Approximation of Resting Energy Expenditure in Intensive Care Unit Patients Using the SenseWear Bracelet: A Comparison With Indirect Calorimetry

被引:0
|
作者
Sundstrom, Martin [1 ]
Mehrabi, Mahboubeh [2 ]
Tjader, Inga [1 ]
Rooyackers, Olav [1 ]
Hammarqvist, Folke [2 ]
机构
[1] Karolinska Univ, Karolinska Inst, Huddinge Hosp, Dept Anaesthesiol & Intens Care,CLINTEC,Clin Inte, Stockholm, Sweden
[2] Karolinska Univ, Huddinge Hosp, Karolinska Inst, Gastroctr,Dept Surg,CLINTEC,Clin Intervent & Tech, Stockholm, Sweden
关键词
energy expenditure; nutrition; intensive care unit; indirect calorimetry; SenseWear; Deltatrac;
D O I
10.1177/0148607116633808
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Background and Aims: Indirect calorimetry (IC) is the gold standard for determining energy expenditure in patients requiring mechanical ventilation. Metabolic armbands using data derived from dermal measurements have been proposed as an alternative to IC in healthy subjects, but their utility during critical illness is unclear. The aim of this study was to determine the level of agreement between the SenseWear armband and the Deltatrac Metabolic Monitor in mechanically ventilated intensive care unit (ICU) patients. Methods: Adult ICU patients requiring invasive ventilator therapy were eligible for inclusion. Simultaneous measurements were performed with the SenseWear Armband and Deltatrac under stable conditions. Resting energy expenditure (REE) values were registered for both instruments and compared with Bland-Altman plots. Results: Forty-two measurements were performed in 30 patients. The SenseWear Armband measured significantly higher REE values as compared with IC (mean bias, 85 kcal/24 h; P = .027). Less variability was noted between individual SenseWear measurements and REE as predicted by the Harris-Benedict equation (2 SD, +/- 327 kcal/24 h) than when IC was compared with SenseWear and Harris-Benedict (2 SD, +/- 473 and +/- 543 kcal/24 h, respectively). Conclusions: The systematic bias and large variability of the SenseWear armband when compared with gas exchange measurements confer limited benefits over the Harris Benedict equation in determining caloric requirements of ICU patients.
引用
收藏
页码:976 / 980
页数:5
相关论文
共 50 条
  • [41] Validity of resting energy expenditure estimated by an activity monitor compared to indirect calorimetry
    Dellava, Jocilyn E.
    Hoffman, Daniel J.
    BRITISH JOURNAL OF NUTRITION, 2009, 102 (01) : 155 - 159
  • [42] A SIMPLE AND ACCURATE INDIRECT CALORIMETRY SYSTEM FOR ASSESSMENT OF RESTING ENERGY-EXPENDITURE
    HEAD, CA
    MCMANUS, CB
    SEITZ, S
    GROSSMAN, GD
    STATON, GW
    HEYMSFIELD, SB
    JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 1984, 8 (01) : 45 - 48
  • [43] Resting energy expenditure in patients with cirrhosis of the liver measured by indirect calorimetry, anthropometry and bioelectrical impedance analysis
    Waluga, M
    ZahorskaMarkiewicz, B
    Janusz, M
    Slabiak, Z
    Chelmicka, A
    EXPERIENTIA, 1996, 52 (06): : 591 - 596
  • [44] Resting Energy Expenditure Measured by Indirect Calorimetry in Obese Patients: Variation Within Different BMI Ranges
    Fabiano Alves, Valeria Girard
    Moreira da Rocha, Eduardo Eiras
    Gonzalez, Maria Cristina
    Vieira Fonseca, Rosana Barcellos
    do Nascimento Silva, Monica Hissa
    JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 2020, 44 (01) : 129 - 137
  • [45] INDIRECT CALORIMETRY AS A MEANS OF ASSESSING THE NUTRITIONAL STATUS OF PATIENTS IN THE PEDIATRIC INTENSIVE CARE UNIT
    Taylor, Ryan
    Saikali, Diana
    Kelly, Robert
    CRITICAL CARE MEDICINE, 2010, 38 (12) : U74 - U74
  • [46] Energy Expenditure In Elderly Critically Ill Patients - A Comparison Of Indirect Calorimetry With Established Formulas
    Blaser, D.
    Elke, G.
    Kott, M.
    Frerichs, I.
    Weiler, N.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2013, 187
  • [47] Evaluating steady-state resting energy expenditure using indirect calorimetry in adults with overweight and obesity
    Popp, C. J.
    Butler, M.
    Curran, M.
    Illiano, P.
    Sevick, M. A.
    St-Jules, D. E.
    CLINICAL NUTRITION, 2020, 39 (07) : 2220 - 2226
  • [48] INDIRECT CALORIMETRY - COMPARISON OF HOOD AND MASK SYSTEMS FOR MEASURING RESTING ENERGY-EXPENDITURE IN HEALTHY-VOLUNTEERS
    MCANENA, OJ
    HARVEY, LP
    KATZEFF, HL
    DALY, JM
    JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 1986, 10 (06) : 555 - 557
  • [49] Accuracy of a Portable Multisensor Body Monitor for Predicting Resting Energy Expenditure in Older People: A Comparison with Indirect Calorimetry
    Heiermann, Stefanie
    Hedayati, Kerstin Khalaj
    Mueller, Manfred J.
    Dittmar, Manuela
    GERONTOLOGY, 2011, 57 (05) : 473 - 479
  • [50] INFLUENCE OF VARIOUS FACTORS ON RESTING ENERGY-EXPENDITURE IN MECHANICALLY VENTILATED PATIENTS IN A NEUROSURGICAL INTENSIVE-CARE UNIT
    PIEK, J
    BRACHWITZ, K
    ZANKE, T
    MAURER, R
    BOCK, WJ
    INFUSIONSTHERAPIE UND TRANSFUSIONSMEDIZIN, 1988, 15 (01): : 8 - 9