Indoor and outdoor air quality: A university cafeteria as a case study

被引:30
|
作者
Alves, Celia A. [1 ]
Vicente, Estela D. [1 ]
Evtyugina, Margarita [1 ]
Vicente, Ana M. [1 ]
Nunes, Teresa [1 ]
Lucarelli, Franco [2 ,3 ]
Calzolai, Giulia [2 ,3 ]
Nava, Silvia [2 ,3 ]
Calvo, Ana, I [4 ]
del Blanco Alegre, Carlos [4 ]
Oduber, Fernanda [4 ]
Castro, Amaya [4 ]
Fraile, Roberto [4 ]
机构
[1] Univ Aveiro, Ctr Environm & Marine Studies, Dept Environm, P-3810193 Aveiro, Portugal
[2] Univ Firenze, Dept Phys & Astron, I-50019 Sesto Fiorentino, Italy
[3] INFN Firenze, I-50019 Sesto Fiorentino, Italy
[4] IMARENAB Univ Leon, Dept Phys, Leon 24071, Spain
关键词
Cafeteria; Indoor air quality; PM10; Metals; Organic compounds; Sources; PARTICULATE ORGANIC-MATTER; RESPIRATORY HEALTH; PERSONAL EXPOSURE; EMISSIONS; RESTAURANTS; COOKING; POLLUTION; METALS; PM2.5; BTEX;
D O I
10.1016/j.apr.2019.12.002
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A short but exhaustive air sampling campaign was conducted in a university cafeteria, an occupational environmental not yet studied. Carbonyls and volatile organic compounds were collected by passive diffusion samplers. Temperature, relative humidity, CO2, CO and particulate matter were continuously monitored indoors and outdoors. Simultaneous PM10 sampling with high and low volume instruments, equipped with quartz and Teflon fillers, respectively, was performed during working hours and at night. The quartz filters were analysed for their carbonaceous content by a thermo-optical technique and organic constituents by GC-MS. Water-soluble ions and elements were analysed in the Teflon filters by ion chromatography and PIXE, respectively. Low air change rates (0.31-1.5 h(-1)) and infiltration factors of 0.14, for both PM2.5 and PM10, indicate poor ventilation conditions. Concentrations of both gaseous pollutants and particulate matter were much higher in the cafeteria than outdoors, showing strong variations throughout the day depending on occupancy and activities. The average concentration of indoor-generated PM10 was estimated to be 32 mu g m(-3). Organic compounds in PM10, included alkanes, PAHs, saccharides, phenolics, alcohols, acids, alkyl esters, triterpenoids, sterols, among others. The complex particle composition reveals the multiplicity of sources, formation reactions and removal processes, not yet fully known, and suggests the contribution from dust resuspension, abrasion and off-gassing of building materials, cooking emissions, tobacco smoke, and several consumer products. Many compounds are in the list of ingredients of personal care products, pesticides, plasticisers, flame retardants and psychoactive drugs. The inhalation cancer risks of metals and PAHs were found to be negligible.
引用
收藏
页码:531 / 544
页数:14
相关论文
共 50 条
  • [41] Numerical Study of Indoor Air Quality in a University Professor's Office
    Efren Ovando-Chacon, Guillermo
    Luz Ovando-Chacon, Sandy
    Rodriguez-Leon, Abelardo
    Diaz-Gonzalez, Mario
    [J]. SUSTAINABILITY, 2023, 15 (05)
  • [42] Use of a state space model to study the effect of outdoor air quality on indoor air in fairbanks Alaska
    Marsik, Tom
    Johnson, Ron
    [J]. INDOOR AND BUILT ENVIRONMENT, 2007, 16 (06) : 538 - 547
  • [43] Assessment of indoor air quality in university classrooms
    Kraus, Michal
    Novakova, Petra
    [J]. 10TH INTERNATIONAL SCIENTIFIC CONFERENCE BUILDING DEFECTS (BUILDING DEFECTS 2018), 2019, 279
  • [44] Microbiological quality of indoor air in university rooms
    Stryjakowska-Sekulska, M.
    Piotraszewska-Pajak, A.
    Szyszka, A.
    Nowicki, M.
    Filipiak, M.
    [J]. POLISH JOURNAL OF ENVIRONMENTAL STUDIES, 2007, 16 (04): : 623 - 632
  • [45] INVESTIGATION OF INDOOR AIR QUALITY PROBLEMS IN OFFICES BY A QUESTIONNAIRE: A CASE STUDY OF OFFICES AT MAHASARAKHAM UNIVERSITY, THAILAND
    Ongwandee, Maneerat
    Dungkokkruad, Namphung
    [J]. ANNALS OF DAAAM FOR 2009 & PROCEEDINGS OF THE 20TH INTERNATIONAL DAAAM SYMPOSIUM, 2009, 20 : 441 - 442
  • [46] Investigation of indoor and outdoor air quality of the classrooms at a school in Serbia
    Jovanovic, Marina
    Vucicevic, Biljana
    Turanjanin, Valentina
    Zivkovic, Marija
    Spasojevic, Vuk
    [J]. ENERGY, 2014, 77 : 42 - 48
  • [47] THE EFFECTS OF INDOOR AND OUTDOOR AIR QUALITY ON RESPIRATORY PARAMETERS IN CANAKKALE
    Mirici, Arzu
    Mentese, Sibel
    Bakar, Coskun
    Otkun, Muserref
    Cevizci, Sibel
    Turan, Onur
    [J]. RESPIROLOGY, 2015, 20 : 77 - 77
  • [48] ASSESSMENT OF AIR QUALITY WITH INDOOR AND OUTDOOR CONDITIONS IN WUHAN, CHINA
    Ye, Xiaojiang
    Chen, Huanxin
    Zhou, Zhaoxia
    Li, Duanyong
    Hou, Zhijian
    Lu, Liangyan
    Zhou, Wei
    Qing, E.
    [J]. FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 937 - 943
  • [49] INDOOR-OUTDOOR AIR-QUALITY RELATIONSHIPS - DISCUSSION
    HOWLETT, CT
    [J]. JOURNAL OF THE AIR POLLUTION CONTROL ASSOCIATION, 1982, 32 (09): : 913 - 916
  • [50] Correlation of indoor-outdoor air quality in urban areas
    El-Hougeiri, N
    El Fadel, M
    [J]. INDOOR AND BUILT ENVIRONMENT, 2004, 13 (06) : 421 - 431