Factors Affecting Upon the Calibration Factor of Radon Dosimeter: Theoretical and Experimental Study

被引:1
|
作者
Ashry, A. H. [1 ]
Abou-Leila, M. [1 ]
Abdalla, A. M. [1 ,2 ,3 ,4 ]
机构
[1] Ain Shams Univ, Fac Educ, Dept Phys, Cairo 11757, Egypt
[2] Najran Univ, Dept Phys, Fac Sci & Arts, Najran 11001, Saudi Arabia
[3] Najran Univ, Adv Mat & Nanoengn Lab AMNEL, Najran 11001, Saudi Arabia
[4] Najran Univ, Ctr Adv Mat & Nanoengn CAMNE, Najran 11001, Saudi Arabia
关键词
DIFFUSION-CHAMBERS DIMENSIONS; PLASTIC TRACK DETECTOR; ENVIRONMENTAL RADON; ALPHA-PARTICLES; MONTE-CARLO; CR-39; TEMPERATURE; HUMIDITY; SENSITIVITY; EFFICIENCY;
D O I
10.1166/asl.2010.1148
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The calibration factor of radon dosimeter (CR-39 track detector) for radon and its daughters has been determined theoretically and experimentally at different environmental conditions, i.e., humidity and temperature. The effect of humidity was examined practically and correlated with theoretical studies. From the detailed studies, it was observed that the theoretical value of calibration factor was larger than the experimental one at low-relative humidity condition. The effect of temperature on the calibration factor of CR-39 track detector was examined theoretically. It was found from the theoretical studies that the calibration factor increases with increasing the temperature.
引用
收藏
页码:518 / 522
页数:5
相关论文
共 50 条
  • [21] THEORETICAL AND EXPERIMENTAL INVESTIGATION OF FACTORS AFFECTING PRECISION IN MOLECULAR ABSORPTION SPECTROPHOTOMETRY
    ROTHMAN, LD
    CROUCH, SR
    INGLE, JD
    ANALYTICAL CHEMISTRY, 1975, 47 (08) : 1226 - 1233
  • [22] Theoretical and experimental factors affecting measurements of semiconductor mean inner potentials
    Pennington, R. S.
    Mortensen, J. J.
    Kasama, T.
    Boothroyd, C. B.
    Dunin-Borkowski, R. E.
    16TH INTERNATIONAL CONFERENCE ON MICROSCOPY OF SEMICONDUCTING MATERIALS, 2010, 209
  • [23] FACTORS AFFECTING COMPARISON OF THEORETICAL AND EXPERIMENTAL SOUND TRANSMISSION LOSS OF PANELS
    HOLMER, CI
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1971, 49 (01): : 88 - &
  • [24] FACTORS AFFECTING INDOOR RADON VARIATIONS: A CASE STUDY IN SCHOOLS OF EASTERN MACEDONIA
    Stojanovska, Z.
    Boev, B.
    Zunic, Z. S.
    Ivanova, K.
    Sorsa, Ajka
    Boev, I
    Curguz, Z.
    Kolarz, P.
    ROMANIAN JOURNAL OF PHYSICS, 2019, 64 (1-2):
  • [25] A calibration method free of optimism factor number selection for automated multivariate analysis. Experimental and theoretical study
    Xu, LA
    Schechter, I
    ANALYTICAL CHEMISTRY, 1997, 69 (18) : 3722 - 3730
  • [26] Experimental and theoretical study of radon levels and entry mechanisms in a Mediterranean climate house
    Font, LL
    Baixeras, C
    Domingo, C
    Fernandez, F
    RADIATION MEASUREMENTS, 1999, 31 (1-6) : 277 - 282
  • [27] Experimental and theoretical study of radon levels and entry mechanisms in a mediterranean climate house
    Grup de Fisica de Les Radiacions, Edifici Cc, Universitat Autònoma de Barcelona, E-08193 Bellaterra, Spain
    Radiat. Meas., 1 (277-282):
  • [28] In vitro study of experimental factors affecting the microdialysis results
    Martínez, MSM
    Hurtado, BG
    Gandarillas, CIC
    Lanao, JM
    Navarro, AS
    ANALYTICA CHIMICA ACTA, 2002, 459 (01) : 143 - 150
  • [29] EXPERIMENTAL STUDY OF FACTORS AFFECTING MOBILIZATION OF REVOLUTIONARY COALITIONS
    LAWLER, EJ
    SOCIOMETRY, 1975, 38 (02): : 163 - 179
  • [30] Calibration of track detectors for fission rate determination: An experimental and theoretical study
    Hashemi-Nezhad, S. R.
    Zhuk, I. V.
    Potapenko, A. S.
    Krivopustov, M. I.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 568 (02): : 816 - 825