Radiation therapy of breast carcinoma: Confirmation of prescription dose using diodes

被引:12
|
作者
Yaparpalvi, R [1 ]
Fontenla, DP [1 ]
Yu, L [1 ]
Lai, PP [1 ]
Vikram, B [1 ]
机构
[1] UNIV HOSP,ALBERT EINSTEIN COLL MED,MONTEFIORE MED CTR,DEPT RADIAT ONCOL,BRONX,NY
关键词
in vivo dosimetry; radiation therapy; carcinoma of the breast; diodes; scatter dose; contralateral breast dose;
D O I
10.1016/S0360-3016(96)85027-9
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To quantitate the dose delivered during tangential breast radiation therapy and measure the scatter dose to the contralateral breast for three different breast setup techniques, Methods and Materials: A commercial semiconductor diode system is used for dose measurements, The diode characteristics were studied by comparing the diode response against a standard ionization chamber response in a reference configuration. In vivo dose measurements on 11 patients undergoing tangential breast radiation therapy with 6 MV photons were performed, Medial and lateral held entrance and exit doses were measured and compared with the expected values from the treatment planning system, Scatter doses to the contralateral breast for three breast setup techniques were measured and documented as a function of distance from the held edge and various beam modifiers commonly used in breast radiation therapy, Results: The diodes used in this study exhibited excellent linearity, dose reproducibility, and minimal anisotropy, The in-phantom measurements resulted in dose accuracy within +/- 1.5%, Dose measurements on patients resulted in standard deviations of 1.2 and 2.3% for the medial entrance and exit doses and 1.7 and 2.2% for the lateral entrance and exit doses, respectively, In patients, the scatter doses to the opposite breast at a 5 cm perpendicular distance from the medial field edge resulted in cumulative scatter doses of 2.47 to 5.30 Gy from the tangential fields and an additional 0.50 Gy from the supraclavicular or axillary held, if included, Conclusion: Quantitative verification of the prescribed daily dose is important in breast radiation therapy to ensure precision in patient setup and accuracy in dose delivery, Diodes provide a convenient way of realtime patient dose verification and are easy to use by the therapists.
引用
收藏
页码:173 / 183
页数:11
相关论文
共 50 条
  • [1] Radiation therapy of breast carcinoma: Confirmation of prescription dose
    Yaparpalvi, MSR
    Fontenla, DP
    Yu, L
    Lai, P
    EUROPEAN JOURNAL OF CANCER, 1995, 31A : 194 - 194
  • [2] MASSIVE DOSE TECHNIQUE IN RADIATION THERAPY OF INOPERABLE CARCINOMA OF BREAST
    ATKINS, HL
    AMERICAN JOURNAL OF ROENTGENOLOGY RADIUM THERAPY AND NUCLEAR MEDICINE, 1964, 91 (01): : 80 - &
  • [3] DOSE TO THE OPPOSITE BREAST AS A RESULT OF PRIMARY RADIATION-THERAPY FOR CARCINOMA OF THE BREAST
    SVENSSON, GK
    KASE, KR
    CHIN, LM
    HARRIS, JR
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1981, 7 (09): : 1209 - 1209
  • [4] Towards A Personalized Radiation Therapy Dose-Prescription in Locally Advanced Nasopharyngeal Carcinoma
    Alsafadi, N.
    Khan, M.
    Barakati, Y.
    Saeedi, F.
    Jaber, S.
    Ismail, E. N.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 100 (05): : 1346 - 1347
  • [5] Patterns of dose variability in radiation prescription of breast cancer
    Das, IJ
    Cheng, CW
    Fein, DA
    Fowble, B
    RADIOTHERAPY AND ONCOLOGY, 1997, 44 (01) : 83 - 89
  • [6] Radiation therapy of carcinoma of the breast
    Peters, MV
    CANADIAN MEDICAL ASSOCIATION JOURNAL, 1944, 51 : 335 - 343
  • [7] Radiation therapy in breast carcinoma
    Dunst, Juergen
    BREAST CARE, 2008, 3 (06) : 439 - 443
  • [8] Radiation therapy in carcinoma of the breast
    Bouchard, J
    CANADIAN MEDICAL ASSOCIATION JOURNAL, 1943, 49 : 382 - 387
  • [9] Verification of absorbed dose using diodes in cobalt-60 radiation therapy
    Muhammad Asghar Gadhi
    Shahab Fatmi
    Gul M. Chughtai
    Muhammad Arshad
    Muhammad Shakil
    Uzma Mahmood Rahmani
    Malik Younas Imran
    Saeed Ahmad Buzdar
    Australasian Physical & Engineering Sciences in Medicine, 2016, 39 : 211 - 219
  • [10] Verification of absorbed dose using diodes in cobalt-60 radiation therapy
    Gadhi, Muhammad Asghar
    Fatmi, Shahab
    Chughtai, Gul M.
    Arshad, Muhammad
    Shakil, Muhammad
    Rahmani, Uzma Mahmood
    Imran, Malik Younas
    Buzdar, Saeed Ahmad
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2016, 39 (01) : 211 - 219