Rapid atrial pacing does not decrease the atrial defibrillation threshold

被引:1
|
作者
Frykman, V [1 ]
Darpö, B
Ayers, GM
Bergfeldt, L
Linde, C
Rosenqvist, M
机构
[1] Karolinska Hosp, Dept Cardiol, S-17176 Stockholm, Sweden
[2] MPM Capital LP, San Francisco, CA USA
[3] Soder Sjukhuset, Dept Cardiol, Stockholm, Sweden
来源
关键词
atrial fibrillation; internal defibrillation; cardioversion; defibrillation threshold;
D O I
10.1046/j.1460-9592.2003.t01-1-00211.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of the study was to evaluate the effect of preshock atrial pacing on the atrial defibrillation threshold (DFT) during internal cardioversion of AF. The implantable atrial defibrillator has been added to the therapeutic options for patients with recurrent episodes of persistent AE Although the device is efficient in restoring sinus rhythm, patient discomfort is a limitation. Methods that lower the ADFT are needed. Eleven patients with AF underwent internal cardioversion. In a randomized, crossover design, ADFT testing was performed, applying a step-up protocol starting at 100 V Rapid atrial pacing was performed with a right atrial catheter for 20 seconds at 90% of the average cycle length of the fibrillatory waves and was immediately followed by a biphasic defibrillation shock. At each energy level, pacing + shock was compared to shock only, until the level at which sinus rhythm was restored by both modes. The step-up protocol was thereafter repeated using the inverse sequence of the two modes. A total of 19 ADFTs were obtained. For 10 the ADFT was lower with pacing + shock, in 4 equal and in 5 higher, than with shock only. The ADFT (mean +/- SD) with pacing + shock was 260 +/- 84 V (3.4 +/- 2.9 J) and did not differ from shock only: 268 +/- 85 V (3.8 +/- 3.0 J) (P > 0.05). The coefficient of variation and the coefficient of reproducibility for pacing + shock was 16% and 60 V, respectively, and for shock only 17% and 61 V Rapid atrial pacing did not influence the internal ADFT in AE The randomized, crossover protocol used was reproducible between different modes, and seems useful when testing the impact of different interventions on the ADFT.
引用
收藏
页码:1461 / 1466
页数:6
相关论文
共 50 条
  • [1] Capture of atrial fibrillation reduces the atrial defibrillation threshold
    Villani, GQ
    Nollo, G
    Ravelli, F
    Piepoli, M
    Capucci, A
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2002, 25 (08): : 1159 - 1165
  • [2] Facilitating internal cardioversion of chronic atrial fibrillation with ibutilide - predictors of atrial defibrillation-threshold decrease
    Efremidis, M
    Sideris, A
    Batra, R
    Manolatos, D
    Xidonas, S
    Kardara, D
    Ekonomou, D
    Evangelou, M
    Filippatos, G
    Kardaras, F
    MEDICAL SCIENCE MONITOR, 2004, 10 (06): : CR258 - CR263
  • [3] Can early timed internal atrial defibrillation shocks reduce the atrial defibrillation threshold?
    Fotuhi, PC
    Cooper, RAS
    Sreenan, CM
    Rollins, DL
    Smith, WM
    Ideker, RE
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (08): : 1179 - 1185
  • [4] EFFECTS OF FLECAINIDE ON THE ATRIAL DEFIBRILLATION THRESHOLD
    VANGELDER, IC
    CRIJNS, HJGM
    VANGILST, WH
    DELANGEN, CDJ
    VANWIJK, LM
    LIE, KI
    AMERICAN JOURNAL OF CARDIOLOGY, 1989, 63 (01): : 112 - 114
  • [5] Right atrial septal electrode for reducing the atrial defibrillation threshold
    Zheng, XS
    Benser, ME
    Walcott, GP
    Ideker, RE
    CIRCULATION, 2001, 104 (09) : 1066 - 1070
  • [6] A right atrial septal electrode for reducing the atrial defibrillation threshold
    Zheng, X
    Benser, ME
    Walcott, GP
    Smith, WM
    Ideker, RE
    CIRCULATION, 2000, 102 (18) : 323 - 323
  • [7] A false decrease in the automatically measured atrial pacing threshold when using the automatic pacing threshold adjustment algorithm
    Ishihara, Yu
    Noma, Takahisa
    Takeuchi, Masaki
    Shimokawa, Kohei
    Shiraishi, Yoji
    Inoue, Tomoko
    Ohara, Minako
    Ishikawa, Kaori
    Minamino, Tetsuo
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2023, 46 (11): : 1375 - 1378
  • [8] Effects of left atrial dilatation on the endocardial atrial defibrillation threshold: A study in an ovine model of pacing induced dilated cardiomyopathy
    Power, JM
    Beacom, GA
    Alferness, CA
    Raman, J
    Farish, SJ
    Tonkin, AM
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (08): : 1595 - 1600
  • [9] Effects of postshock atrial pacing on atrial defibrillation outcome in the isolated sheep heart
    Skanes, AC
    Gray, RA
    Zuur, CL
    Jalife, J
    CIRCULATION, 1998, 98 (01) : 64 - 72
  • [10] A comparison of transvenous atrial defibrillation of acute and chronic atrial fibrillation and the effect of intravenous sotalol on human atrial defibrillation threshold
    Lau, CP
    Lok, NS
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (10): : 2442 - 2452