In vivo thickness dynamics measurement of tear film lipid and aqueous layers with optical coherence tomography and maximum-likelihood estimation

被引:18
|
作者
Huang, Jinxin [1 ]
Hindman, Holly B. [2 ]
Rolland, Jannick P. [3 ]
机构
[1] Univ Rochester, Dept Phys & Astron, Rochester, NY 14627 USA
[2] Univ Rochester, Flaum Eye Inst, Rochester, NY 14642 USA
[3] Univ Rochester, Inst Opt, Rochester, NY 14627 USA
基金
美国国家科学基金会;
关键词
REFRACTIVE-INDEX; PRECORNEAL; INTERFEROMETRY; EPITHELIUM; QUALITY; SURFACE; PHANTOM;
D O I
10.1364/OL.41.001981
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Dry eye disease (DED) is a common ophthalmic condition that is characterized by tear film instability and leads to ocular surface discomfort and visual disturbance. Advancements in the understanding and management of this condition have been limited by our ability to study the tear film secondary to its thin structure and dynamic nature. Here, we report a technique to simultaneously estimate the thickness of both the lipid and aqueous layers of the tear film in vivo using optical coherence tomography and maximum-likelihood estimation. After a blink, the lipid layer was rapidly thickened at an average rate of 10 nm/s over the first 2.5 s before stabilizing, whereas the aqueous layer continued thinning at an average rate of 0.29 mu m/s of the 10 s blink cycle. Further development of this tear film imaging technique may allow for the elucidation of events that trigger tear film instability in DED. (C) 2016 Optical Society of America
引用
收藏
页码:1981 / 1984
页数:4
相关论文
共 50 条
  • [1] IN VIVO MEASUREMENT OF TEAR FILM DYNAMICS WITH OPTICAL COHERENCE TOMOGRAPHY AND MAXIMUM-LIKELIHOOD ESTIMATION
    Rolland-Thompson, Jannick P.
    Huang, Jinxin
    Hindman, Holly Butler
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [2] TEAR FILM THICKNESS ESTIMATION USING OPTICAL COHERENCE TOMOGRAPHY AND MAXIMUM-LIKELIHOOD ESTIMATION
    Huang, Jinxin
    Tankam, Patrice
    Aquavella, James V.
    Hindman, Holly Butler
    Clarkson, Eric
    Kupinski, Matthew
    Rolland-Thompson, Jannick
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [3] Maximum-likelihood estimation in Optical Coherence Tomography in the context of the tear film dynamics
    Huang, Jinxin
    Clarkson, Eric
    Kupinski, Matthew
    Lee, Kye-sung
    Maki, Kara L.
    Ross, David S.
    Aquavella, James V.
    Rolland, Jannick P.
    BIOMEDICAL OPTICS EXPRESS, 2013, 4 (10): : 1806 - 1816
  • [4] Phantom study of tear film dynamics with optical coherence tomography and maximum-likelihood estimation
    Huang, Jinxin
    Lee, Kye-sung
    Clarkson, Eric
    Kupinski, Matthew
    Maki, Kara L.
    Ross, David S.
    Aquavella, James V.
    Rolland, Jannick P.
    OPTICS LETTERS, 2013, 38 (10) : 1721 - 1723
  • [5] In vivo tear film thickness measurement and tear film dynamics visualization using spectral domain optical coherence tomography
    dos Santos, Valentin Aranha
    Schmetterer, Leopold
    Groeschl, Martin
    Garhofer, Gerhard
    Schmidl, Doreen
    Kucera, Martin
    Unterhuber, Angelika
    Hermand, Jean-Pierre
    Werkmeister, Rene M.
    OPTICS EXPRESS, 2015, 23 (16): : 21043 - 21063
  • [6] Application of maximum-likelihood estimation in optical coherence tomography for nanometer-class thickness estimation
    Huang, Jinxin
    Yuan, Qun
    Tankam, Patrice
    Clarkson, Eric
    Kupinski, Matthew
    Hindman, Holly B.
    Aquavella, James V.
    Rolland, Jannick P.
    Design and Quality for Biomedical Technologies VIII, 2015, 9315
  • [7] An imaging system integrating optical coherence tomography and interferometry for in vivo measurement of the thickness and dynamics of the tear film
    Yuqiang Bai
    William Ngo
    Boyu Gu
    Yuhua Zhang
    Jason J. Nichols
    BioMedical Engineering OnLine, 17
  • [8] An imaging system integrating optical coherence tomography and interferometry for in vivo measurement of the thickness and dynamics of the tear film
    Bai, Yuqiang
    Ngo, William
    Gu, Boyu
    Zhang, Yuhua
    Nichols, Jason J.
    BIOMEDICAL ENGINEERING ONLINE, 2018, 17
  • [9] Simultaneous measurement of lipid and aqueous layers of tear film using optical coherence tomography and statistical decision theory
    Huang, Jinxin
    Clarkson, Eric
    Kupinski, Matthew
    Rolland, Jannick P.
    DESIGN AND QUALITY FOR BIOMEDICAL TECHNOLOGIES VII, 2014, 8936
  • [10] Measurement of Tear Film Thickness Using Ultrahigh-Resolution Optical Coherence Tomography
    Werkmeister, Rene M.
    Alex, Aneesh
    Kaya, Semira
    Unterhuber, Angelika
    Hofer, Bernd
    Riedl, Jasmin
    Bronhagl, Michael
    Vietauer, Martin
    Schmidl, Doreen
    Schmoll, Tilman
    Garhoefer, Gerhard
    Drexler, Wolfgang
    Leitgeb, Rainer A.
    Groeschl, Martin
    Schmetterer, Leopold
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (08) : 5578 - 5583