Digital Subtraction CT Angiography for Detection of Intracranial Aneurysms: Comparison with Three-dimensional Digital Subtraction Angiography

被引:76
|
作者
Lu, Li [1 ]
Zhang, Long Jiang [1 ]
Poon, Colin S. [2 ]
Wu, Sheng Yong [3 ]
Zhou, Chang Sheng [1 ]
Luo, Song [1 ]
Wang, Mei [1 ]
Lu, Guang Ming [1 ]
机构
[1] Nanjing Univ, Dept Med Imaging, Jinling Hosp, Med Coll,Clin Sch, Nanjing 210002, Jiangsu, Peoples R China
[2] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
[3] Med Imaging Inst Tianjin, Tianjin, Peoples R China
关键词
COMPUTED-TOMOGRAPHY ANGIOGRAPHY; MULTISLICE CT; CONVENTIONAL ANGIOGRAPHY; SUBARACHNOID HEMORRHAGE; ARTERY ANEURYSMS; IMAGE QUALITY; DIAGNOSIS; RUPTURE; DSA;
D O I
10.1148/radiol.11110486
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the diagnostic accuracy of digital subtraction computed tomographic (CT) angiography in the detection of intracranial aneurysms compared with three-dimensional (3D) rotational digital subtraction angiography (DSA), as reference standard, in a large cohort in a single center. Materials and Methods: The study was waived by the institutional review board because of its retrospective nature. A total of 513 patients clinically suspected of having or with known intracranial aneurysms and other cerebral vascular diseases underwent both digital subtraction CT angiography with a dual-source CT scanner and 3D DSA, with a median interval of 1 day; 436 patients (84.9%) had acute subarachnoid hemorrhage at presentation. The sensitivity, specificity, and accuracy of digital subtraction CT angiography in depicting aneurysm were analyzed on a per-patient and per-aneurysm basis, with 3D DSA as the reference standard. The sensitivity, specificity, and accuracy of digital subtraction CT angiography in depicting aneurysms of different diameter (ie, < 3 mm, 3-5 mm, 5-10 mm, and > 10 mm) and of aneurysms at different locations in the anterior and posterior circulation were calculated. Kappa statistics were calculated to quantify inter-and intrareader variability in detecting aneurysms by using digital subtraction CT angiography for 100 patients. Results: Of 513 patients, 106 (20.7%) had no aneurysms, while 407 patients (79.3%) had 459 aneurysms at 3D DSA. Digital subtraction CT angiography correctly depicted 456 (99.3%) of the 459 aneurysms. By using 3D DSA as the standard of reference, the sensitivity and specificity of depicting intracranial aneurysms were 97.8% (398 of 407) and 88.7% (94 of 106), respectively, on a per-patient basis, and 96.5% (443 of 459) and 87.8% (94 of 107), respectively, on a per-aneurysm basis. Digital subtraction CT angiography had sensitivities of 91.3% (42 of 46), 94.0% (140 of 149), 98.4% (186 of 189), and 100% (75 of 75) in depicting aneurysms of less than 3 mm, between 3 mm but less than 5 mm, between 5 mm but less than 10 mm, and 10 mm or greater, respectively, and of 95.8% (276 of 288) and 97.7% (167 of 171) in depicting anterior circulation and posterior circulation aneurysms, respectively. Excellent inter-and intrareader agreement was found on a per-patient (kappa = 0.900 and 0.939, both P < .001) and per-aneurysm basis (kappa = 0.846 and 0.921, both P < .001) for the detection of intracranial aneurysms with digital subtraction CT angiography. Conclusion: Digital subtraction CT angiography has a high sensitivity and specificity in depicting intracranial aneurysms with different sizes and at different locations, compared with 3D DSA. (C)RSNA, 2011
引用
收藏
页码:605 / 612
页数:8
相关论文
共 50 条
  • [31] Subtraction CT angiography for evaluation of intracranial aneurysms: comparison with conventional CT angiography
    Li, Qi
    Lv, Fajin
    Li, Yongmei
    Li, Kewei
    Luo, Tianyou
    Xie, Peng
    [J]. EUROPEAN RADIOLOGY, 2009, 19 (09) : 2261 - 2267
  • [32] Subtraction CT angiography for evaluation of intracranial aneurysms: comparison with conventional CT angiography
    Qi Li
    Fajin Lv
    Yongmei Li
    Kewei Li
    Tianyou Luo
    Peng Xie
    [J]. European Radiology, 2009, 19 : 2261 - 2267
  • [33] Spiral CT of intracranial aneurysms: Correlation with digital subtraction and magnetic resonance angiography
    Wilms, G
    Guffens, M
    Gryspeerdt, S
    Bosmans, H
    Maaly, M
    Boulanger, T
    VanHoe, L
    Marchal, G
    Baert, A
    [J]. NEURORADIOLOGY, 1996, 38 : S20 - S25
  • [34] Multislice computerized tomography angiography in the evaluation of intracranial aneurysms: a comparison with intraarterial digital subtraction angiography
    Wintermark, M
    Uske, A
    Chalaron, M
    Regli, L
    Maeder, P
    Meuli, R
    Schnyder, P
    Binaghi, S
    [J]. JOURNAL OF NEUROSURGERY, 2003, 98 (04) : 828 - 836
  • [35] INTRAARTERIAL DIGITAL SUBTRACTION ANGIOGRAPHY FOR DEFINITIVE DIAGNOSIS OF INTRACRANIAL ANEURYSMS
    TOUHO, H
    KARASAWA, J
    TAZAWA, T
    NAKAGAWARA, J
    YAMADA, K
    KOBAYASHI, K
    ASAI, M
    KAGAWA, M
    YASUE, H
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 1988, 9 (06) : 1157 - 1161
  • [36] Preoperative Digital Subtraction Angiography in Incidental Unruptured Intracranial Aneurysms
    Herzberg, Moriz
    Forbrig, Robert
    Schichor, Christian
    Brueckmann, Hartmut
    Dorn, Franziska
    [J]. CLINICAL NEURORADIOLOGY, 2018, 28 (03) : 429 - 435
  • [37] INTRACRANIAL APPLICATIONS OF DIGITAL SUBTRACTION ANGIOGRAPHY
    CARMODY, RF
    SEEGER, JF
    [J]. CRC CRITICAL REVIEWS IN DIAGNOSTIC IMAGING, 1984, 23 (01) : 1 - 40
  • [38] Multi-slice CT-angiography of intracranial aneurysms: Comparative evaluation with digital subtraction angiography
    Freund, M
    Moeller, M
    Fischbach, RM
    Greiner, C
    Wassmann, H
    Heindel, WL
    [J]. RADIOLOGY, 2001, 221 : 527 - 527
  • [39] DETECTION OF CIRCLE OF WILLIS ANEURYSMS IN PATIENTS WITH ACUTE SUBARACHNOID HEMORRHAGE - A COMPARISON OF CT ANGIOGRAPHY AND DIGITAL SUBTRACTION ANGIOGRAPHY
    VIECO, PT
    SHUMAN, WP
    ALSOFROM, GF
    GROSS, CE
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (02) : 425 - 430
  • [40] MULTIANGULAR DIGITAL SUBTRACTION ANGIOGRAPHY APPLIED TO INTRACRANIAL ANGIOGRAPHY
    OSBORN, AG
    HARNSBERGER, HR
    COIT, WE
    KRUGER, RA
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 1986, 7 (03) : 554 - 554