Normative data for a user-friendly paradigm for pattern electroretinogram recording

被引:99
|
作者
Porciatti, V [1 ]
Ventura, LM [1 ]
机构
[1] Bascom Palmer Eye Inst, Miami, FL 33136 USA
关键词
D O I
10.1016/j.ophtha.2003.04.007
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To provide normative data for a user-friendly paradigm for the pattern electroretinogram (PERG) optimized for glaucoma screening (PERGLA). Design: Prospective nonrandomized case series. Participants: Ninety-three normal subjects ranging in age between 22 and 85 years. Methods: A circular black-white grating of 250 visual angle, reversing 16.28 times per second, was presented on a television monitor placed inside a Ganzfeld bowl. The PERG was recorded simultaneously from both eyes with undilated pupils by means of skin cup electrodes taped over the lower eyelids. Reference electrodes were taped on the ipsilateral temples. Electrophysiologic signals were conventionally amplified, filtered, and digitized. Six hundred artifact-free repetitions were averaged. The response component at the reversal frequency was isolated automatically by digital Fourier transforms and was expressed as a deviation from the age-corrected average. The procedure took approximately 4 minutes. Main Outcome Measures: Pattern electroretinogram amplitude (muV) and phase (pi rad); response variability (coefficient of variation [CV] = standard deviation [SD] / mean X 100) of amplitude and phase of 2 partial averages that build up the PERG waveform; amplitude (muV) of background noise waveform, obtained by multiplying alternate sweeps by + 1 and - 1; and interocular asymmetry (CV of amplitude and phase of the PERG of the 2 eyes). Results: On average, the PERG has a signal-to-noise ratio of more than 13:1. The CVs of intrasession and intersession variabilities in amplitude and phase are lower than 10% and 2%, respectively, and do not depend on the operator. The CV of interocular asymmetries in amplitude and phase are 9.8+/-8.8% and 1.5+/-1.4%, respectively. The PERG amplitude and phase decrease with age. Residuals of linear regression lines have normal distribution, with an SD of 0.1 log units for amplitude and 0.019 log units for phase. Age-corrected confidence limits (P<0.05) are defined as 2 SD of residuals. Conclusions: The PERGLA paradigm yields responses as reliable as the best previously reported using standard protocols. The ease of execution and interpretation of results of PERGLA indicate a potential value for objective screening and follow-up of glaucoma.
引用
收藏
页码:161 / 168
页数:8
相关论文
共 50 条
  • [41] genomeSidekick: A user-friendly epigenomics data analysis tool
    Chen, Junjie
    Zhu, Ashley J.
    Packard, Rene R. S.
    Vondriska, Thomas M.
    Chapski, Douglas J.
    FRONTIERS IN BIOINFORMATICS, 2022, 2
  • [42] Production Analytics - User-friendly Evaluation of Production Data
    Schuh G.
    Prote J.-P.
    Sauermann F.
    Schmitz S.
    ZWF Zeitschrift fuer Wirtschaftlichen Fabrikbetrieb, 2019, 114 (09): : 588 - 591
  • [43] LuxDrops - User-Friendly Management of Confidential Data in the Cloud
    Bauler, Pascal
    Heinesch, Daniel
    Schlechter, Antoine
    Feltz, Fernand
    ERCIM NEWS, 2013, (94): : 32 - 33
  • [44] THE (+/-) REFERENCE IN PATTERN ELECTRORETINOGRAM RECORDING
    BOBAK, P
    OPTOMETRY AND VISION SCIENCE, 1989, 66 (04) : 214 - 217
  • [45] A Wide-band and User-friendly EEG Recording System for Wearable Applications
    Bisoni, Lorenzo
    Mastinu, Enzo
    Barbaro, Massimo
    BIODEVICES: PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON BIOMEDICAL ELECTRONICS AND DEVICES, 2015, : 29 - 36
  • [46] A semantically integrated, user-friendly data model for species observation data
    Veen, L. E.
    van Reenen, G. B. A.
    Sluiter, F. P.
    van Loon, E. E.
    Bouten, W.
    ECOLOGICAL INFORMATICS, 2012, 8 : 1 - 9
  • [47] Unintended Consequences: A Friendly User Looks at User-Friendly Digitization
    Siggins, Jack A.
    JOURNAL OF LIBRARY ADMINISTRATION, 2008, 48 (02) : 195 - 206
  • [48] More User-Friendly Metrics
    Krauskopf, Erwin
    BRAZILIAN JOURNAL OF CARDIOVASCULAR SURGERY, 2019, 34 (04) : 503 - 503
  • [49] MAKING THE JOURNAL USER-FRIENDLY
    COHEN, HJ
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1991, 52 (07): : A381 - A382
  • [50] A user-friendly graphical user interface for dynamic light scattering data analysis
    Salazar, Matthew
    Srivastav, Harsh
    Srivastava, Abhishek
    Srivastava, Samanvaya
    SOFT MATTER, 2023, 19 (34) : 6535 - 6544