MRI diffusion tensor imaging scalar values in dogs with intervertebral disc herniation: A comparison between manual and semiautomated region of interest methods

被引:0
|
作者
Shinn, Richard [1 ]
Riffe, Ashley [2 ]
Edwards, Michael [1 ]
Rossmeisl, John [1 ]
机构
[1] Virginia Polytech Inst & State Univ, Virginia Maryland Coll Vet Med, Dept Small Anim Clin Sci, Blacksburg, VA 24061 USA
[2] VCA Alameda East Vet Hosp, Denver, CO USA
关键词
axial diffusivity; fractional anisotropy; mean diffusivity; radial diffusivity; spinal cord toolbox; SPINAL-CORD; CLINICAL-ASSESSMENT;
D O I
10.1111/vru.13126
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Magnetic resonance imaging (MRI) diffusion tensor imaging (DTI) measures have been described as methods for quantifying spinal cord injury and predicting outcome in dogs with intervertebral disc herniation (IVDH); however, studies comparing methods for selecting regions of interest (ROIs) are currently lacking. The aims of this retrospective, methods comparison, observational study were to compare DTI measurements acquired using manual (mROI) versus semiautomated ROI (sROI) methods and to compare DTI measurements with patient outcomes. Magnetic resonance imaging scans that included DTI pulse sequences were retrieved for 65 dogs with confirmed IVDH. Regions of interest were placed at one vertebral length cranial and caudal to the region of spinal cord compression (RSCC) using the mROI and sROI methods. Scalar values based on the mROI and sROI methods were compared. There was a significant difference for all DTI measures (P < 0.0001), where fractional anisotropy was higher (95% confidence interval [CI]: 0.15, 0.19) and mean diffusivity (MD; CI: -0.41, -0.35), axial diffusivity (AD; CI: -0.47, -0.36) and radial diffusivity (RD; CI: -0.36, -0.27) were lower for the mROI than for the sROI. For both the mROI and sROI, MD, AD, and RD were significantly lower (p < 0.05) at the RSCC in paraplegic dogs that did not regain motor function. The findings indicated that DTI methods for quantifying SCI using open source software and ROI were feasible for use in dogs with IVDH; however, values based on sROI methods differed from values based on mROI methods. Some DTI measures based on both the mROI and sROI methods were predictive of poor patient outcome.
引用
收藏
页码:753 / 762
页数:10
相关论文
共 25 条
  • [21] Diffusion Tensor Imaging of Dystrophic Skeletal Muscle: Comparison of Two Segmentation Methods Adapted to Chemical-shift-encoded Water-fat MRI
    Keller, S.
    Wang, Z. J.
    Aigner, A.
    Kim, A. C.
    Golsari, A.
    Kooijman, H.
    Adam, G.
    Yamamura, J.
    CLINICAL NEURORADIOLOGY, 2019, 29 (02) : 231 - 242
  • [22] Exploring the correlation between magnetic resonance diffusion tensor imaging (DTI) parameters and aquaporin expression and biochemical composition content in degenerative intervertebral disc nucleus pulposus tissue: a clinical experimental study
    Chen, Shuang
    Sun, Shenglu
    Wang, Nan
    Fang, Xiaoyang
    Xie, Lin
    Hu, Fei
    Xi, Zhipeng
    BMC MUSCULOSKELETAL DISORDERS, 2025, 26 (01)
  • [23] Comparing Region of Interest versus Voxel-Wise Diffusion Tensor Imaging Analytic Methods in Mild and Moderate Traumatic Brain Injury: A Systematic Review and Meta-Analysis
    Hunter, Liane E.
    Lubin, Naomi
    Glassman, Nancy R.
    Xue, Xiaonan
    Spira, Moshe
    Lipton, Michael L.
    JOURNAL OF NEUROTRAUMA, 2019, 36 (08) : 1222 - 1230
  • [24] ASSESSMENT OF NORMAL VALUES OF FRACTIONAL ANISOTROPY AND MEAN DIFFUSIVITY OF MOBILE LUMBAR SPINE NERVE ROOTS BY DIFFUSION TENSOR MR IMAGING: COMPARISON BETWEEN 1.5 AND 3T
    Lincot, J.
    Laissy, J. P.
    Hess, A.
    Balbi, V.
    Schouman-Claeys, E.
    Cotten, A.
    Dallaudiere, B.
    JBR-BTR, 2015, 98 (02): : 68 - 71
  • [25] Comparison between T2-weighted two-dimensional and three-dimensional fast spin-echo MRI sequences for characterizing thoracolumbar intervertebral disc disease in small-breed dogs
    Lee, Suhyeon
    Hwang, Jeongyeon
    Ko, Jaeeun
    Jeong, Jeongyun
    Eom, Kidong
    Kim, Jaehwan
    VETERINARY RADIOLOGY & ULTRASOUND, 2022, 63 (02) : 216 - 223