Quantitative 3D petrography using X-ray tomography 2: Combining information at various resolutions

被引:24
|
作者
Pamukcu, Ayla S. [1 ]
Gualda, Guilherme A. R. [1 ]
机构
[1] Vanderbilt Univ, Dept Earth & Environm Sci, Nashville, TN 37235 USA
来源
GEOSPHERE | 2010年 / 6卷 / 06期
基金
美国国家科学基金会;
关键词
CRYSTAL SIZE DISTRIBUTIONS; BISHOP-TUFF; LONG-VALLEY; MICROTOMOGRAPHY; BUBBLE; FRAGMENTATION; ERUPTIONS; INSIGHTS; SYSTEMS; GROWTH;
D O I
10.1130/GES00565.1
中图分类号
P [天文学、地球科学];
学科分类号
07 ;
摘要
X-ray tomography is a nondestructive technique that can be used to study rocks and other materials in three dimensions over a wide range of sizes. Samples that range from decimeters to micrometers in size can be analyzed, and micrometer-to centimetersized crystals, vesicles, and other particles can be identified and quantified. In many applications, quantification of a large spectrum of sizes is important, but this cannot be easily accomplished using a single tomogram due to a common trade-off between sample size and image resolution. This problem can be circumvented by combining tomograms acquired for a single sample at a variety of resolutions. We have successfully applied this method to obtain crystal size distributions (CSDs) for magnetite, pyroxene + biotite, and quartz + feldspar in Bishop Tuff pumice. Five cylinders of systematically varying size (1-10 mm diameter and height) were analyzed from each of five pumice clasts. Cylinder size is inversely proportional to image resolution, such that resolution ranges from 2.5 to 17 mu m/voxel with increasing sample size. This allows quantification of crystals 10-1000 mu m in size. We obtained CSDs for each phase in each sample by combining information from all resolutions, each size bin containing data from the resolution that best characterizes crystals of that size. CSDs for magnetite and pyroxene + biotite in late-erupted Bishop pumice obtained using this method are fractal, but do not seem to result from crystal fragmentation. CSDs for quartz + feldspar reveal a population of abundant crystals <35 mu m in size, and a population of crystals >50 mu m in size, which will be the focus of a separate publication.
引用
收藏
页码:775 / 781
页数:7
相关论文
共 50 条
  • [41] 3D characterization of sandstone by means of X-ray computed tomography
    Cnudde, V.
    Boone, M.
    Dewanckele, J.
    Dierick, M.
    Van Hoorebeke, L.
    Jacobs, P.
    GEOSPHERE, 2011, 7 (01): : 54 - 61
  • [42] Automated 3D cytoplasm segmentation in soft X-ray tomography
    Erozan, Ayse
    Loesel, Philipp D.
    Heuveline, Vincent
    Weinhardt, Venera
    ISCIENCE, 2024, 27 (06)
  • [43] Optical and X-ray computed tomography scanning of 3D dosimeters
    Jordan, K. J.
    Hilts, M.
    Jirasek, A.
    9TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY, 2017, 847
  • [44] Automated seed testing by 3D X-ray computed tomography
    Porsch, Felix
    SEED SCIENCE AND TECHNOLOGY, 2020, 48 (01) : 73 - 81
  • [45] Imaging Cancer Cells and their Interactions Within 3D Microenvironment - a Quantitative Study using Cryo Soft X-Ray Tomography
    Chen, Jian-Hua
    Ekman, Axel
    Weinhardt, Venera
    McDermott, Gerry
    Le Gros, Mark A.
    Larabell, Carolyn A.
    BIOPHYSICAL JOURNAL, 2019, 116 (03) : 439A - 439A
  • [46] New textural evidence on the origin of carbonado diamond: An example of 3-D petrography using X-ray computed tomography
    Ketcham, Richard A.
    Koeberl, Christian
    GEOSPHERE, 2013, 9 (05): : 1336 - 1347
  • [47] 2D/3D Microanalysis by Energy Dispersive X-ray Absorption Spectroscopy Tomography
    Sanchez, Dario Ferreira
    Simionovici, Alexandre S.
    Lemelle, Laurence
    Cuartero, Vera
    Mathon, Olivier
    Pascarelli, Sakura
    Bonnin, Anne
    Shapiro, Russell
    Konhauser, Kurt
    Grolimund, Daniel
    Bleuet, Pierre
    SCIENTIFIC REPORTS, 2017, 7
  • [48] 2D/3D Microanalysis by Energy Dispersive X-ray Absorption Spectroscopy Tomography
    Dario Ferreira Sanchez
    Alexandre S. Simionovici
    Laurence Lemelle
    Vera Cuartero
    Olivier Mathon
    Sakura Pascarelli
    Anne Bonnin
    Russell Shapiro
    Kurt Konhauser
    Daniel Grolimund
    Pierre Bleuet
    Scientific Reports, 7
  • [49] Failure Analysis of a Composite Rudder Stock Using 3D X-ray Microcomputed Tomography
    Nikhil K. Kar
    Adam Bovie
    Journal of Failure Analysis and Prevention, 2019, 19 : 24 - 28
  • [50] Analysis of complex structures using a 3D X-ray tomography system with microfocus tube
    Lopes, RT
    de Oliveira, LF
    de Jesus, EFO
    Brazd, D
    DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 : 213 - 221