Thermal capsulorrhaphy treatment of shoulder instability - Basic science

被引:60
|
作者
Hayashi, K [1 ]
Markel, MD [1 ]
机构
[1] Univ Wisconsin, Comparat Orthopaed Res Lab, Madison, WI 53706 USA
关键词
D O I
10.1097/00003086-200109000-00009
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Thermal capsulorrhaphy is a new treatment modality for shoulder instability, where the joint capsular tissue is heated and reduced in length by laser or radiofrequency energy to regain joint stability. Experimental studies have shown that (1) joint capsular tissue can be modified significantly (shortened) by thermal energy at the temperature range of 70 degrees to 80 degrees C; (2) thermal energy causes immediate deleterious effects such as loss of the mechanical properties, collagen denaturation, and cell necrosis; (3) thermally treated tissue is repaired actively by a residual population of fibroblasts and vascular cells, with concomitant improvement of mechanical properties; (4) the shrunken tissue stretches with time if the tissue is subjected to physiologic loading immediately after surgery; and (5) leaving viable tissue between treated regions significantly improves the healing process. Therefore, the application of thermal energy to achieve joint stability relies on an initial effect (shrinkage), and to a great extent the tissue's healing response regain the tissue's mechanical properties. Particularly, induction of active repair and joint capsular thickening with tissue remodeling regulated by functional demand seem to be essential factors for a successful outcome. Thermal treatment causes an initial deleterious effect on the tissue's properties, and overtreatment can lead to severe immediate and permanent tissue damage. In addition, scientific data of newly developed devices are limited, and the information from manufacturers often is unreliable and misleading. Carefully controlled long-term clinical and scientific studies should be done to additionally clarify the advantages and disadvantages of this technique.
引用
收藏
页码:59 / 72
页数:14
相关论文
共 50 条
  • [41] POSTERIOR STAPLE CAPSULORRHAPHY REPAIR OF SHOULDER
    MITTON, AH
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1977, 59 (04): : 508 - 509
  • [42] OPERATIVE TREATMENT OF POSTERIOR SHOULDER DISLOCATIONS BY POSTERIOR GLENOIDPLASTY, CAPSULORRHAPHY, AND INFRASPINATUS ADVANCEMENT
    HERNANDEZ, A
    DREZ, D
    AMERICAN JOURNAL OF SPORTS MEDICINE, 1986, 14 (03): : 187 - 191
  • [43] Effect of simulated shoulder thermal capsulorrhaphy using radiofrequency energy on glenohumeral fluid temperature
    Lu, Y
    Bogdanske, J
    Lopez, M
    Cole, BJ
    Markel, MD
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2005, 21 (05): : 592 - 596
  • [44] Thermal capsulorrhaphy for isolated posterior instability of the glenohumeral joint without labral detachment
    Bisson, LJ
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2005, 33 (12): : 1898 - 1904
  • [45] Treatment of Pediatric Shoulder Instability
    Cil, Akin
    Kocher, Mininder S.
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2010, 30 : S3 - S6
  • [46] Evaluation and Treatment of Shoulder Instability
    Anakwenze, Oke A.
    Huffman, G. Russell
    PHYSICIAN AND SPORTSMEDICINE, 2011, 39 (02): : 149 - 157
  • [47] Arthroscopic treatment of shoulder instability
    Bartl, C
    Lichtenberg, S
    Habermeyer, P
    ZENTRALBLATT FUR CHIRURGIE, 2002, 127 (03): : 180 - 186
  • [48] Surgical treatment of shoulder instability
    Pucheu, B.
    Duhautois, B.
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2008, 21 (04) : 368 - 374
  • [49] STAPLE CAPSULORRHAPHY FOR RECURRENT POSTERIOR SHOULDER DISLOCATION
    TIBONE, JE
    PRIETTO, C
    JOBE, FW
    KERLAN, RW
    CARTER, VS
    SHIELDS, CL
    LOMBARDO, SJ
    COLLINS, HR
    YOCUM, LA
    AMERICAN JOURNAL OF SPORTS MEDICINE, 1981, 9 (03): : 135 - 139
  • [50] CAPSULORRHAPHY WITH A STAPLE FOR RECURRENT POSTERIOR SUBLUXATION OF THE SHOULDER
    TIBONE, J
    TING, A
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (07): : 999 - 1002