Identification and Control for Automated Regulation of Hemodynamic Variables During Hemodialysis

被引:14
|
作者
Javed, Faizan [1 ]
Savkin, Andrey V. [1 ]
Chan, Gregory S. H. [1 ]
Mackie, James D. [2 ]
Lovell, Nigel H. [3 ]
机构
[1] Univ New S Wales, Sch Elect Engn & Telecommun, Sydney, NSW 2052, Australia
[2] Prince Wales Hosp, Dept Nephrol, Sydney, NSW 2031, Australia
[3] Univ New S Wales, Grad Sch Biomed Engn, Sydney, NSW 2052, Australia
基金
澳大利亚研究理事会;
关键词
Adaptive control; blood volume monitoring; linear time varying system; model predictive control; BLOOD-VOLUME; DIALYSIS HYPOTENSION; PREVENTION;
D O I
10.1109/TBME.2011.2110650
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper proposes a novel model-based control methodology for a computer-controlled hemodialysis system, designed to maintain the hemodynamic stability of end-stage renal failure patients undergoing fluid removal during hemodialysis. The first objective of this paper is to introduce a linear parameter varying system to model the hemodynamic response of patients during hemodialysis. Ultrafiltration rate (UFR) and dialysate sodium concentration (DSC) are imposed as the inputs, and the model computes the relative blood volume (RBV), percentage change in heart rate (Delta HR), and systolic blood pressure (SBP) during the course of hemodialysis. The model parameters were estimated based on data collected from 12 patients undergoing 4 profiled hemodialysis sessions. The modeling results demonstrated that the proposed model could be useful for estimating the individual patient's hemodynamic behavior during hemodialysis. Based on the model, the second objective is to implement a computer-controlled hemodialysis system for the regulation of RBV and HR during hemodialysis while maintaining SBP within stable range. The proposed controller is based on a model predictive control approach utilizing pre-defined constraints on the control inputs (UFR and DSC) as well as the output (SBP). The designed control system was experimentally verified on four patients. The results demonstrated that the proposed computer-controlled hemodialysis system regulated the RBV and HR of the patients according to individual reference profiles with an average mean square error of 0.24% and 2.6%, respectively, and thus can be potentially useful for ensuring the stability of patients undergoing hemodialysis by avoiding sudden changes in hemodynamic variables.
引用
收藏
页码:1686 / 1697
页数:12
相关论文
共 50 条
  • [1] Automated regulation of hemodynamic variables
    Rao, RR
    Palerm, CC
    Aufderheide, B
    Bequette, BW
    [J]. IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 2001, 20 (01): : 24 - 38
  • [2] Modeling and Model Predictive Control of Hemodynamic Variables during Hemodialysis
    Javed, Faizan
    Savkin, Andrey V.
    Chan, Gregory S. H.
    Mackie, James D.
    [J]. 49TH IEEE CONFERENCE ON DECISION AND CONTROL (CDC), 2010, : 4673 - 4678
  • [3] Experimental studies on multiple-model predictive control for automated regulation of hemodynamic variables
    Rao, RR
    Aufderheide, B
    Bequette, BW
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2003, 50 (03) : 277 - 288
  • [4] Automated hemodynamic regulation with model predictive control
    Aufderheide, B
    Rao, RR
    Bequette, BW
    [J]. PROCEEDINGS OF THE IEEE 25TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE, 1999, : 73 - 74
  • [5] HEMODYNAMIC INSTABILITY DURING HEMODIALYSIS
    HENRICH, WL
    [J]. KIDNEY INTERNATIONAL, 1986, 30 (04) : 605 - 612
  • [6] Hemodynamic monitoring during hemodialysis
    Leypoldt, JK
    Lindsay, RM
    [J]. ADVANCES IN RENAL REPLACEMENT THERAPY, 1999, 6 (03): : 233 - 242
  • [7] HEMODYNAMIC CHANGES DURING HEMODIALYSIS
    GOSS, JE
    ALFREY, AC
    VOGEL, JHK
    HOLMES, JH
    [J]. TRANSACTIONS AMERICAN SOCIETY FOR ARTIFICIAL INTERNAL ORGANS, 1967, 13 (APR): : 68 - &
  • [8] HEMODYNAMIC CHANGES DURING HEMODIALYSIS
    ENDOU, K
    KAMIJIMA, J
    KAKUBARI, Y
    KIKAWADA, R
    [J]. CARDIOLOGY, 1978, 63 (03) : 175 - 187
  • [9] HEMODYNAMIC REGULATION (3RD REPORT) - FLUID EXCHANGES DURING HEMODIALYSIS
    TAJIRI, M
    KAMIMURA, A
    YUASA, Y
    SAKAI, S
    SUZUKI, M
    TAKAHASHI, S
    IMAI, K
    IKEDA, T
    HIRASAWA, Y
    AIZAWA, Y
    SHIBATA, A
    [J]. JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1979, 43 (07): : 709 - 709
  • [10] Genetic regulation of hemodynamic variables during dynamic exercise - The MCV twin study
    vandenBree, MBM
    Schieken, RM
    Moskowitz, WB
    Eaves, LJ
    [J]. CIRCULATION, 1996, 94 (08) : 1864 - 1869