Challenges in preparing soil samples and performing a reliable plutonium isotopic analysis by ICP-MS

被引:10
|
作者
Puzas, A. [1 ]
Genys, P. [2 ]
Remeikis, V. [1 ]
Druteikiene, R. [1 ]
机构
[1] Ctr Phys Sci & Technol, LT-02300 Vilnius, Lithuania
[2] Vilnius State Univ, LT-10222 Vilnius, Lithuania
关键词
Plutonium isotopes; ICP-MS; Uranium hydride; Lead chloride; Polyatomic interferences; PLASMA-MASS SPECTROMETRY; RATIO;
D O I
10.1007/s10967-014-3411-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Soil samples were prepared by performing ion exchange and extraction chromatography separation techniques and measured in the low resolution mode (m/Delta m = 300) using a standard nebulizer (1 mL/min, U-type, "Glass Expansion") and a cyclonic 50 mL spray chamber. With this configuration if plutonium concentration is in a sub-ppt range, (UH+)-U-238-H-1 must be taken into the account; however, taking into the account (UHH+)-U-238-H-1-H-1 is not necessary. In all cases it is strongly recommended to avoid using hydrochloric acid as a final stabilizing matrix and use the ultrapure nitric acid as it creates the lowest background at 239 and 240 m/z values.
引用
收藏
页码:751 / 759
页数:9
相关论文
共 50 条
  • [31] Analysis of different types of soil by FTIR and ICP-MS
    Liu, Gang, 1600, Science Press (34):
  • [32] Microwave-assisted Digestion of Environmental Soil Sample and Measurement of Plutonium by ICP-MS
    Xu H.
    Ma T.
    Li D.
    Zhan J.
    Wang Y.
    Wang B.
    Wang Y.
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2019, 53 (04): : 603 - 610
  • [33] Determination of uranium, thorium and plutonium isotopes by ICP-MS
    Y. Shi
    R. Collins
    C. Broome
    Journal of Radioanalytical and Nuclear Chemistry, 2013, 296 : 509 - 515
  • [34] Determination of uranium, thorium and plutonium isotopes by ICP-MS
    Shi, Y.
    Collins, R.
    Broome, C.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2013, 296 (01) : 509 - 515
  • [35] Chromatographic extraction of plutonium and inorganic impurity analysis using ICP-MS and ICP-AES
    Mahan, C
    Bonchin, S
    Figg, D
    Gerth, D
    Collier, C
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (08) : 929 - 935
  • [36] Determination of plutonium isotopes in seawater samples by Semiconductor Alpha Spectrometry, ICP-MS and AMS techniques
    S. H. Lee
    P. P. Povinec
    J. Gastaud
    J. J. La Rosa
    E. Wyse
    L. K. Fifield
    Journal of Radioanalytical and Nuclear Chemistry, 2009, 282
  • [37] ANALYSIS OF URANIUM AND RADIUM IN ENVIRONMENTAL-SAMPLES BY ICP-MS
    VARNON, W
    HENRY, R
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1995, 209 : 111 - NUCL
  • [38] Determination of plutonium isotopes in seawater samples by Semiconductor Alpha Spectrometry, ICP-MS and AMS techniques
    Lee, S. H.
    Povinec, P. P.
    Gastaud, J.
    La Rosa, J. J.
    Wyse, E.
    Fifield, L. K.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2009, 282 (03) : 831 - 835
  • [39] Plutonium isotope ratio analysis at femtogram to nanogram levels by multicollector ICP-MS
    Taylor, RN
    Warneke, T
    Milton, JA
    Croudace, IW
    Warwick, PE
    Nesbitt, RW
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (03) : 279 - 284
  • [40] APPLICATION OF ICP-MS TO ACCURATE ISOTOPIC ANALYSIS FOR HUMAN METABOLIC STUDIES
    TING, BTG
    JANGHORBANI, M
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1987, 42 (1-2) : 21 - 27