Rapid atrial pacing does not decrease the atrial defibrillation threshold

被引:1
|
作者
Frykman, V [1 ]
Darpö, B
Ayers, GM
Bergfeldt, L
Linde, C
Rosenqvist, M
机构
[1] Karolinska Hosp, Dept Cardiol, S-17176 Stockholm, Sweden
[2] MPM Capital LP, San Francisco, CA USA
[3] Soder Sjukhuset, Dept Cardiol, Stockholm, Sweden
来源
关键词
atrial fibrillation; internal defibrillation; cardioversion; defibrillation threshold;
D O I
10.1046/j.1460-9592.2003.t01-1-00211.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of the study was to evaluate the effect of preshock atrial pacing on the atrial defibrillation threshold (DFT) during internal cardioversion of AF. The implantable atrial defibrillator has been added to the therapeutic options for patients with recurrent episodes of persistent AE Although the device is efficient in restoring sinus rhythm, patient discomfort is a limitation. Methods that lower the ADFT are needed. Eleven patients with AF underwent internal cardioversion. In a randomized, crossover design, ADFT testing was performed, applying a step-up protocol starting at 100 V Rapid atrial pacing was performed with a right atrial catheter for 20 seconds at 90% of the average cycle length of the fibrillatory waves and was immediately followed by a biphasic defibrillation shock. At each energy level, pacing + shock was compared to shock only, until the level at which sinus rhythm was restored by both modes. The step-up protocol was thereafter repeated using the inverse sequence of the two modes. A total of 19 ADFTs were obtained. For 10 the ADFT was lower with pacing + shock, in 4 equal and in 5 higher, than with shock only. The ADFT (mean +/- SD) with pacing + shock was 260 +/- 84 V (3.4 +/- 2.9 J) and did not differ from shock only: 268 +/- 85 V (3.8 +/- 3.0 J) (P > 0.05). The coefficient of variation and the coefficient of reproducibility for pacing + shock was 16% and 60 V, respectively, and for shock only 17% and 61 V Rapid atrial pacing did not influence the internal ADFT in AE The randomized, crossover protocol used was reproducible between different modes, and seems useful when testing the impact of different interventions on the ADFT.
引用
收藏
页码:1461 / 1466
页数:6
相关论文
共 50 条
  • [21] Induction of atrial fibrillation in mice by rapid transesophageal atrial pacing
    Jan Wilko Schrickel
    Helga Bielik
    Alexander Yang
    Rainer Schimpf
    Nikolay Shlevkov
    Dietmar Burkhardt
    Rainer Meyer
    Christian Grohé
    Klaus Fink
    Klaus Tiemann
    Berndt Lüderitz
    Thorsten Lewalter
    Basic Research in Cardiology, 2002, 97 : 452 - 460
  • [22] Induction of atrial fibrillation in mice by rapid transesophageal atrial pacing
    Schrickel, JW
    Bielik, H
    Yang, A
    Schimpf, R
    Shlevkov, N
    Burkhardt, D
    Meyer, R
    Grohé, C
    Fink, K
    Tiemann, K
    Lüderitz, B
    Lewalter, T
    BASIC RESEARCH IN CARDIOLOGY, 2002, 97 (06) : 452 - 460
  • [23] FAILURE OF RAPID ATRIAL-PACING IN CONVERSION OF ATRIAL FLUTTER
    ROSEN, KM
    SINNO, MZ
    RAHIMTOOLA, SH
    GUNNAR, RM
    AMERICAN JOURNAL OF CARDIOLOGY, 1972, 29 (04): : 524 - +
  • [24] RAPID ATRIAL-PACING IN CONVERSION OF ATRIAL FLUTTER - REPLY
    ROSEN, KM
    AMERICAN JOURNAL OF CARDIOLOGY, 1973, 31 (02): : 287 - 288
  • [25] NONINVASIVE RAPID ATRIAL-PACING FOR ATRIAL TACHYCARDIA TERMINATION
    WILKOFF, BL
    COLLINS, J
    SCHAAL, SF
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1986, 9 (02): : 304 - 304
  • [26] Rapid atrial pacing and gene expression
    不详
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2000, 11 (07) : 826 - 826
  • [27] Circadian pattern of atrial pacing threshold in the young
    Silvetti, Massimo S.
    De Santis, Antonella
    Marcora, Simona
    De Santo, Tiziana
    Grovale, Nicoletta
    Drago, Fabrizio
    EUROPACE, 2008, 10 (02): : 147 - 150
  • [28] Reduction of atrial defibrillation threshold with an interatrial septal electrode
    Zheng, XS
    Benser, ME
    Walcott, GP
    Girouard, SD
    Rollins, DL
    Smith, WM
    Ideker, RE
    CIRCULATION, 2000, 102 (21) : 2659 - 2664
  • [29] Atrial signal analysis and defibrillation threshold assessment in chronic persistent and reinduced atrial fibrillation
    Boriani, G
    Bartolini, P
    Biffi, M
    Calcagnini, G
    Camanini, C
    Corazza, I
    Zannoli, R
    Barbaro, V
    Branzi, A
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2002, 13 (05) : 449 - 454
  • [30] Defibrillation efficacy for spontaneous atrial fibrillation: Relationship of shock strength to defibrillation threshold
    Swerdlow, CD
    Bailin, SJ
    Warman, EN
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 151A - 152A