NUMERICAL INVESTIGATION OF THE PERFORMANCE OF A FORCED DRAFT AIR-COOLED HEAT EXCHANGER

被引:0
|
作者
Engelbrecht, Ruan A. [1 ]
Van der Spuy, Johan [1 ]
Meyer, Chris J. [1 ]
Zapke, Albert [2 ]
机构
[1] Stellenbosch Univ, Dept Mech Engn, Private Bag X1, ZA-7602 Stellenbosch, South Africa
[2] Enexio Management GmbH, Global Head Technol R&D, Dorstener St 18-29, D-44651 Herne, Germany
关键词
FLOW-FIELD; SIMULATION;
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper details the design, validation and verification of. two implicit modelling techniques used to model an Air-Cooled Condenser (ACC) in the computational fluid dynamics (CFD) code environment of OpenFOAM (Open Source Field And Manipulation). The actuator disk model was chosen as the axial flow fan model and the heat exchanger model was implemented as an A-frame, or Delta frame, heat exchanger commonly found on power stations. Both models were validated and verified. A 30 fan ACC was verified against previous literature. The results for all validation and verification procedures showed good agreement with respective data. Three different fan configurations in an ACC were compared at different wind speeds namely the A fan, B2a-fan and a Combined ACC. The study showed small differences between ACCs with regard to fan and thermal performance. However, the B2a-fan ACC consumed 20 % less power than the A-fan ACC and 3-10 % less power than the Combined ACC. This performance increase was most prominently show-cased by the increased heat-to-power ratio with the B2a-fan exhibiting heat-to-power ratios of 110 W/W compared to 96 W/W for the A-fan.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Numerical investigation of fan performance in a forced draft air-cooled steam condenser
    Bredell, JR
    Kröger, DG
    Thiart, GD
    [J]. APPLIED THERMAL ENGINEERING, 2006, 26 (8-9) : 846 - 852
  • [2] Numerical investigation of the effect of inlet flow distortions on forced draught air-cooled heat exchanger performance
    Meyer, CJ
    [J]. APPLIED THERMAL ENGINEERING, 2005, 25 (11-12) : 1634 - 1649
  • [3] Numerical investigation of the effect of fan performance on forced draught air-cooled heat exchanger plenum chamber aerodynamic behaviour
    Meyer, CJ
    Kröger, DG
    [J]. APPLIED THERMAL ENGINEERING, 2004, 24 (2-3) : 359 - 371
  • [4] Investigation of heat exchanger inclination in forced-draught air-cooled heat exchangers
    Kennedy, Ian J.
    Spence, Stephen W. T.
    Spratt, Gordon R.
    Early, Juliana M.
    [J]. APPLIED THERMAL ENGINEERING, 2013, 54 (02) : 413 - 421
  • [5] Air-cooled heat exchanger applied to external rotary kiln wall in forced and natural draft
    Huchet, F.
    Piton, M.
    Del Barrio, A.
    Le Corre, O.
    Cazacliu, B.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2017, 154 : 517 - 525
  • [6] Enhance air-cooled heat exchanger performance
    Shastri, SS
    Karimi, IA
    Rangaiah, GP
    Yap, C
    [J]. HYDROCARBON PROCESSING, 2001, 80 (12): : 49 - +
  • [7] Optimize air-cooled heat exchanger performance
    Agius, N.
    [J]. HYDROCARBON PROCESSING, 2006, 85 (07): : 89 - +
  • [8] Improve Air-Cooled Heat Exchanger Performance
    Boes, Steve
    [J]. CHEMICAL ENGINEERING PROGRESS, 2017, 113 (01) : 39 - 45
  • [9] PROGRAM PREDICTS AIR-COOLED HEAT-EXCHANGER PERFORMANCE
    MILLER, S
    [J]. POWER ENGINEERING, 1990, 94 (12) : 22 - 23
  • [10] EFFECT OF INLET FLOW DISTORTIONS ON FAN PERFORMANCE IN FORCED DRAFT AIR-COOLED HEAT-EXCHANGERS
    SALTA, CA
    KROGER, DG