Intraoperative nerve monitoring during esophagectomy reduces the risk of recurrent laryngeal nerve palsy

被引:8
|
作者
Yuda, Masami [1 ]
Nishikawa, Katsunori [2 ]
Ishikawa, Yoshitaka [2 ]
Takahashi, Keita [2 ]
Kurogochi, Takanori [2 ]
Tanaka, Yujiro [2 ]
Matsumoto, Akira [2 ]
Tanishima, Yuichiro [2 ]
Mitsumori, Norio [2 ]
Ikegami, Toru [2 ]
机构
[1] Jikei Univ Kashiwa Hosp, Dept Surg, 163 1 Kashiwashita Kashiwa Shi, Chiba 2778567, Japan
[2] Jikei Univ, Dept Surg Gastroenterol, Sch Med, Tokyo, Japan
关键词
Intraoperative nerve monitoring; Recurrent laryngeal nerve palsy; Esophagectomy; Esophageal cancer; Postoperative pneumonia; 3-FIELD LYMPHADENECTOMY; PULMONARY COMPLICATIONS; CANCER; IMPACT; TERM; IMPROVEMENT; MANAGEMENT; PARALYSIS; CARCINOMA; INJURY;
D O I
10.1007/s00464-021-08716-3
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background Despite the risk of recurrent laryngeal nerve (RLN) palsy during esophagectomy, no established method of monitoring RLN injury is currently available. Methods This study included 187 patients who underwent esophagectomy between 2011 and 2018. Among these, intraoperative nerve monitoring (IONM) was done in 142 patients (IONM group), while the remaining 45 patients underwent conventional surgery without IONM (control group). We investigated the incidence of postoperative complications with regard to the use of IONM. Results The overall incidence of postoperative RLN palsy was 28% (52/187). The IONM group showed a significantly lower incidence of postoperative RLN palsy as compared to that in the control group (p = 0.004). The overall incidence of postoperative pneumonia was 22% (41/187) in those with Clavien-Dindo (CD) classification beyond grade 2. There were no significant differences between the incidence of any grade of postoperative pneumonia and the use of IONM (p = 0.195 and 0.333; CD > 2 and > 3, respectively). Multivariate analysis demonstrated that tumors in the upper third [odds ratio (OR) 3.12; 95% confidence interval (CI) 1.04-9.29] and lack of IONM use (OR 2.51; 95% CI 1.17-5.38) were independent factors causing postoperative RLN palsy after esophagectomy. Conclusion IONM helps to reduce the risk of postoperative RLN palsy after esophageal cancer surgery.
引用
收藏
页码:3957 / 3964
页数:8
相关论文
共 50 条
  • [31] Intraoperative monitoring of the recurrent laryngeal nerve in thyroid surgery
    Salmoiraghi, F.
    Peloni, G.
    Brenna, M.
    Fasolini, F.
    BRITISH JOURNAL OF SURGERY, 2015, 102 : 17 - 17
  • [32] Intraoperative recurrent laryngeal nerve monitoring in revision thyroidectomy
    Prokopakis, Emmanuel
    Kaprana, Antigoni
    Velegrakis, Stylianos
    Panagiotaki, Irene
    Chatzakis, Nikolaos
    Iro, Heinrich
    Velegrakis, George
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2013, 270 (09) : 2521 - 2524
  • [33] Intraoperative monitoring of the recurrent laryngeal nerve in thyroid surgery
    Dralle, H.
    Sekulla, C.
    Lorenz, K.
    Brauckhoff, M.
    Machens, A.
    WORLD JOURNAL OF SURGERY, 2008, 32 (07) : 1358 - 1366
  • [34] Intraoperative recurrent laryngeal nerve monitoring in thyroid surgery
    Farris, S.
    Tatti, A.
    Piga, G.
    Podda, M.
    Calo, P. G.
    Pisano, G.
    Nicolosi, A.
    GIORNALE DI CHIRURGIA, 2010, 31 (6-7): : 353 - 353
  • [35] Intraoperative monitoring of the recurrent laryngeal nerve: A new method
    Lamade, W
    Fogel, W
    Rieke, K
    Senninger, N
    Herfarth, C
    CHIRURG, 1996, 67 (04): : 451 - 454
  • [36] Intraoperative Laryngeal Nerve Monitoring During Thyroidectomy
    Donnellan, Kimberly A.
    Pitman, Karen T.
    Cannon, C. Ron
    Replogle, William H.
    Simmons, Jon D.
    ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2009, 135 (12) : 1196 - 1198
  • [37] Combined Intraoperative Identification and Monitoring of Recurrent Laryngeal Nerve Paresis during Minimally Invasive Esophagectomy: Surgical Technique Using Nerve Integrity Monitoring for Esophageal Carcinoma
    Nitta, Toshikatsu
    Kawai, Masaru
    Kataoka, Jun
    Ohta, Masato
    Tashiro, Keitaro
    Ishibashi, Takashi
    CASE REPORTS IN GASTROENTEROLOGY, 2020, 14 (03) : 644 - 651
  • [38] Intraoperative electromyogram monitoring of the recurrent laryngeal nerve:: experience with an intralaryngeal surface electrode -: A method to reduce the risk of recurrent laryngeal nerve injury during thyroid surgery
    Horn, D
    Rötzscher, VM
    LANGENBECKS ARCHIVES OF SURGERY, 1999, 384 (04) : 392 - 395
  • [39] Intraoperative electromyogram monitoring of the recurrent laryngeal nerve: experience with an intralaryngeal surface electrode A method to reduce the risk of recurrent laryngeal nerve injury during thyroid surgery
    D. Horn
    V. M. Rötzscher
    Langenbeck's Archives of Surgery, 1999, 384 : 392 - 395
  • [40] Intraoperative monitoring of the recurrent laryngeal nerve by vagal nerve stimulation in thyroid surgery
    Brigitte Farizon
    Marie Gavid
    Alexandre Karkas
    Jean-Marc Dumollard
    Michel Peoc’h
    Jean-Michel Prades
    European Archives of Oto-Rhino-Laryngology, 2017, 274 : 421 - 426