Array Calibration and Health/Status Check Using a "Reverse" Transmit/Receive Module

被引:0
|
作者
Champion, Michelle [1 ]
Tomasic, Boris [1 ]
Schmier, Robert [2 ]
Bishop, Diane [3 ]
Radford, Jesse [3 ]
Bharj, Sarjit [4 ]
机构
[1] US Air Force, Res Lab, Sensors Directorate, Wright Patterson AFB, OH 45433 USA
[2] Alpha Omega Electromagnet LLC, Arnold, MD 21012 USA
[3] Custom Mfg & Engn Inc, Pinellas Park, FL 33781 USA
[4] Princeton Microwave Technol Inc, Mercerville, NJ 08619 USA
关键词
phased array; calibration; transmit/receive module;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A method for in situ evaluation of the health and status of individual array elements within a large phased array has been developed and demonstrated at the subarray level. The technique utilizes a special radiating element located in the center of each subarray. This center element is fed with a "reverse" T/R module that operates in the opposite sense of the regular elements in the subarray; that is, for dual-band communications arrays, it transmits at the receive frequency and receives at the transmit frequency of the other elements in the array. A similar technique can also be applied to arrays for radar. By operating in this manner, the "reverse" element can be used to self-test the regular elements in the subarray, without requiring an external RF source. This method allows for detection of element faults and failures so that error correction or repairs can be applied without significant impact to operation
引用
下载
收藏
页码:642 / 648
页数:7
相关论文
共 50 条
  • [41] Using a whole-body 31P birdcage transmit coil and 16-element receive array for human cardiac metabolic imaging at 7T
    Valkovic, Ladislav
    Dragonu, Iulius
    Almujayyaz, Salam
    Batzakis, Alex
    Young, Liam A. J.
    Purvis, Lucian A. B.
    Clarke, William T.
    Wichmann, Tobias
    Lanz, Titus
    Neubauer, Stefan
    Robson, Matthew D.
    Klomp, Dennis W. J.
    Rodgers, Christopher T.
    PLOS ONE, 2017, 12 (10):
  • [42] Proteomic analysis of malignant and benign endometrium according to obesity and insulin resistance status using reverse phase protein array
    Raglan, O.
    Assi, N.
    Nautiyal, J.
    Lu, H.
    Gabra, H.
    Gunter, M. J.
    Kyrgiou, M.
    BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2019, 126 : 81 - 81
  • [43] Sodium-23 MRI of whole spine at 3 Tesla using a 5-channel receive-only phased-array and a whole-body transmit resonator
    Malzacher, Matthias
    Kalayciyan, Raffi
    Konstandin, Simon
    Haneder, Stefan
    Schad, Lothar R.
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2016, 26 (01): : 95 - 100
  • [44] Proteomic analysis of malignant and benign endometrium according to obesity and insulin-resistance status using Reverse Phase Protein Array
    Raglan, Olivia
    Assi, Nada
    Nautiyal, Jaya
    Lu, Haonan
    Gabra, Hani
    Gunter, Marc J.
    Kyrgiou, Maria
    TRANSLATIONAL RESEARCH, 2020, 218 : 57 - 72
  • [45] T2-Weighted Prostate MRI at 7 Tesla Using a Simplified External Transmit-Receive Coil Array: Correlation With Radical Prostatectomy Findings in Two Prostate Cancer Patients
    Rosenkrantz, Andrew B.
    Zhang, Bei
    Ben-Eliezer, Noam
    Le Nobin, Julien
    Melamed, Jonathan
    Deng, Fang-Ming
    Taneja, Samir S.
    Wiggins, Graham C.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 41 (01) : 226 - 232
  • [46] Design and development of a CPW-based 5-bit switched-line phase shifter using inline metal contact MEMS series switches for 17.25 GHz transmit/receive module application
    Dey, Sukomal
    Koul, Shiban K.
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2014, 24 (01)
  • [47] 60-GHz Four-Element Phased-Array Transmit/Receive System-in-Package Using Phase Compensation Techniques in 65-nm Flip-Chip CMOS Process
    Kuo, Jing-Lin
    Lu, Yi-Fong
    Huang, Ting-Yi
    Chang, Yi-Long
    Hsieh, Yi-Keng
    Peng, Pen-Jui
    Chang, I-Chih
    Tsai, Tzung-Chuen
    Kao, Kun-Yao
    Hsiung, Wei-Yuan
    Wang, James
    Hsu, Yungping Alvin
    Lin, Kun-You
    Lu, Hsin-Chia
    Lin, Yi-Cheng
    Lu, Liang-Hung
    Huang, Tian-Wei
    Wu, Ruey-Beei
    Wang, Huei
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2012, 60 (03) : 743 - 756
  • [48] Indirect 1H-[13C] MRS of the human brain at 7 T using a 13C-birdcage coil and eight transmit-receive 1H-dipole antennas with a 32-channel 1H-receive array
    Jacobs, Sarah M.
    Prompers, Jeanine J.
    van Der Kemp, Wybe J. M.
    van Der Velden, Tijl A.
    Gosselink, Mark
    Meliado, Ettore Flavio
    Hoogduin, Hans M.
    Mason, Graeme F.
    de Graaf, Robin A.
    Miller, Corin O.
    Bredael, Gerard M.
    van Der Kolk, Anja G.
    Alborahal, Cezar
    Klomp, Dennis W. J.
    Wiegers, Evita C.
    NMR IN BIOMEDICINE, 2024,
  • [49] In vivo phosphorus magnetic resonance spectroscopic imaging of the whole human liver at 7 T using a phosphorus whole-body transmit coil and 16-channel receive array: Repeatability and effects of principal component analysis-based denoising
    van den Wildenberg, Lieke
    Gursan, Ayhan
    Seelen, Leonard W. F.
    van der Velden, Tijl A.
    Gosselink, Mark W. J. M.
    Froeling, Martijn
    van der Kemp, Wybe J. M.
    Klomp, Dennis W. J.
    Prompers, Jeanine J.
    NMR IN BIOMEDICINE, 2023, 36 (05)
  • [50] Diffusion-weighted MRI precisely predicts telomerase reverse transcriptase promoter mutation status in World Health Organization grade IV gliomas using a residual convolutional neural network
    Hu, Congman
    Fang, Ke
    Du, Quan
    Chen, Jiarui
    Wang, Lin
    Zhang, Jianmin
    Bai, Ruiliang
    Wang, Yongjie
    BRITISH JOURNAL OF RADIOLOGY, 2024,