A Micro-Scale Analytical Method for Determining Glycogen Turnover by NMR and FTMS

被引:1
|
作者
Scott, Timothy L. [1 ,2 ,4 ]
Zhu, Juan [1 ,5 ]
Cassel, Teresa A. [1 ]
Vicente-Munoz, Sara [1 ,6 ]
Lin, Penghui [1 ]
Higashi, Richard M. [2 ,3 ]
Lane, Andrew N. [2 ,3 ]
Fan, Teresa W-M [2 ,3 ]
机构
[1] Univ Kentucky, Ctr Environm & Syst Biochem, Lexington, KY 40506 USA
[2] Univ Kentucky, Markey Canc Ctr, Lexington, KY 40506 USA
[3] Univ Kentucky, Ctr Environm & Syst Biochem, Dept Toxicol & Canc Biol, Lexington, KY 40506 USA
[4] Machaon Diagnost Inc, 2023 Eighth St, Berkeley, CA 94710 USA
[5] Jiangsu Prov Hosp Tradit Chinese Med, Dept Anesthesiol, Nanjing 210029, Peoples R China
[6] Cincinnati Childrens Hosp Med Ctr, NMR Based Metabol Core Facil, Div Pathol & Lab Med, Cincinnati, OH 45229 USA
关键词
glycogen turnover; C-13(6)-glucose; stable isotope resolved metabolomics (SIRM); microwave-assisted hydrolysis; ISOTOPE-RESOLVED METABOLOMICS; LIVER-GLYCOGEN; METABOLISM; GLUCOSE; IDENTIFICATION; PHOSPHORYLASE;
D O I
10.3390/metabo12080760
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Glycogen is a readily deployed intracellular energy storage macromolecule composed of branched chains of glucose anchored to the protein glycogenin. Although glycogen primarily occurs in the liver and muscle, it is found in most tissues, and its metabolism has been shown to be important in cancers and immune cells. Robust analysis of glycogen turnover requires stable isotope tracing plus a reliable means of quantifying total and labeled glycogen derived from precursors such as C-13(6)-glucose. Current methods for analyzing glycogen are time- and sample-consuming, at best semi-quantitative, and unable to measure stable isotope enrichment. Here we describe a microscale method for quantifying both intact and acid-hydrolyzed glycogen by ultra-high-resolution Fourier transform mass spectrometric (UHR-FTMS) and/or NMR analysis in stable isotope resolved metabolomics (SIRM) studies. Polar metabolites, including intact glycogen and their C-13 positional isotopomer distributions, are first measured in crude biological extracts by high resolution NMR, followed by rapid and efficient acid hydrolysis to glucose under N-2 in a focused beam microwave reactor, with subsequent analysis by UHR-FTMS and/or NMR. We optimized the microwave digestion time, temperature, and oxygen purging in terms of recovery versus degradation and found 10 min at 110-115 degrees C to give >90% recovery. The method was applied to track the fate of C-13(6)-glucose in primary human lung BEAS-2B cells, human macrophages, murine liver and patient-derived tumor xenograft (PDTX) in vivo, and the fate of H-2(7)-glucose in ex vivo lung organotypic tissue cultures of a lung cancer patient. We measured the incorporation of C-13(6)-glucose into glycogen and its metabolic intermediates, UDP-Glucose and glucose-1-phosphate, to demonstrate the utility of the method in tracing glycogen turnover in cells and tissues. The method offers a quantitative, sensitive, and convenient means to analyze glycogen turnover in mg amounts of complex biological materials.
引用
收藏
页数:15
相关论文
共 50 条
  • [11] An experimental method for micro-scale uniaxial tension test
    Tang, Zhongbin
    Xu, Fei
    Li, Yulong
    Xu, Wujun
    [J]. Experimental Mechanics in Nano and Biotechnology, Pts 1 and 2, 2006, 326-328 : 233 - 236
  • [12] Antimicrobial Activity of Formylchromones: Detection by a Micro-Scale Method
    Lehtinen, Markku
    Pelttari, Eila
    Elo, Hannu
    [J]. ZEITSCHRIFT FUR NATURFORSCHUNG SECTION C-A JOURNAL OF BIOSCIENCES, 2011, 66 (11-12): : 562 - 570
  • [13] ANALYTICAL SOLUTIONS FOR NONLINEAR FREE VIBRATION OF MICRO-SCALE TIMOSHENKO BEAMS
    Saadatnia, Zia
    Esmailzadeh, Ebrahim
    Younesian, Davood
    [J]. PROCEEDINGS OF THE ASME INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, 2016, VOL 8, 2016,
  • [14] A practical kit for micro-scale application of the ceiling crystallisation method
    Adawy, Alaa
    Corbeek, Wil
    de Ronde, Erik
    van Enckevort, Willem J. P.
    de Grip, Willem J.
    Vlieg, Elias
    [J]. CRYSTENGCOMM, 2015, 17 (13): : 2602 - 2605
  • [15] A Novel Method for Simulating Micro-Scale Water Droplet Movements
    Lin, Zhijie
    Hu, Zhongtian
    Lou, Senyu
    Guo, Lingling
    Chen, Jingjing
    [J]. SEPARATIONS, 2022, 9 (12)
  • [16] Fabrication of micro-scale gratings for moire method with a femtosecond laser
    Yan, Gaosheng
    Zhu, Jianguo
    Huang, Yanlong
    Hao, Wenfen
    Li, Yanjie
    [J]. THEORETICAL AND APPLIED MECHANICS LETTERS, 2016, 6 (04) : 171 - 175
  • [17] Micro-scale temperature measurement method using fluorescence polarization
    Tatsumi, K.
    Hsu, C-H.
    Suzuki, A.
    Nakabe, K.
    [J]. 7TH EUROPEAN THERMAL-SCIENCES CONFERENCE (EUROTHERM2016), 2016, 745
  • [18] IMAGING METHOD OF OOCYTE BY USING A MICRO-SCALE ROTATIONAL FLOW
    Yalikun, Yaxiaer
    Aishan, Yusufu
    Sumiyama, Kenta
    Tanaka, Yo
    [J]. 2017 INTERNATIONAL SYMPOSIUM ON MICRO-NANOMECHATRONICS AND HUMAN SCIENCE (MHS), 2017,
  • [19] Information preservation method for micro-scale flow with temperature variation
    Xue, XB
    Yao, ZH
    He, F
    [J]. ACTA PHYSICA SINICA, 2006, 55 (03) : 1276 - 1282
  • [20] MICRO-SCALE PEPTIDE MAPPING METHOD FOR IDENTIFICATION OF VARIANT PROTEINS
    WATANABE, S
    YOSHIDA, A
    [J]. BIOCHEMICAL GENETICS, 1971, 5 (06) : 541 - &