cytochemical energy-filtering transmission electron microscopy of mitochondrial free radical formation in paraquat cytotoxicity
    Hirai, KI
    Pan, JH
    Shimada, H
    Izuhara, T
    Kurihara, T
    Moriguchi, K
    JOURNAL OF ELECTRON MICROSCOPY, 1999, 48 (03): : 289 - 296
  • [44] Direct whole-mount imaging of fungal spores by energy-filtering transmission electron microscopy
    Kim, Ki Woo
    MICRON, 2009, 40 (02) : 279 - 283
  • [45] Localization of iron stores and iron binding sites in blood cells of five different priapulid species by energy-filtering electron microscopy (EFTEM)
    Triebskorn, R
    Higgins, R
    Kortje, KH
    Storch, V
    JOURNAL OF TRACE AND MICROPROBE TECHNIQUES, 1996, 14 (04): : 775 - 797
  • [46] Bactericidal actions of a silver ion solution on Escherichia coli, studied by energy-filtering transmission electron microscopy and proteomic analysis
    Yamanaka, M
    Hara, K
    Kudo, J
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2005, 71 (11) : 7589 - 7593
  • [47] Phase differentiation of a tri-phase polymer composite using energy-filtering transmission electron microscopy
    Varlot, K
    Martin, JM
    Quet, C
    POLYMER, 2000, 41 (12) : 4599 - 4605
  • [48] C to BN conversion in multi-walled nanotubes as revealed by energy-filtering transmission electron microscopy
    Bando, Y
    Golberg, D
    Mitome, M
    Kurashima, K
    Sato, T
    CHEMICAL PHYSICS LETTERS, 2001, 346 (1-2) : 29 - 34
  • [49] Energy-filtered transmission electron microscopy (EFTEM) of semiconductor devices
    Subramanian, Sam
    Clark, Gary
    Ly, Khiem
    Chrastecky, Tony
    Electronic Device Failure Analysis, 2010, 13 (01): : 20 - 28
  • [50] Quantitative Li Mapping in Al alloys by Sub-eV Resolution Energy-Filtering Transmission Electron Microscopy (EFTEM) in the Aberration-Corrected, Monochromated TEAM0.5 Instrument
    Rossell, M. D.
    Watanabe, M.
    Erni, R.
    Radmilovic, V.
    Dahmen, U.
    MICROSCOPY AND MICROANALYSIS, 2009, 15 : 430 - 431