Fast speed MWIR imager for uncooled focal plane array - art. no. 672222

被引:0
|
作者
Lin, Liu [1 ]
机构
[1] Soochow Univ, Key Lab Opt Technol, Suzhou 215006, Peoples R China
关键词
optical design; fast speed; infrared optical system; uncooled focal plane array;
D O I
10.1117/12.783115
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Recent advances of uncooled detector technology especially the development of uncooled micro-bolometer array hold promise for us to develop low-cost and compact MWIR earth observation imager. For comparative lower radiometric performance of uncooled focal plane array, fast speed optical system operating in large spectral bands is compatible. In addition, in order to exhibit advantages over imagers based on cooled detector technology, the optical system should be as compact as possible which means fewer elements, smaller size and light weight. In this article, a high speed optical design meeting these requirement is provided with 100mm focal length, F/1 F number,+/- 2.5 degrees field of view woking in 3-5um wave band. The fast speed MWIR imager has properties mentioned as follows: First, the optical system utilizes a hybrid system including refractive and diffractive elements. Second, the optical system realizes athermalization in simple passive way through distributing power among the refractive elements. It can work under typical temperature scope from -20 degrees C to 60 degrees C for typical space application. Third, Because of high speed aperture, the design makes use of aspheric surface to correct spherical aberration and spherochromatism Finally, we use Ge and Si material. instead of expensive ZnS material.
引用
收藏
页码:72222 / 72222
页数:6
相关论文
共 50 条
  • [41] Infrared camera based on 320 X 240 uncooled focal plane array
    Li, YW
    Yi, XJ
    He, ZX
    Luo, Y
    [J]. MULTISPECTRAL AND HYPERSPECTRAL IMAGE ACQUISITION AND PROCESSING, 2001, 4548 : 297 - 301
  • [42] Optimal design of optomechanical uncooled infrared focal plane array with integrated metalens
    Luo, Zhendong
    Hou, Huwang
    Zhang, Yiyuan
    Li, Wenlan
    Zhang, Peng
    Zhao, Yang
    [J]. PHYSICA SCRIPTA, 2024, 99 (01)
  • [43] Design of the low noise uncooled infrared focal plane array driver circuit
    Zhang, Pei
    Zhu, Hong-Bin
    Lv, Jian
    Jiang, Ya-Dong
    [J]. Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2010, 39 (05): : 806 - 810
  • [44] Design and fabrication of a high sensitivity focal plane array for uncooled IR imaging
    Yu, Xiaomei
    Yi, Yuliang
    Ma, Shenglin
    Liu, Ming
    Liu, Xiaohua
    Dong, Liquan
    Zhao, Yuejin
    [J]. JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2008, 18 (05)
  • [45] Investigation of uncooled microbolometer focal plane array infrared camera for quantitative thermography
    Zalameda, JN
    Winfree, WP
    [J]. JOURNAL OF NONDESTRUCTIVE EVALUATION, 2005, 24 (01) : 1 - 9
  • [46] A test method of thermal time constant for uncooled infrared focal plane array
    Liu, Ziji
    Zhao, Shengchen
    Zhao, Zhengting
    Li, Yuda
    Zheng, Xing
    Zhang, Lei
    [J]. Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2019, 48 (12):
  • [47] Investigation of Uncooled Microbolometer Focal Plane Array Infrared Camera for Quantitative Thermography
    Joseph N. Zalameda
    William P. Winfree
    [J]. Journal of Nondestructive Evaluation, 2005, 24 : 1 - 9
  • [48] Improved nonlinear method of nonuniformity correction for infrared focal plane arrays - art. no. 678716
    Jiang, Hua
    Li, Qinghui
    [J]. MIPPR 2007: MULTISPECTRAL IMAGE PROCESSING, 2007, 6787 : 78716 - 78716
  • [49] A conceptual midwave infrared remoting sensor based on an uncooled focal plane array
    Liu Lin
    Shen Weimin
    Chen Yuheng
    [J]. 2008 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY: OPTICAL SYSTEMS AND OPTOELECTRONIC INSTRUMENTS, 2009, 7156
  • [50] 320x240 microbolometer focal plane array for uncooled applications
    Radford, W
    Murphy, D
    Ray, M
    Propst, S
    Kennedy, A
    Soch, K
    Coda, R
    Lung, G
    Moody, E
    Gleichman, D
    [J]. PHOTODETECTORS: MATERIALS AND DEVICES, 1996, 2685 : 80 - 90