Normative data for a user-friendly paradigm for pattern electroretinogram recording

被引:99
|
作者
Porciatti, V [1 ]
Ventura, LM [1 ]
机构
[1] Bascom Palmer Eye Inst, Miami, FL 33136 USA
关键词
D O I
10.1016/j.ophtha.2003.04.007
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To provide normative data for a user-friendly paradigm for the pattern electroretinogram (PERG) optimized for glaucoma screening (PERGLA). Design: Prospective nonrandomized case series. Participants: Ninety-three normal subjects ranging in age between 22 and 85 years. Methods: A circular black-white grating of 250 visual angle, reversing 16.28 times per second, was presented on a television monitor placed inside a Ganzfeld bowl. The PERG was recorded simultaneously from both eyes with undilated pupils by means of skin cup electrodes taped over the lower eyelids. Reference electrodes were taped on the ipsilateral temples. Electrophysiologic signals were conventionally amplified, filtered, and digitized. Six hundred artifact-free repetitions were averaged. The response component at the reversal frequency was isolated automatically by digital Fourier transforms and was expressed as a deviation from the age-corrected average. The procedure took approximately 4 minutes. Main Outcome Measures: Pattern electroretinogram amplitude (muV) and phase (pi rad); response variability (coefficient of variation [CV] = standard deviation [SD] / mean X 100) of amplitude and phase of 2 partial averages that build up the PERG waveform; amplitude (muV) of background noise waveform, obtained by multiplying alternate sweeps by + 1 and - 1; and interocular asymmetry (CV of amplitude and phase of the PERG of the 2 eyes). Results: On average, the PERG has a signal-to-noise ratio of more than 13:1. The CVs of intrasession and intersession variabilities in amplitude and phase are lower than 10% and 2%, respectively, and do not depend on the operator. The CV of interocular asymmetries in amplitude and phase are 9.8+/-8.8% and 1.5+/-1.4%, respectively. The PERG amplitude and phase decrease with age. Residuals of linear regression lines have normal distribution, with an SD of 0.1 log units for amplitude and 0.019 log units for phase. Age-corrected confidence limits (P<0.05) are defined as 2 SD of residuals. Conclusions: The PERGLA paradigm yields responses as reliable as the best previously reported using standard protocols. The ease of execution and interpretation of results of PERGLA indicate a potential value for objective screening and follow-up of glaucoma.
引用
收藏
页码:161 / 168
页数:8
相关论文
共 50 条
  • [1] A User-Friendly Patent Search Paradigm
    Cao, Yang
    Fan, Ju
    Li, Guoliang
    [J]. IEEE TRANSACTIONS ON KNOWLEDGE AND DATA ENGINEERING, 2013, 25 (06) : 1439 - 1443
  • [2] A USER-FRIENDLY PC DATA SYSTEM
    WORTHINGTON, SLS
    SCHMIDT, RW
    [J]. AMERICAN LABORATORY, 1987, 19 (06) : 108 - &
  • [3] LOGIT - USER-FRIENDLY DATA LOGGING
    LANE, SJ
    [J]. TERRA NOVA, 1994, 6 (02) : 202 - 206
  • [4] User-friendly
    Riddoch, S
    [J]. AUSTRALIAN JOURNAL OF PHYSIOTHERAPY, 1999, 45 (02): : 142 - 142
  • [5] USER-FRIENDLY
    YOUNG, N
    [J]. BRITISH DENTAL JOURNAL, 1994, 177 (03) : 86 - 86
  • [6] User-friendly
    马而
    [J]. 黑河教育, 1994, (04) : 40 - 40
  • [7] User-friendly
    董校庭
    [J]. 上海翻译, 1986, (03) : 3 - 3
  • [8] User-Friendly
    Schillinger, Jakob
    [J]. ARTFORUM INTERNATIONAL, 2012, 51 (03): : 127 - 128
  • [9] User-Friendly Access to Structured Environmental Data
    Abecker, Andreas
    Bicer, Veli
    Kazakos, Wassilios
    Nagypal, Gabor
    Nedkov, Radoslav
    Valikov, Aleksei
    [J]. ENVIRONMENTAL SOFTWARE SYSTEMS: FRAMEWORKS OF EENVIRONMENT, 2011, 359 : 357 - +
  • [10] A User-Friendly Introduction to Panel Data Modeling
    Worrall, John
    [J]. JOURNAL OF CRIMINAL JUSTICE EDUCATION, 2010, 21 (02) : 182 - 196