Fast Monte Carlo based joint iterative reconstruction for simultaneous 99mTc/123I SPECT imaging

被引:33
|
作者
Ouyang, Jinsong [1 ]
El Fakhri, Georges
Moore, Stephen C.
机构
[1] Harvard Univ, Sch Med, Dept Radiol, Boston, MA 02115 USA
[2] Brigham & Womens Hosp, Boston, MA 02115 USA
关键词
dual-radionuclide; brain SPECT; fast Monte Carlo; joint; OSEM; JOSEM; MC-JOSEM;
D O I
10.1118/1.2756601
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Simultaneous (99m)-Tc/(123) 1211 SPECT allows the assessment of two physiological functions under identical conditions. The separation of these radionuclides is difficult, however, because their energies are close. Most energy-window-based scatter correction methods do not fully model either physical factors or patien t- specific activity and attenuation distributions. We have developed a fast Monte Carlo (MC) simulation-based multiple-radionuclide and multiple-energy joint ordered-subset expectation-maximization (JOSEM) iterative reconstruction algorithm, MC-JOSEM. MC-JOSEM simultaneously corrects for scatter and cross talk as well as detector response within the reconstruction algorithm. We evaluated MC-JOSEM for simultaneous brain profusion (Tc-99m-HMPAO) and neurotransmission (I-123-altropane) SPECT. MC simulations of Tc-99m and 1231 studies were generated separately and then combined to mimic simultaneous Tc-99m/ 123, SPECT. All the details of photon transport through the brain, the collimator, and detector, including Compton and coherent scatter, septal penetration, and backscatter from components behind the crystal, were modeled. We reconstructed images from simultaneous dual-radionuclide projections in three ways. First, we reconstructed the photopeak-energy-window projections (with an asymmetric energy window for 1231) using the standard ordered-subsets expectation-maximization algorithm (NSC-OSEM). Second, we used standard OSEM to reconstruct 99'Tc photopeak-energy-window projections, while including an estimate of scatter from a Compton-scatter energy window (SC-OSEM). Third, we jointly reconstructed both 99'Tc and 123, images using projection data associated with two photopeak energy windows and an intermediate-energy window using MC-JOSEM. For 15 iterations of reconstruction, the bias and standard deviation of 99'Tc activity estimates in several brain structures were calculated for NSC-OSEM, SC-OSEM, and MC-JOSEM, using images reconstructed from primary (unscattered) photons as a reference. Similar calculations were performed for 123, images for NSC-OSEM and MC-JOSEM. For 123, images, dopamine binding potential (BP) at equilibrium and its signal-to-noise ratio (SNR) were also calculated. Our results demonstrate that MC-JOSEM performs better than NSC- and SGOSEM for quantitation tasks. After 15 iterations of reconstruction, the relative bias of 99'Tc activity estimates in the thalamus, striata, white matter, and gray matter volumes from MC-JOSEM ranged from -2.4% to 1.2%. while the same estimates for NSGOSEM (SC-OSEM) ranged from 20.8% to 103.6% (7.2% to 41.9%). Similarly, the relative bias of 123 1 activity estimates from 15 iterations of MC-JOSEM in the striata and background ranged from -1.4% to 2.9%, while the same estimates for NSGOSEM ranged from 1.6% to 10.0%. The relative standard deviation of 99'Tc activity estimates from MC-JOSEM ranged from 1. 1% to 4.8% versus 1.2% to 6.7% (1.2% to 5.9%) for NSGOSEM (SC-OSEM). The relative standard deviation of 123 1 activity estimates using MC-JOSEM ranged from 1.1% to 1.9% versus 1.5% to 2.7% for NSC-OSEM. Using the 1231 dopamine BP obtained from the reconstruction produced by primary photons as a reference, the result for MC-JOSEM was 50.5% closer to the reference than that of NSC-OSEM after 15 iterations. The SNR for dopamine BP was 23.6 for MC-JOSEM as compared to 18.3 for NSC-OSEM. (c) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:3263 / 3272
页数:10
相关论文
共 50 条
  • [31] A Crosstalk Compensation for Simultaneous 99mTc/123I/111In Triple-isotope SPECT Imaging by Filtering Technique and Artificial Neural Network
    Chuang, K.
    Yang, M.
    Chiang, C.
    Lin, H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S729 - S730
  • [32] Dual-isotope SPECT brain imaging using 123I and 99mTc for two independent activation tasks.
    Zubal, G
    Nishizawa, S
    Fujibayashi, Y
    Yonekura, Y
    JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 200P - 200P
  • [33] Clinical and [99mTc]TRODAT-1/[123I]IBZM SPECT imaging findings in dopa-responsive dystonia
    Hwang, WJ
    Yao, WJ
    Wey, SP
    Ting, G
    EUROPEAN NEUROLOGY, 2004, 51 (01) : 26 - 29
  • [34] Dual nuclide quantitative imaging with 99mTc/123I using CZT gamma camera
    Laforest, Richard
    Beyder, Dmitry
    Scheve, William
    Silvestros, Delynn
    Shmuel, Natalie
    Kovalski, Gil
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58
  • [35] Cross-talk correction for dual radionuclide brain imaging with 99mTc and 123I
    Erlandsson, K
    Visvikis, D
    Waddington, WA
    Costa, DC
    Jarritt, P
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 1561 - 1565
  • [36] First assessment of simultaneous dual isotope (123I/99mTc) cardiac SPECT on two different CZT cameras: A phantom study
    Blaire, Tanguy
    Bailliez, Alban
    Ben Bouallegue, Faycal
    Bellevre, Dimitri
    Agostini, Denis
    Manrique, Alain
    JOURNAL OF NUCLEAR CARDIOLOGY, 2018, 25 (05) : 1692 - 1704
  • [37] First assessment of simultaneous dual isotope (123I/99mTc) cardiac SPECT on two different CZT cameras: A phantom study
    Tanguy Blaire
    Alban Bailliez
    Fayçal Ben Bouallegue
    Dimitri Bellevre
    Denis Agostini
    Alain Manrique
    Journal of Nuclear Cardiology, 2018, 25 : 1692 - 1704
  • [38] [99mTc]TRODAT-1/[123I]IBZM SPECT studies of the dopaminergic system in Tourette syndrome
    Hwang, Wen-Juh
    Yao, Wei-Jen
    Fu, Ying-Kai
    Yang, An-Shoei
    PSYCHIATRY RESEARCH-NEUROIMAGING, 2008, 162 (02) : 159 - 166
  • [39] Scatter and crosstalk corrections for 99mTc/123I dual-radionuclide imaging using a CZT SPECT system with pinhole collimators
    Fan, Peng
    Hutton, Brian F.
    Holstensson, Maria
    Ljungberg, Michael
    Pretorius, P. Hendrik
    Prasad, Rameshwar
    Ma, Tianyu
    Liu, Yaqiang
    Wang, Shi
    Thorn, Stephanie L.
    Stacy, Mitchel R.
    Sinusas, Albert J.
    Liu, Chi
    MEDICAL PHYSICS, 2015, 42 (12) : 6895 - 6911
  • [40] Image evaluation of different 99mTc/123I ratios for simultaneous dual-isotope myocardial SPECT using D-SPECT cardiac camera
    Shibutani, T.
    Onoguchi, M.
    Yoneyama, H.
    Konishi, T.
    Nakajima, K.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S834 - S834