Synthetic Graft for Reconstruction of Middle Hepatic Vein Tributaries in Living-Donor Liver Transplant

被引:8
|
作者
Kamel, Refaat [1 ]
Hatata, Yasser [2 ]
Hosny, Karim [3 ]
Amer, Khaled [4 ]
Taha, Mohamed [5 ]
机构
[1] Ein Shams Univ, Dept Surg, Cairo, Egypt
[2] Fayoum Univ, Dept Surg, Al Fayyum, Egypt
[3] Cairo Univ, Dept Surg, Cairo, Egypt
[4] Mil Med Acad, Dept Surg, Cairo, Egypt
[5] Liver Inst Menoufia, Dept Surg, Menoufia, Egypt
关键词
Segment V; Segment VIII; Expanded polytetrafluoroethylene; Venous congestion; Venous outflow; ANTERIOR SECTOR; DRAINAGE; RECIPIENT; CONGESTION; EFFICACY;
D O I
10.6002/ect.mesot2014.P159
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
Objectives: In middle hepatic vein dominant livers, the anterior segment of the right lobe of the liver (segments V and VIII) drains mainly into the middle hepatic vein. In these donors, when right lobe grafts are procured without the middle hepatic vein, the graft may harbor large segment V and/or VIII veins that need reconstruction to avoid graft congestion and subsequent graft dysfunction. Draining these middle hepatic vein tributaries using autologous or cryopreserved vessels is a solution, despite the possible difficulties of their preparation. However, these vessels are not always available. Our objective was to evaluate the effectiveness and safety of using a synthetic vascular graft. Materials and Methods: Between January 2012 and October 2013, eighteen adult recipients underwent living-donor liver transplant using right lobe grafts without the middle hepatic vein at Dar Al Fouad Hospital, 6th of October City, Egypt. All grafts had a large tributary of the middle hepatic vein. Eight-mm ringed expanded polytetrafluoroethylene vascular grafts were used to drain 15 segment V vein tributaries and 3 segment VIII vein tributaries directly to the inferior vena cava. Follow-up was done using duplex ultrasound to evaluate the patency of the vascular graft and the liver congestion and the liver function tests including liver enzymes. Results: Intraoperative Duplex ultrasound confirmed patency and absent segmental congestion in all 18 recipients. The vascular graft patency was 17/18 at 1 week (94.4%) and 15/18 at 1 month (833%). No recipients developed graft infection at 1 month. Conclusions: Synthetic vascular expanded polytetrafluoroethylene grafts could be used effectively and safely in middle hepatic vein tributary reconstruction to overcome the unavailability of autologous or cryopreserved vessel grafts or just to avoid the additional burden of recovering autologous grafts thus simplifying the procedure.
引用
收藏
页码:318 / 322
页数:5
相关论文
共 50 条
  • [21] Autologous Hepatic Vein Graft for Hepatic Vein Reconstruction in Living Donor Liver Transplantation
    Kato, Yutaro
    Tokoro, Takamasa
    Tanahashi, Yoshinao
    Tsuji, Sho-ichiro
    Kagawa, Tadashi
    Sugioka, Atsushi
    TRANSPLANTATION, 2016, 100 : S185 - S185
  • [22] Modified Hepatic Vein Reconstruction Using Recipient Hepatic Vein Graft To Extend Middle Hepatic Vein in Living Donor Liver Transplantation
    Li, Xiangcheng
    Wang, Xuehao
    Zhang, Feng
    Liu, Cunming
    Cheng, Feng
    LIVER TRANSPLANTATION, 2010, 16 (06) : S136 - S137
  • [23] Effectiveness of anatomic reconstruction of the middle hepatic vein in right lobe graft living donor liver transplantation using natural portal vein graft and synthetic graft
    Ibrahim, Mahmoud M. E.
    Abdo, Mostafa
    Abdelaal, Amr
    Rayan, Mahmoud T.
    EGYPTIAN JOURNAL OF SURGERY, 2024, 43 (03): : 1029 - 1041
  • [24] Usability of Cryopreserved Aortic Allografts for Middle Hepatic Vein Reconstruction During Living-Donor Liver Transplantation
    Kim, Seok-Hwan
    Hwang, Shin
    Ha, Tae-Yong
    Song, Gi-Won
    Jung, Dong-Hwan
    Ahn, Chul-Soo
    Moon, Deok-Bog
    Kim, Ki-Hun
    Park, Gil-Chun
    Lee, Sung-Gyu
    JOURNAL OF GASTROINTESTINAL SURGERY, 2016, 20 (05) : 1049 - 1055
  • [25] Outflow Reconstruction in Right Lobe Living Donor Liver Transplant: Middle Hepatic Vein Reconstruction Versus Separate Tributaries to Inferior Vena Cava Anastomosis
    Taha, Ahmed M., I
    Abdalla, Ahmed M.
    Hassan, Ramy A.
    Elkhateb, Abdelmoneam, I
    Ali, Ahmed M.
    EXPERIMENTAL AND CLINICAL TRANSPLANTATION, 2023, 21 (03) : 245 - 250
  • [26] Migration of the Dacron Interposition Graft for Middle Hepatic Vein Reconstruction in Living Donor Liver Transplantation
    You, Youngkyoung
    Han, JaeHyun
    Choi, HoJoong
    Na, GunHyung
    Lee, SooHo
    Yoon, YoungChul
    Lee, SangKuon
    Rheu, DongDo
    Park, JungHyun
    Kim, DongGoo
    Kim, YouMi
    TRANSPLANTATION, 2018, 102 : S507 - S507
  • [27] PARIETAL PERITONEUM AS A NOVEL SUBSTITUTE FOR MIDDLE HEPATIC VEIN RECONSTRUCTION DURING LIVING-DONOR LIVER TRANSPLANTATION
    Hong, Suk Kyun
    Yi, Nam-Joon
    Cho, Jae-Hyung
    Lee, Jeong-Moo
    Hong, Kwangpyo
    Han, Eui Soo
    Lee, Kwang-Woong
    Suh, Kyung-Suk
    TRANSPLANTATION, 2020, 104 (09) : S496 - S497
  • [28] Parietal peritoneum as a novel substitute for middle hepatic vein reconstruction during living-donor liver transplantation
    Hong, S. K.
    Yi, N. -J.
    Cho, J. -H.
    Lee, J. -M.
    Hong, K.
    Han, E. S.
    Lee, K. -W.
    Suh, K. -S.
    TRANSPLANTATION, 2021, 105 (08) : 102 - 102
  • [29] Usability of Cryopreserved Aortic Allografts for Middle Hepatic Vein Reconstruction During Living-Donor Liver Transplantation
    Seok-Hwan Kim
    Shin Hwang
    Tae-Yong Ha
    Gi-Won Song
    Dong-Hwan Jung
    Chul-Soo Ahn
    Deok-Bog Moon
    Ki-Hun Kim
    Gil-Chun Park
    Sung-Gyu Lee
    Journal of Gastrointestinal Surgery, 2016, 20 : 1049 - 1055
  • [30] Three-dimensional volumetric analysis for reconstruction of middle hepatic vein tributaries in living donor liver transplantation
    Jin, MB
    Onodera, Y
    Furukawa, H
    Todo, S
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2005, 200 (03) : 468 - 469