Organ culture storage of pre-prepared corneal donor material for Descemet's membrane endothelial keratoplasty

被引:15
|
作者
Bhogal, Maninder [1 ,2 ]
Matter, Karl [2 ]
Balda, Maria S. [2 ]
Allan, Bruce D. [1 ,2 ]
机构
[1] Moorfields Eye Hosp, Dept Corneal & External Dis, London, England
[2] UCL, Inst Ophthalmol, London, England
基金
英国生物技术与生命科学研究理事会; 英国惠康基金;
关键词
Cornea; Eye (Tissue) Banking; Imaging; Treatment Surgery; Wound healing; GROWTH-FACTORS; PENETRATING KERATOPLASTY; TISSUE-PREPARATION; CELL-DENSITY; IN-VITRO; TRANSPLANTATION; PROLIFERATION; ORGANIZATION; MULTICENTER; FREEZE;
D O I
10.1136/bjophthalmol-2016-308855
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To evaluate the effect of media composition and storage method on pre-prepared Descemet's membrane endothelial keratoplasty (DMEK) grafts. Methods 50 corneas were used. Endothelial wound healing and proliferation in different media were assessed using a standard injury model. DMEK grafts were stored using three methods: peeling with free scroll storage; partial peeling with storage on the stroma and fluid bubble separation with storage on the stroma. Endothelial cell (EC) phenotype and the extent of endothelial overgrowth were examined. Global cell viability was assessed for storage methods that maintained a normal cell phenotype. Results 1mm wounds healed within 4days. Enhanced media did not increase EC proliferation but may have increased EC migration into the wounded area. Grafts that had been trephined showed evidence of EC overgrowth, whereas preservation of a physical barrier in the bubble group prevented this. In grafts stored in enhanced media or reapposed to the stroma after trephination, endothelial migration occurred sooner and cells underwent endothelial-mesenchymal transformation. Ongoing cell loss, with new patterns of cell death, was observed after returning grafts to storage. Grafts stored as free scrolls retained more viable ECs than grafts prepared with the fluid bubble method (74.2 3% vs 60.3 +/- 6%, p=0.04 (n=8). Conclusion Free scroll storage is superior to liquid bubble and partial peeling techniques. Free scrolls only showed overgrowth of ECs after 4days in organ culture, indicating a viable time window for the clinical use of pre-prepared DMEK donor material using this method. Methods for tissue preparation and storage media developed for whole corneas should not be used in pre-prepared DMEK grafts without prior evaluation.
引用
收藏
页码:1576 / 1583
页数:8
相关论文
共 50 条
  • [1] Precut Technique for Descemet's Membrane Endothelial Keratoplasty, Preparation and Storage in Organ Culture
    Bayyoud, T.
    Roeck, D.
    Hofmann, J.
    Bartz-Schmidt, K-U.
    Yoeruek, E.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2012, 229 (06) : 621 - 623
  • [2] Corneal Donor Tissue Preparation for Descemet's Membrane Endothelial Keratoplasty
    Tausif, Hassan N.
    Johnson, Lauren
    Titus, Michael
    Mavin, Kyle
    Chandrasekaran, Navasuja
    Woodward, Maria A.
    Shtein, Roni M.
    Mian, Shahzad I.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2014, (91):
  • [3] Descemet's Membrane Endothelial Keratoplasty with Split Corneal Grafts: The Influence of Tamponade Material and Endothelial Storage Time
    Genc, Selim
    Aygun, Beril Tulu
    Esen, Fehim
    Yildirim, Yusuf
    Agca, Alper
    SEMINARS IN OPHTHALMOLOGY, 2019, 34 (06) : 458 - 463
  • [4] A Comparison of the Corneal Thickness Following Descemet's Stripping Automated Endothelial Keratoplasty and Descemet's Membrane Endothelial Keratoplasty
    Sunouchi, Chihiro
    Hayashi, Takahiko
    Shimizu, Toshiki
    Hara, Yusuke
    Kurita, Junki
    Kobashigawa, Hiroko
    Oyakawa, Itaru
    Ida, Yasutsugu
    Kobayashi, Akira
    Shoji, Jun
    Yamagami, Satoru
    CURRENT EYE RESEARCH, 2023, 48 (08) : 712 - 718
  • [5] Corneal Donor Characteristics and Descemet Membrane Endothelial Keratoplasty Success: A Scoping Review
    Luke, Weinel
    Tamme, Golding-holbrook
    Yee Chen, Jern
    Richard, Mills
    CORNEA, 2021, 40 (07) : 930 - 935
  • [6] Pneumatic Dissection and Storage of Donor Endothelial Tissue for Descemet's Membrane Endothelial Keratoplasty A Novel Technique
    Busin, Massimo
    Scorcia, Vincenzo
    Patel, Amit K.
    Salvalaio, Gianni
    Ponzin, Diego
    OPHTHALMOLOGY, 2010, 117 (08) : 1517 - 1520
  • [7] Comparison of Pre-Descemet Endothelial Keratoplasty and Descemet Membrane Endothelial Keratoplasty in Endothelial Decompensation
    Shanmugam, Chandradevi
    Agarwal, Rinky
    Asif, Mohamed Ibrahime
    Bafna, Rahul Kumar
    Maharana, Prafulla Kumar
    Agarwal, Tushar
    Sinha, Rajesh
    Titiyal, Jeewan Singh
    Sharma, Namrata
    CORNEA, 2023, 42 (03) : 292 - 297
  • [8] Descemet's membrane endothelial keratoplasty (DMEK) versus Descemet's stripping automated endothelial keratoplasty (DSAEK) for corneal endothelial failure (Review)
    Stuart, Alastair J.
    Romano, Vito
    Virgili, Gianni
    Shortt, Alex J.
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2018, (06):
  • [9] Corneal densitometry patterns in Descemet membrane endothelial keratoplasty and Descemet stripping automated keratoplasty
    Jorge Peraza-Nieves
    José-María Sánchez-González
    Carlos Rocha-de-Lossada
    Rahul Rachwani-Anil
    Miriam Sánchez-Valera
    Davide Borroni
    Josep Torras-Sanvicens
    International Ophthalmology, 2023, 43 : 4409 - 4417
  • [10] Corneal densitometry patterns in Descemet membrane endothelial keratoplasty and Descemet stripping automated keratoplasty
    Peraza-Nieves, Jorge
    Sanchez-Gonzalez, Jose-Maria
    Rocha-de-Lossada, Carlos
    Rachwani-Anil, Rahul
    Sanchez-Valera, Miriam
    Borroni, Davide
    Torras-Sanvicens, Josep
    INTERNATIONAL OPHTHALMOLOGY, 2023, 43 (12) : 4409 - 4417