Liquid chromatography coupled to Venturi easy ambient sonic spray ionization mass spectrometry

被引:2
|
作者
Campos Oliveira, Luan Felipe [1 ]
Tega, David Ulisses [1 ]
Eberlin, Marcos Nogueira [2 ]
Sussulini, Alessandra [1 ]
机构
[1] Univ Campinas UNICAMP, Inst Chem, Dept Analyt Chem, Lab Bioanalyt & Integrated Omics LaBI, BR-13083970 Campinas, SP, Brazil
[2] Univ Prebiteriana Mackenzie, Sch Engn, BR-01302907 Sao Paulo, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Venturi easy ambient sonic-spray ionization; mass spectrometry; Annatto analysis; Liquid chromatography; Analytical methods; Ambient ionization; REAL-TIME ANALYSIS; INTERFACE; ASPIRATION; TISSUE; MS;
D O I
10.1016/j.talanta.2021.123004
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Venturi easy ambient sonic spray ionization (V-EASI) is a soft ambient ionization (AI) source that has the advantages of being suitable to the analysis of samples in solution (differently from the majority of AI sources), performing self-pumping, voltage- and heat-free ionization, and requiring minimum or no sample preparation. Since this ionization technique has not been fully explored, the present study provides a proof of principle of the coupling of liquid chromatography to mass spectrometry (LC-MS) using V-EASI as the interface. In order to test the performance of the developed LC-V-EASI-MS system, a quantification method for bixin, a natural dye from annatto (Bixa Orellana L.), which is known to be sensitive to the high voltage applied for electrospray ionization mass spectrometry (ESI-MS) analysis, was validated according to FDA criteria and tested in real samples. The analytical method was successfully applied and met the validation criteria, providing a detectability 10 times better than methods already reported to the quantification of bixin and no matrix effect was observed. Therefore, this proof of principle contributes to the continuous development of AI sources that represents the last great technological advance in MS towards becoming a miniaturized technique able to analyze samples closer to their actual state.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Food quality and authenticity screening via easy ambient sonic-spray ionization mass spectrometry
    Porcari, Andreia M.
    Fernandes, Gabriel D.
    Barrera-Arellano, Daniel
    Eberlin, Marcos N.
    Alberici, Rosana M.
    ANALYST, 2016, 141 (04) : 1172 - 1184
  • [22] A compact 3D-printed interface for coupling open digital microchips with Venturi easy ambient sonic-spray ionization mass spectrometry
    Hu, Jie-Bi
    Chen, Ting-Ru
    Chang, Chia-Hsien
    Cheng, Ji-Yen
    Chen, Yu-Chie
    Urban, Pawel L.
    ANALYST, 2015, 140 (05) : 1495 - 1501
  • [23] Caffeine quantification in dietary supplements using high-throughput on-line solid phase extraction coupled to Venturi easy ambient sonic-spray ionization mass spectrometry
    Tega, David Ulisses
    Oliveira, Luan Felipe Campos
    Ferreira, Patrick Cesar
    Soldera, Bruna Beatriz
    Nascimento, Heliara Dalva Lopes
    Eberlin, Marcos Nogueira
    Sussulini, Alessandra
    ANALYTICAL METHODS, 2024, 16 (17) : 2678 - 2683
  • [24] Monitoring binding affinity between drug and α1-acid glycoprotein in real time by Venturi easy ambient sonic-spray ionization mass spectrometry
    Liu, Ning
    Lu, Xin
    Yang, YuHan
    Yao, Chen Xi
    Ning, BaoMing
    He, Dacheng
    He, Lan
    Ouyang, Jin
    TALANTA, 2015, 143 : 240 - 244
  • [25] Direct monitoring of drug degradation by easy ambient sonic-spray ionization mass spectrometry: the case of enalapril
    Amaral, Phellipe H.
    Fernandes, Raquel
    Eberlin, Marcos N.
    Hoeehr, Nelci F.
    JOURNAL OF MASS SPECTROMETRY, 2011, 46 (12): : 1269 - U27
  • [26] Free and Total Glycerin in Biodiesel: Accurate Quantitation by Easy Ambient Sonic-Spray Ionization Mass Spectrometry
    Fernandes, Anna Maria A. P.
    Tega, David U.
    Jara, Jose L. P.
    Cunha, Ildenize B. S.
    de Sa, Gilberto F.
    Daroda, Romeu J.
    Eberlin, Marcos N.
    Alberici, Rosana M.
    ENERGY & FUELS, 2012, 26 (05) : 3042 - 3047
  • [27] Rapid analysis of pentazocine in human plasma by liquid chromatography/mass spectrometry with sonic spray ionization
    Arinobu, T
    Hattori, H
    Ishii, A
    Kumazawa, T
    Lee, XP
    Kojima, S
    Suzuki, O
    Seno, H
    ANALYTICA CHIMICA ACTA, 2003, 492 (1-2) : 249 - 252
  • [28] Ambient Mass Spectrometry Imaging: A Comparison of Desorption Ionization by Sonic Spray and Electrospray
    Janfelt, Christian
    Norgaard, Asger W.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2012, 23 (10) : 1670 - 1678
  • [29] Perfume fingerprinting by easy ambient sonic-spray ionization mass spectrometry: nearly instantaneous typification and counterfeit detection
    Haddad, Renato
    Catharino, Rodrigo Ramos
    Marques, Lygia Azevedo
    Eberlin, Marcos Nogueira
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (22) : 3662 - 3666
  • [30] Rapid and direct detection of artificially aged papers employing easy ambient sonic-spray ionization mass spectrometry
    Oliveira, Luan Felipe Campos
    de Morais, Damila Rodrigues
    Correa, Deleon Nascimento
    de Morais Campelo, Jacqueline
    Sussulini, Alessandra
    Eberlin, Marcos Nogueira
    Santos, Jandyson Machado
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2021, 35 (09)