Abdominal Aortic Aneurysm Endovascular Repair: Profiling Postimplantation Morphometry and Hemodynamics With Image-Based Computational Fluid Dynamics

被引:19
|
作者
Tasso, Paola [1 ]
Raptis, Anastasios [2 ]
Matsagkas, Mitiadis [3 ]
Rizzini, Maurizio Lodi [1 ]
Gallo, Diego [1 ]
Xenos, Michalis [4 ]
Morbiducci, Umberto [1 ]
机构
[1] Politecn Torino, Dept Mech & Aerosp Engn, I-10129 Turin, Italy
[2] Inst Vasc Dis, Lab Vasc Simulat, Ioannina 45500, Greece
[3] Univ Thessaly, Fac Med, Dept Vasc Surg, Larisa 41334, Greece
[4] Univ Ioannina, Dept Math, Ioannina 45500, Greece
关键词
HELICAL FLOW; STENT-GRAFTS; CAROTID BIFURCATION; BLOOD-FLOW; IN-VIVO; METAANALYSIS; COMPLICATIONS; TORTUOSITY; ENDOGRAFTS; CURVATURE;
D O I
10.1115/1.4040337
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Endovascular aneurysm repair (EVAR) has disseminated rapidly as an alternative to open surgical repair for the treatment of abdominal aortic aneurysms (AAAs), because of its reduced invasiveness, low mortality, and morbidity rate. The effectiveness of the endovascular devices used in EVAR is always at question as postoperative adverse events can lead to re-intervention or to a possible fatal scenario for the circulatory system. Motivated by the assessment of the risks related to thrombus formation, here the impact of two different commercial endovascular grafts on local hemodynamics is explored through 20 image-based computational hemodynamic models of EVAR-treated patients (N =10 per each endograft model). Hemodynamic features, susceptible to promote thrombus formation, such as flow separation and recirculation, are quantitatively assessed and compared with the local hemodynamics established in image-based infrarenal abdominal aortic models of healthy subjects (N =10). Moreover, the durability of endovascular devices is investigated analyzing the displacement forces (DFs) acting on them. The hemodynamic analysis is complemented by a geometrical characterization of the EVAR-induced reshaping of the infrarenal abdominal aortic vascular region. The findings of this study indicate that (1) the clinically observed propensity to thrombus formation in devices used in EVAR strategies can be explained in terms of local hemodynamics by means of image-based computational hemodynamics approach; (2) reportedly prothrombotic hemodynamic structures are strongly associated with the geometry of the aortoiliac tract postoperatively; and (3) DFs are associated with cross-sectional area of the aortoiliac tract postoperatively. In perspective, our study suggests that future clinical followup studies could include a geometric analysis of the region of the implant, monitoring shape variations that can lead to hemodynamic disturbances of clinical significance.
引用
收藏
页数:12
相关论文
共 50 条
  • [42] Thoracic endovascular aortic repair for acute aortic dissection complicated by mesenteric malperfusion: an evaluation by computational fluid dynamics
    Kimura, Naoyuki
    Imada, Shuta
    Hori, Daijiro
    Nakamura, Masanori
    INTERDISCIPLINARY CARDIOVASCULAR AND THORACIC SURGERY, 2024, 38 (03):
  • [43] Computational analysis of Nitinol stent-graft for endovascular aortic repair (EVAR) of abdominal aortic aneurysm (AAA): Crimping, sealing and fluid-structure interaction (FSI)
    Jayendiran, Raja
    Nour, Bakr
    Ruimi, Annie
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2020, 304 : 164 - 171
  • [44] Correlations of perioperative coagulopathy, fluid infusion and blood transfusions with survival prognosis in endovascular aortic repair for ruptured abdominal aortic aneurysm
    Yohei Kawatani
    Yoshitsugu Nakamura
    Hirotsugu Kurobe
    Yuji Suda
    Takaki Hori
    World Journal of Emergency Surgery, 11
  • [45] Correlations of perioperative coagulopathy, fluid infusion and blood transfusions with survival prognosis in endovascular aortic repair for ruptured abdominal aortic aneurysm
    Kawatani, Yohei
    Nakamura, Yoshitsugu
    Kurobe, Hirotsugu
    Suda, Yuji
    Hori, Takaki
    WORLD JOURNAL OF EMERGENCY SURGERY, 2016, 11
  • [46] Computational Fluid Dynamics Evaluation of the Cross-Limb Stent Graft Configuration for Endovascular Aneurysm Repair
    Shek, Tina L. T.
    Tse, Leonard W.
    Nabovati, Aydin
    Amon, Cristina H.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2012, 134 (12):
  • [47] Analysis of Stent-Graft Design for Aortic Aneurysm Repair Using Computational Fluid Dynamics
    Suess, Taylor N.
    Gent, Stephen P.
    Remund, Tyler
    Kelly, Patrick
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2015, 9 (03):
  • [48] Patient-Specific Computational Fluid Dynamics Simulations Before and After Fenestrated Endovascular Aneurysm Repair
    Lin, Wei-Chih P.
    Doyle, Matthew G.
    Amon, Cristina H.
    Forbes, Thomas L.
    JOURNAL OF VASCULAR SURGERY, 2020, 72 (01) : E263 - E263
  • [49] Feasibility of Three-Dimensional MR Angiography Image Fusion Guidance for Endovascular Abdominal Aortic Aneurysm Repair
    Tacher, Vania
    Desgranges, Pascal
    You, Ketsakin
    Ridouani, Fourat
    Marzelle, Jean
    Kobeiter, Hicham
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2016, 27 (02) : 188 - 193
  • [50] An Image-Based Computational Fluid Dynamics Study of Mitral Regurgitation in Presence of Prolapse
    Bennati, Lorenzo
    Vergara, Christian
    Giambruno, Vincenzo
    Fumagalli, Ivan
    Corno, Antonio Francesco
    Quarteroni, Alfio
    Puppini, Giovanni
    Luciani, Giovanni Battista
    CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2023, 14 (03) : 457 - 475